• Title/Summary/Keyword: Small Bore

Search Result 76, Processing Time 0.02 seconds

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-1) (지하수류가 밀폐형 천공 지중열교환기 성능에 미치는 영향(1))

  • Hahn, Jeong Sang;Hahn, Chan;Yoon, Yun Sang;Kiem, Young Seek
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.64-81
    • /
    • 2016
  • To analyze the influence of various groundwater flow rates (specific discharge) on BHE system with balanced and unbalanced energy loads under assuming same initial temperature (15℃) of ground and groundwater, numerical modeling using FEFLOW was used for this study. When groundwater flow is increased from 1 × 10−7 to 4 × 10−7m/s under balanced energy load, the performance of BHE system is improved about 26.7% in summer and 22.7% at winter time in a single BHE case as well as about 12.0~18.6% in summer and 7.6~8.7% in winter time depending on the number of boreholes in the grid, their array type, and bore hole separation in multiple BHE system case. In other words, the performance of BHE system is improved due to lower avT in summer and higher avT in winter time when groundwater flow becomes larger. On the contrary it is decreased owing to higher avT in summer and lower avT in winter time when the numbers of BHEs in an array are increased, Geothermal plume created at down-gradient area by groundwater flow is relatively small in balanced load condition while quite large in unbalanced load condition. Groundwater flow enhances in general the thermal efficiency by transferring heat away from the BHEs. Therefore it is highly required to obtain and to use adequate informations on hydrogeologic characterristics (K, S, hydraulic gradient, seasonal variation of groundwater temperature and water level) along with integrating groundwater flow and also hydrogeothermal properties (thermal conductivity, seasonal variation of ground temperatures etc.) of the relevant area for achieving the optimal design of BHE system.

Weight Reduction of an Urban Railway Axle Based on EN Standard (EN 규격에 기반한 도시철도차량 차축의 경량화)

  • Han, Soon-Woo;Son, Seung-Wan;Jung, Hyun-Seung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.579-590
    • /
    • 2012
  • Weight reduction of a railway axle, which is one of heaviest parts in an urban railway vehicle, is discussed in this paper. A wheelset of a railway vehicle is very important with regard to railway safety, and its structural strength should always be considered when attempting to reduce the railway axle weight. In this work, the weight of the axles of a trailer bogie and a motor bogie of the Korean EMU was reduced by replacing solid axles with hollow axles. On the basis of the EN standard for railway axle design, the strength of existing solid axles was analyzed and the required bore size of a hollow axle was determined. It is shown that the weight of the concurrent axle of the Korean EMU can be reduced by up to 20% with a very small decrease in the structural strength. Finite element analyses were also carried out to verify the design result for lightweight hollow axles.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(5)-Effect of Evaluation Position (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(5) - 평가위치의 영향)

  • Cho, Siehyung;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.179-189
    • /
    • 2017
  • This paper is the fifth investigation on the methods of evaluating flow characteristics in a steady flow bench. In previous studies, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation may lead to serious problems. In addition, though the velocity profiles were improved as the measuring position went downstream, the distributions were far from ideal regardless of the valve angle and evaluation position. The eccentricities were also not sufficiently small to disregard the effect on impulse swirl meter (ISM) measurement. Therefore, the effect of these distribution and eccentricity changes according to the positions needs to be analyzed to discuss the method of flow characteristics estimation. In this context, the effects of evaluation position on the steady flow characteristics were studied. For this purpose, the swirl coefficient and swirl ratio were assessed and compared via measurement of the conventional ISM and calculation based on the velocity by particle image velocimetry(PIV) from 1.75B, 1.75 times bore position apart from the cylinder head, to the 6.00B position. The results show that the swirl coefficients by ISM strictly decrease and the curves as a function of the valve lift become smooth and linear as the measuring position goes downstream. However, the values through the calculation based on the PIV are higher at the farther position due to the approach of the tangential velocity profile to ideal. In addition, there exists an offset effect between the velocity distribution and eccentricity in the low valve lift range when the coefficients are estimated based on the swirl center. Finally, the curve of the swirl ratio by ISM and by PIV evaluation as a function the measuring position intersect around 5.00B plane except at $26^{\circ}$ valve angle.

Thrust and Aerodynamic Load Characteristics of an Internal Pintle Thruster (노즐 목 내부형 핀틀추력기의 추력 및 공력하중 특성)

  • Choi, Junsub;Kim, Dongyeon;Huh, Hwanil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.1-9
    • /
    • 2017
  • Numerical computations are performed to investigate the effect of pintle stroke on the performance of an internal pintle thruster. Results show that the thrust control ratio was less than 2% and the aerodynamic load ratio was 22% as the pintle stroke increased. The flow past the nozzle throat rapidly expanding because of the shape of the pintle, and a shock wave was generated. Particularly, at the pintle stroke distance of 4 and 5 mm, the shock wave hit the wall of the nozzle, results in peeling bubbles. Depending on the altitude, the thrust increased and the aerodynamic load decreased, but the difference was as small as 1.5%. In the presence of the bore, the reduction of the pintle tip area resulted in a decrease in aerodynamic load.

Hazard Distance from Hydrogen Accidents (수소가스사고의 피해범위)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • An analysis was completed of the hazards distance of hydrogen accidents such as jet release, jet fire, and vapor cloud explosion(VCE) of hydrogen gas, and simplified equations have been proposed to predict the hazard distances to set up safety distance by the gas dispersion, fire, and explosion following hydrogen gas release. For a small release rate of hydrogen gas, such as from a pine-hole, the hazard distance from jet dispersion is longer than that from jet fire. The hazard distance is directly proportional to the pressure raised to a half power and to the diameter of hole and up to several tens meters. For a large release rate, such as from full bore rupture of a pipeline or a large hole of storage vessel, the hazard distance from a large jet fire is longer than that from unconfined vapor cloud explosion. The hazard distance from the fire may be up to several hundred meters. Hydrogen filling station in urban area is difficult to compliance with the safety distance criterion, if the accident scenario of large hydrogen gas release is basis for setting up the safety distance, which is minimum separation distance between the station and building. Therefore, the accident of large hydrogen gas release must be prevented by using safety devices and the safety distance may be set based on the small release rate of hydrogen gas. But if there are any possibility of large release, populated building, such as school, hospital etc, should be separated several hundred meters.

Target dose study of effects of changes in the AAA Calculation resolution on Lung SABR plan (Lung SABR plan시 AAA의 Calculation resolution 변화에 의한 Target dose 영향 연구)

  • Kim, Dae Il;Son, Sang Jun;Ahn, Bum Seok;Jung, Chi Hoon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.171-176
    • /
    • 2014
  • Purpose : Changing the calculation grid of AAA in Lung SABR plan and to analyze the changes in target dose, and investigated the effects associated with it, and considered a suitable method of application. Materials and Methods : 4D CT image that was used to plan all been taken with Brilliance Big Bore CT (Philips, Netherlands) and in Lung SABR plan($Eclipse^{TM}$ ver10.0.42, Varian, the USA), use anisotropic analytic algorithm(AAA, ver.10, Varian Medical Systems, Palo Alto, CA, USA) and, was calculated by the calculation grid 1.0, 3.0, 5.0 mm in each Lung SABR plan. Results : Lung SABR plan of 10 cases are using each of 1.0 mm, 3.0 mm, 5.0 mm calculation grid, and in case of use a 1.0 mm calculation grid $V_{98}$. of the prescribed dose is about $99.5%{\pm}1.5%$, $D_{min}$ of the prescribed dose is about $92.5{\pm}1.5%$ and Homogeneity Index(HI) is $1.0489{\pm}0.0025$. In the case of use a 3.0 mm calculation grid $V_{98}$ dose of the prescribed dose is about $90{\pm}4.5%$, $D_{min}$ of the prescribed dose is about $87.5{\pm}3%$ and HI is about $1.07{\pm}1$. In the case of use a 5.0 mm calculation grid $V_{98}$ dose of the prescribed dose is about $63{\pm}15%$, $D_{min}$ of the prescribed dose is about $83{\pm}4%$ and HI is about $1.13{\pm}0.2$, respectively. Conclusion : The calculation grid of 1.0 mm is better improves the accuracy of dose calculation than using 3.0 mm and 5.0 mm, although calculation times increase in the case of smaller PTV relatively. As lung, spread relatively large and low density and small PTV, it is considered and good to use a calculation grid of 1.0 mm.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Clinical Efficacy of 7-French Catheter for Initial Treatment of Primary Spontaneous Pneumothorax (원발성 자연기흉에 대한 초 치료로서 7-French 흉관의 적용)

  • Ryu Kyoung-Min;Jung Eui-Seok;Cho Suk-Ki;Sung Sook-Whan;Jheon Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.394-398
    • /
    • 2006
  • Background: Goal of the initial treatment of primary spontaneous pneumothorax is re-expansion of the lung by evacuation of air from pleural space. Authors thought small caliber catheter could reach to this goal instead of conventional large bore chest tube. This retrospective study was undertaken to assess the effectiveness of 7-French (Fr) catheter for the initial treatment of primary spontaneous pneumothorax. Material and Method: Between May 2003 and April 2005, 111 patients with primary spontaneous pneumothorax were managed with tube drainage; 7 Fr catheter for 86 patients and 24-French chest tube for 25 patients. We analyzed catheter indwelling time, use of analgesics, re-expansion of the lung, and catheter related problems by medical records. Result: Mean catheter indwelling time was $2.4{\pm}1.1$ days in 7 Fr group and $2.3{\pm}1.3$ days in chest tube group (p>0.05). All patients with 24 Fr catheter needed analgesics injection but never in 7Fr group. Complete re-expansion of the lung based on plane chest radiograph was obtained in 77% of 7 Fr group. The problem related with 7 Fr catheter was kinking, which showed in 5.6%. Conclusion: Application of the 7 Fr catheter for initial management of primary spontaneous pneumothorax was as effective as 24 Fr catheter.

Simple Semiquantitative Determination and Selective Preconcentration of Trace Heavy Metals in Environmental Pollutants : Determination of Chromium (VI) with DPC Gel (環境汚染 重金屬의 選擇的 濃縮 및 簡易分析法 : DPC 겔의 의한 크롬 (VI) 의 定量)

  • Yong Keun Lee;Kyu Ja Whang;In Hwa Woo
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.275-282
    • /
    • 1981
  • A simple semiquantitative procedure was developed for the determination of sub-ppm level of chromium(VI) in aquatic samples by using an analytical micro-column packed with diphenylcarbazide(DPC) gel beads. DPC gel beads were prepared by swelling XAD-2 resin(115∼150 mesh in dry condition) in ethanol for 10min, packing into a glass column(1.5 mm bore, 65nm length) and adsorbing 1ml of ethanol solution of $2{\times}10^{-3}M$ DPC for 20min at room temperature. When 0.5ml of ethanol solution containing chromium(VI) was passed through the DPC gel column for 40min, the original white color of the reagent gel turned to red-violet from the up-stream of the column. As the length of colored band was proportional to the total amount of chromium(VI) in the sample solution passed through the column, the concentration of chromium(VI) could be determined from the calibration line which had been prepared by using the standard solution. Chromium(VI) ion as small as from 0.1 to 0.8 ppm could be determined with ${\pm}5{\sim}{\pm}15{\%}$ relative errors. Since other interfering cations were few, 100-fold excess of Fe(III), 50-fold excess of Cu(II) could be masked with EDTA. This method was successfully applied to the analysis of chromium(VI) in industrial effluents.

  • PDF

Wood Anatomical Characteristics of Domestic Red Pine (Pinus densiflora) Infested by Pine wood Nematode (Bursaphelenchus xylophilus) (소나무재선충 감염 소나무의 목재해부학적 특성)

  • Ahn, Sye-Hee;Jeon, Mun-Jang;Eom, Young-Geun;Oh, Sei-Chang;Lee, Mi-Rim
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.15-20
    • /
    • 2011
  • The pine wilt disease is one of the most serious forest diseases that kill the pine trees, and the study on the invasion and movement of the pine wood nematode within the tree is very important for understanding the inhabitation of pine wood nematode. In this relation, the microscopic observation was carried out to study the place of inhabitation and movement of pine wood nematode within the infested wood. In result, the rays were mainly infested by pine wood nematode and showed dark discoloration due to their necrosis in cross, radial and tangential surface. Also, the intensive damage was found in the resin canals. On the other hand, some traumatic resin canals in tangential band were identified in the sapwood near the cambium. In the ray, the pine wood nematode occurred more commonly in the ray parenchyma cell and fusiform ray with horizontal resin canal than in the ray tracheid and uniseriate ray without horizontal resin canal, respectively. The pine wood nematode was thought to move from ray to tracheid through the large natural opening, window-like pit, in the cross-field, neither through the small natural opening, bordered pit, in the tracheid nor through the tracheid wall by creating a bore hole.