• Title/Summary/Keyword: Small Diameter Tube

Search Result 188, Processing Time 0.033 seconds

Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures (캡슐 하단부 구조변경에 따른 압력강하 및 진동특성)

  • Choi, M.H.;Choo, K.N.;Cho, M.S.;Lee, K.H.;Kim, B.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.782-787
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change or the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural Integrity of the material capsule called 04M-l7U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19 6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's In-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

  • PDF

Fabrication of nano-structured PMMA substrates for the improvement of the optical transmittance (반구형 나노 패턴의 크기에 따른 PMMA기판의 광특성 평가)

  • Park, Y.M.;Shin, H.G.;Kim, B.H.;Seo, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.217-220
    • /
    • 2009
  • This paper presents fabrication method of nano-structured PMMA substrates as well as evaluations of their optical transmittance. For anti-reflective surface, surface coating method had been conventionally used. However, it requires high cost, complicated process and post-processing times. In this study, we suggested the fabrication method of anti-reflective surface by the hot embossing process. Using the nano patterned master fabricated by anodic aluminum oxidation process. Anodic aluminum oxide(AAO) is widely used as templates or a molds for various applications such as carbon nano tube (CNT), nano rod and nano dots. Anodic aluminum oxidation process provides highly ordered regular nano-structures on the large area, while conventional pattering methods such as E-beam and FIB can fabricate arbitrary nano-structures on small area. We fabricated a porous alumina hole array with various inter-pore distance and pore diameter. In order to replicate nano-structures using alumina nano hole array patterns, we have carried out hot-embossing process with PMMA substrates. Finally the nano-structured PMMA substrates were fabricated and their optical transmittances were measured in order to evaluate the charateristivs of anti-reflection. Anti-reflective structure can be applied to various displays and automobile components.

  • PDF

Carbon Monoxide Emission and Radiation Properties in Ceramic Fiber Radiant Burner (세라믹 화이버 버너의 CO 배출과 복사강도 특성)

  • Jeong, Yong-Ki;Kim, Young-Soo;Lee, Dae-Rae;Yang, Dae-Bong;Ryu, Jung-Wan;Yun, Alexander;Chang, Young-June;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.176-183
    • /
    • 2007
  • An experimental study was performed to investigate the effects of mixing quality, inlet pressure, nozzle diameter on CO emission and radiation characteristics in porous ceramic fiber radiant burners. Observations of combustion characteristics occurring inside the burner system which was insulated fiber mat, were investigated by measuring temperature, CO emission and radiation characteristics. Combustion was achieved at the firing rate of $88{\sim}99$ kcal/hr, inlet pressure of $100{\sim}250$mm$H_2O$. CO emissions were found to be strongly dependent on the operating conditions. There was a tendency that CO concentration increased as the firing rate increases. The reason for rise of CO concentration is that it becomes the relatively rich condition. The fiber burner exhibit significant both spectral intensity peaks in the bands at 2.5${\mu}m$ and 4.0${\mu}m$ relatively, There is a small difference in the variable mixing tube. However spectral intensity increased with the firing rate.

  • PDF

The characteristics of suction pressure by throttle opening of the carburetor dummy at steady state (정상상태에서 카뷰레터 더미모델의 스로틀 개도에 따른 압력특성)

  • Cho, Hyoung-Mun;Kim, Byeong-Guk;Choi, Young-Ha;Yoon, Suck-Ju;Han, Jong-Kyu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.711-714
    • /
    • 2008
  • The objective of this paper is to know the characteristics of pressure through a simplified typical carburetor used in small engines at the different throttle opening conditions. The carburetor is the device responsible for creating the right air-fuel mixture according to the different engine operating conditions. It is activated by the static or the dynamic pressure. The carburetor dummy is geometrically similar of LPG brush-cutter engine's diaphragm carburetor and is made of acrylic. Suction system gives body to crankcase vacuum using the vacuum pump and throttle opening conditions are controled by transfer device. Carburetor venturi throat and fuel charging tube diameter is each 20mm, 4.1mm. The result of the work presents an unprecedented phenomenon of suction pressure variation inside the carburetor venturi. It is predicted that these unprecedented pressure variation be caused by minor losses; sudden contraction or expansion, open or partially closed and so on.

  • PDF

Simulation of Water/steam into Sodium Leak Behavior for an Acoustic Noise Generation Mechanism Study

  • Kim, Tae-Joon;Hwang, Sung-Tai;Jeong, Kyung-Chai;Park, Jong-Hyeun;Valery S. Yughay
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2001
  • This simulation first allows us to define a transition zone from a bubble to jet mode of the argon out-flow and hereinafter to define a similar area for water-steam leak in the KALIMER SG (Korea Advanced Liquid Metal Reactor Steam Generator) using a water mock-up system, taking into account the KALIMER leak classification and tube bundle design, as a simulation of a real water-steam into sodium leak. in accordance with leak conditions in the KALIMER SG, the transition from bubbling to jetting is studied by means of turbulence regime simulation for argon out-flow through a very small orifice, which has the equivalent diameter of about 0.253 mm. finally the noise generation mechanism is explained from the existing experimental data. We also confirmed the possibility of micro-leak detection from the information of the bubbling mode through simulations and the experiment in this study.

  • PDF

A Study on the Flow Characteristics of Circular and Swirl Jets (원형 및 스월제트의 유동특성에 관한 연구)

  • Ko, Dong Guk;Yoon, Suck Ju
    • Journal of ILASS-Korea
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2014
  • The comparison of the flow characteristics between circular and swirl jets which were controlled by the spinner attachment inside the airtube were conducted in this study. Swirl jet means a flow in whirls by mixing the flow of axial and tangential direction. Swirl flow has been used for the improvement of the combustion efficiency in the combustor. This flow is controlled by the spinner which has several vanes inclined by certain angles to the axial direction. In this study, angle of vane $30^{\circ}$ and diameter ratio of outlet to inlet of the airtube 0.73 were made. These spec. should find on the general gun type burner built in the domestic small size boiler. As the flow characteristics, axial and tangential velocities were measured by using the 2-D hot-wire velocimeter system and analyzed statistically. And also this research conducted a practical experiment considering to the attached belongings likes as ignitor, nozzle etc. on the airtube of the gun type burner. As a result, swirl occurred at the occasion of beingness and flow region extended considerably toward the radial direction. But effect of swirl did not transmit to the downstream. And the complicated flow was appeared regardless of the existence of spinner because of the effect of belongings.

Numerical Analysis of MDF for Aluminum Plate Cutting (MDF를 이용한 알루미늄 평판 절개 해석)

  • Lee, Juho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.134-141
    • /
    • 2018
  • In this paper, the possibility of using an MDF (Mild-detonating Fuse) as a linear separation device is studied. An MDF is a small diameter metal (lead) tube filled with explosives (RDX). Aluminum plate cutting experiments are carried out with different values of target plate thickness and explosives per unit length. Based on the experimental results, a numerical analysis method including the failure criteria is established. The mechanism and characteristics of using MDFs for aluminum plate cutting are identified; the possibility of using the current system as a linear separation device is verified. By utilizing a developed numerical method, the separation reliability for diverse structures and MDFs can be predicted in advance and the number of experiments required for development can be minimized.

Service ability design of vibrating chiral SWCNTs: Validation and parametric study

  • Muzamal Hussain;Mohamed R. Ali;Abdelhakim Benslimane;Humaira Sharif;Mohamed A. Khadimallah;Muhammad Nawaz Naeem;Imene Harbaoui;Sofiene Helaili;Aqib Majeed;Abdelouahed Tounsi
    • Computers and Concrete
    • /
    • v.32 no.4
    • /
    • pp.393-398
    • /
    • 2023
  • This paper provides the free vibrations of chiral carbon nanotubes. The governing equations of Flügge theory is considered for vibration frequencies of chiral single walled carbon nanotubes. The solution of frequency equation is obtained from a novel model for better representation of stubby and short vibration characteristics of chiral tubes with clamped-clamped and clamped-simply supported end conditions. For the harmonic response of this tube, the model displacement function is adopted. The variational approach Rayleigh-Ritz method with kinetic and strain energies are used. The Lagragian function is differentiated with respect to unknown functions. The frequency equation is written in compact form to solve with MATLAB software. The frequencies of chiral SWCNTs for first ten aspect ratios as small level are investigated. The results shown as for decreasing the aspect rations, the frequencies are increases. The presented results of this model are verified with experimental and numerical results, which found as an excellent agreement.

Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes (세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • An experimental study to investigate the condensing heat transfer characteristics of small diameter horizontal double pipe heat exchangers with R-22 and R-410A was performed. Experimental facility was constructed to calculate and observe HTC(heat transfer coefficients), flow patterns and pressure drop. The main components include a liquid pump, an evaporator, a condenser(test section), a sight-glass, pressure taps and measurement apparatus. Two pipes of different diameters are tested; One 5.35 mm ID 0.5 mm thick, the other 3.36 mm ID 0.7 mm thick. The mass flow rate ranged from 200 to $500\;ks/m^2{\cdot}s$ and heating capacity were form 1.0 to 2.4 kW. The flow patterns of R-22 and R-410A were observed with a high speed camera through the sight-glass. The tests revealed that HTC of R-410A was higher than that of R-22 by maximum 5%. Annular pattern was observed for the most cases but stratified flow was also detected when x<0.2. The pressure drop in 3.36 mm ID pipe was higher than that of 5.35 mm by $30{\sim}50%$. Comparing with previous correlations such as Shah, Fujii and Soliman's, Fujii' showed the best good agreement with my data with a maximum deviation of 40%.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF