• 제목/요약/키워드: Small Generator

검색결과 686건 처리시간 0.025초

소수력 발전용 고효율 100kW 발전기의 설계해석 및 경제성 분석 (Design Analysis and Economic Analysis of high Efficiency 100kW Generator for Hydro Power System)

  • 지인호;강승진
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.428-438
    • /
    • 2016
  • This paper shows the design of the 100 kW IPMSG for small hydraulic power generator. The high-efficient generator, method of the dual layer interior permanent magnet was studied to improve the method of the single layer interior permanent magnet, which is mostly used. Analysis of magnet arrangement and cogging torque was done by FEM. According to structure analysis of dual layer interior permanent magnet, the amount of usage of the permanent magnet was reduced and cogging torque was decreased as well. With these successful results, the high-efficient generator design was accomplished. Based on the results of the structure analysis, the test product was designed and manufactured. And the design values and performance outputs were compared and verified with success. Also, the economic feasibility was conducted based on the electric power generated from the test product installed at the site. By the B/C analysis, in case that only SMP was analyzed, B/C ratio was 1.24 at the discount ratio of 5.5%, which considered to be economically feasible. The study is expected to be used for the application of developing large scale high-efficient interior permanent magnet synchronous generator.

개선된 자동 주파수 보정회로를 이용한 광대역 클록 발생기 설계 (A Wideband Clock Generator Design using Improved Automatic Frequency Calibration Circuit)

  • 정상훈;유남희;조성익
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.451-454
    • /
    • 2011
  • In this paper, a wideband clock generator using novel Automatic frequency calibration(AFC) scheme is proposed. Wideband clock generator using AFC has the advantage of small VCO gain and wide frequency band. The conventional AFC compares whether the feedback frequency is faster or slower then the reference frequency. However, the proposed AFC can detect frequency difference between reference frequency with feedback frequency. So it can be reduced an operation time than conventional methods AFC. Conventional AFC goes to the initial code if the frequency step changed. This AFC, on the other hand, can a prior state code so it can approach a fast operation. In simulation results, the proposed clock generator is designed for DisplayPort using the CMOS ring-VCO. The VCO tuning range is 350MHz, and a VCO frequency is 270MHz. The lock time of clock generator is less then 3us at input reference frequency, 67.5MHz. The phase noise is -109dBC/Hz at 1MHz offset from the center frequency. and power consumption is 10.1mW at 1.8V supply and layout area is $0.384mm^2$.

회전코일 와전류신호를 이용한 증기발생기 곡관형 튜브의 축방향노치 신호의 특성 (Characteristics of Eddy Current Signals of Axial Notches in Steam Generator U-bend Tubes using Rotating Pancake Coils)

  • 김창수;문용식
    • 한국압력기기공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.7-12
    • /
    • 2012
  • Steam generator tubes are critical boundary of the primary and secondary side in nuclear power plants. Eddy current testing is commonly used as the method of non-destructive testing for the safety and integrity of steam generator tubes in the nuclear power plants. Changes in the geometric shape act as a stress concentration factor likely to cause a defect during the steam generator operation. The mixed-signals with the geometric shape are distorted and attributes that are difficult to detect signals. An example is bending stress due to compression process at a U-bend occurring in the intrados region which has a small radius of curvature. The resulting change in the geometric shape may lead to a dent like occurrences. The dent can cause stress concentration and generates stress corrosion cracks. In this study, the steam generator tubes of nuclear power plant were selected to study for analysis of mixed-signal containing dent and stress corrosion cracks.

발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구 (A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings)

  • 김희수;배용채;기창두
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

횡자속형 영구자석 풍력발전기의 운전특성 해석 (Performance Analysis of Axial-Flux Permanent-Magnet Synchronous Generator for Wind Power Applications)

  • 황돈하;강도현;김용주;최경호;배성우;김동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.143-145
    • /
    • 2003
  • In this paper, wind power system with direct-driven axial-flux type permanent-magnet (PM) synchronous generator, 10 [kVA], 300 [rpm], is presented. In order to analyze the performance of axial PM generator, finite-element (FE) analysis is used, and the 2-dimensional equivalent model is developed. The steady-state and transient-state characteristics are respectively analyzed at no-load and resistive-inductive loads. The test results of driving characteristics are presented as well. The results are very similar to predicted performance of design. Proposed generator is feasible for use with a small-class wind power applications.

  • PDF

저풍속/고효율 10KW급 상호역회전 풍력발전시스템 개발 및 실증실험에 관한 연구 (A Study on the Development of a 10KW Class Dual Rotor Counter-Rotating Wind Turbine Generator System with Low Wind Speed/High Efficiency and Its Field Test)

  • 허현강;장태종;김상욱
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.495-499
    • /
    • 2009
  • 본 논문에서는 상호역회전 풍력발전기와 New Yaw System 실증시험에 대하여 제시한다. 상호역회전 풍력발전기는 공기의 유동을 가진 운동에너지의 공기역학적(aerodynamic) 특성을 이용하여 동일한 바람방향에 대해 상호 반대방향으로 회전하는 Front Blade와 Rear Blade를, Generator의 Rotor와 Stator에 각각 결합 형성한 것으로, Generator와 Dual Blade의 회전력이 원심력이 아닌 구심력으로 변환되어 무게중심이 균형을 이루게 한다. 이렇게 변환된 구심력은 회전구동부분의 편마모 현상, 소음발생 현상 및 불균형 톨크 발생 현상 감소효과가 공히 구현되도록 하여 풍력발전기의 구조적 안정성 및 발전효율 증대효과를 얻을 수 있도록 한 기술이다.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.453-456
    • /
    • 2007
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

소동물 실험용 다중코일형 자계발생장치의 설계 및 성능평가 (Design and Evaluation of a Magnetic Field Generator for Biological Experiment)

  • 명성호;이재복;김상범;추장희;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 2000
  • A magnetic field generator for small animal study was designed and constructed. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was made. Using this, optimum electric current ratio and position of each coil were determined. Meanwhile, inductance of the generator was calculated for design of power supply. The field measurement results of the manufactured generator showed that the difference between maximum and minimum magnetic field at the living floor was less than 2%.

  • PDF

수차발전기 상태진단시스템을 이용한 예지보전체계 (Predictive Maintenance System using Condition Monitoring System of Hydro-turbine Generator)

  • 김응태;고성호;김현;정용채;최성필
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2006
  • The purpose of this study is to explain the importance of Vibration Monitoring Device by introducing an example of Predictive Maintenance System using Condition Monitoring System of Hydro-turbine generator. Confirming vibration of generation equipment is commissioning procedure during equipment completion for checking guaranteed items. Data from Generator output range are used to determine output band to continue the performance of equipment. The Vibration Monitoring System is not absolute method of maintenance, but if it is used well with expert, it will be visible, data-analyzed, scientific maintenance more than others. And also, Condition Monitoring System is very important for remote controlled small hydro-power plant although most of it is installed in Large hydro-power plant.

  • PDF

유압 구동식 발전장치의 정주파수 제어 - 시뮬레이션 - (Constant Frequency Control of Generating System Driven by Hydraulic Power - Simulation -)

  • 정용길;오인호
    • 수산해양기술연구
    • /
    • 제26권3호
    • /
    • pp.275-281
    • /
    • 1990
  • This study suggests a new type shaft generator driven by hydraulic power suitable for small size vessels. Since the shaft generator system is very easy to be affected by disturbances such as speed variation of the main engine and the load variation of the generator, a robust servo control must be performed to obtain stable electric power with constant frequency. So, in this study the robust servo control method is adopted to the controller design. Dynamic characteristics on the frequency variations of the electric power output according to the disturbances are investigated by computer simulations. From the considerations of the computer simulation results, it is ascertained that the shaft generator system proposed in this study had good control performances.

  • PDF