Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment (중·소규모 생활오수 처리를 위한 합병정화조 개발)

  • Rim, Jay-Myoung;Han, Dong-Joon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

Municipal Wastewater Treatment by Submerged Membrane Process (침지형 membrane을 이용한 생활오수처리)

  • 김광남;정순형;정우영;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 1999
  • The removal characteristic of BOD, COD,T-N, and T-P was investigated in municipal wastewater treatment with anoxic and membrane submerged aerobic reactor. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 90 days operation. BOD and COD loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained.In the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 99% respectively.It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

Color Removal of Real Textile Wastewater by Sequential Anaerobic and Aerobic Reactors

  • Oh You-Kwan;Kim Yu-Jin;Ahn Yeonghee;Song Seung-Koo;Park Sunghoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.419-422
    • /
    • 2004
  • Textile wastewater from the Pusan Dyeing Industrial Complex (PDIC) was treated utilizing a two-stage continuous system, composed of an upflow anaerobic sludge blanket reactor and an activated Sludge reactor. The effects of color and organic leading rates were studied by varying the hydraulic retention time and influent glucose concentration. The maximum color load to Satisfy the legal discharge limit of color intensity in Korea (400 ADMI, unit of the American Dye Manufacturers Institute) was estimated to be 2,700 $ADMI{\cdot}L^{-1}\;day^{-1}$. This study Indicates that the two-stage anaerobic/aerobic reaction system is potentially useful in the treatment of textile wastewater.

Application of SMBR process in food wastewater advanced treatment (SMBR을 이용한 음식폐수의 고도처리)

  • 윤용수;강광남;정순형
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Submerged Membrane Bio-Reacter(SMBR) process was used to food wastewater treatment. From laboratory pilot-scale experiment data, it was confirmed that this process was very effective process for organics, suspended solid, and N, P treatment. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 150 days operation. Organics loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained. IN the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 95%, respectively. It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

MEMBRANE FORLING MECHANIMS IN MEMBRANE-COUPLES ANAEROBIC BIOREACTOR

  • Choo, Kwang-Ho;Lee, Chung-Hak
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.41-41
    • /
    • 1993
  • Recently, the advanced membrane separation technology has even been applied to the post treatment to biological process of wastewater treatment, since the efficiency of biological treatment significantly depends on maintaining a high biomass concentration in the bioreator. Particularly, anaerobic microbes in the biological system have slower growth rates than aerobic microbes and thus it takes a long hydaulic retention time(HRT) to prevent biomass washout in the completely mixed anaerobic digester. The anaerobic sludge also has poor settleability owing to its diffusible and somewhat filamentous nature. Moreover, the residual gasification and consequent sludge rise in the clarifier compartment become a considerable problem, which proves that complete separation of biological solids is difficult.

  • PDF

Effect of trace oxygen on H2S removal in anaerobic digestion (혐기소화 시 미량 산소가 H2S 제거에 미치는 영향)

  • Jo, Eun-Young;Park, Kwang-Su;Ahn, Johng-Hwa
    • Journal of Industrial Technology
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2019
  • This work experimentally determined the effect of microaerobic condition on anaerobic digestion of thickened waste activated sludge in semi-continuous mesophilic digesters at hydraulic retention time of 20 days. The concentration of hydrogen sulfide was $7{\pm}2ppm$ at the microaerobic condition and $14{\pm}2ppm$ at the anaerobic condition. Removal efficiency of volatile solid was not significantly different between microaerobic ($40{\pm}8%$) and anaerobic ($38{\pm}8%$) conditions. There was no important difference between microaerobic ($1,352{\pm}98ml/d$) and anaerobic ($1,362{\pm}104ml/d$) conditions in the biogas production, either. Therefore, it could be concluded that the application of the microaerobic condition was an efficient method of the hydrogen sulfide removal from the biogas.

Study on Sludge Reduction by Sludge Solubilization and Change of Operation Conditions of Sewage Treatment Process (하수슬러지 가용화와 하수처리 운전조건 개선을 통한 하수슬러지 발생저감 연구)

  • Choi, In-Su;Jung, Hoe-Suk;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1113-1122
    • /
    • 2009
  • In order to find the way to solve the problem of sewage sludge discharge into the ocean, the sludge solubilization by ultrasonic and the improvement methods of wastewater treatment process were studied. In the membrane bioreactor the sludge retention time was stepwise increased from 5.1 day to 442 days where the biomass average concentration has been increased from $c_B$=3.4 $gTSSL^{-1}$ to $c_B$=14.5 $gTSSL^{-1}$ respectively. At the same time, the biomass yield coefficients were reduced from 0.5-0.7 at SRT=5.1 day to 0.005-0.007 at SRT=442 days which means the reduction of sludge production. Oxygen mass transfer coefficients and ${\alpha}$-factor were investigated with changing stirrer speed to find the relation between the high biomass concentration and aeration efficiency in the propeller loop reactor. As a result of sludge solubilization, the solubilization of sludge by ultrasound was increased with increasing energy input and it led to improved anaerobic digestion rate with more biogas production than that of nonsolubilized sewage sludge.

Lithoautotrophic Nitrogen Removal from Ammonium-rich Wastewater in Aerobic Upflow Sludge Bed(AUSB) Reactor (호기성 상향류 슬러지상 반응조를 이용한 고농도 암모늄 함유폐수의 독립영양 질소제거)

  • Ahn, Young-Ho;Choi, Hoon-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.852-859
    • /
    • 2006
  • The novel microbial process such as Anammox(anaerobic ammonium oxidation) and Canon(completely autotrophic nitrogen removal over nitrite) processes is promising biotechnology to remove nitrogen from ammonium-rich wastewater like anaerobic sludge digester liquid. In this research, a new Canon-type nitrogen removal process adopting upflow granular sludge bed type configuration was investigated on its feasibility and process performance, using synthetic wastewater and sludge digester liquids. Air as an oxygen source was provided in an external aeration chamber with flow recirculation. In the first experiment using the synthetic wastewater(up to 110 mg $NH_4$-N $L^{-1}$), the ammonium removal was about 95%(92% for T-N) at effective hydraulic retention time(HRT) for 3.8 days. In the second experiment using the sludge digester liquids($438{\pm}26$ mg $NH_4$-N $L^{-1}$), the total nitrogen removal was $94{\pm}1.7%$ at HRT for 5.4 days and $76{\pm}1.5%$ at HRT for 3.8 days, respectively. Little nitrite and nitrate were observed in the effluent of both experiments. The process revealed quite a lower oxygen($0.29{\sim}0.59$ g $O_2$ $g^{-1}N$) and less alkalinity($3.1{\sim}3.4$ g $CaCO_3$ $g^{-1}N$) consumption as compared to other new technology in microbial nitrogen removal. The process also offers the economical compact reactor configuration with excellent biomass retention, resulting in lower cost for investment and maintenance.

Phosphorus Removal from Domestic Sewage by Electrolysis with Aluminium Electrodes (알루미늄의 전기분해를 이용한 오수 중의 인 제거)

  • Cheong, Kyung-Hoon;Choi, Hyung-Il;Jung, Oh-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.70-76
    • /
    • 1999
  • A laboratory experiment was performed to investigate the phosphorus removal using the activated sludge-electrolysis reactor which consisted of A$^2$/O system and aluminium electrodes as cathode and anode. In this system, the phosphorus was removed by aluminium ion, which was eluted from aluminiumelectrodes by electrolysis. In the batch experiments, when the current densities were 0.026, 0.052 and 0.08 A/dm$^2$, the phosphorus removal efficiencies for synthetic sewage were 66.4, 86.4 and 98.7% respectively. These results showed that the phosphorus removal efficiency increased with the increase of the current density. When the current values were 13, 26 and 40 mA respectively, the amounts of Al$^{3+}$ eluted from electrodes according to Faraday's law were 0.049, 0.07 and 0.12 g and Al/P mole ratio were 1.1, 2.0 and 3.41. In the continuous experiments, As hydraulic retention time(HRT) increased, COD and total nitrogen(T-N) removal efficiencies for domestic sewage increased. The average phosphorus removal rates of the activated sludge-electrolysis system were 97, 91, 80 and 80% at the HRT of 48, 24, 18 and 12 hours, respectively. Especially, the phosphorus removal rate in the activated sludge system with aluminium electrodes was higher than that in the system without aluminium electrodes.

  • PDF

Kinetic Analysis for Paper-mill Wastewater Treatment Using Pure Oxygen Activated Sludge Process (순산소 활성오니공정을 이용한 제지폐수처리의 동력학적 해석)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2000
  • An experimental study was conducted to evaluate the treatment efficiency of paper-mill wastewater using pure oxygen activated sludge process. Effects of hydraulic retention time (HRT) and organic loading on process performance and kinetics were investigated. The raw paper-mill wastewater(BOD concentration ${\leq}500mg/L$) and the effluent from dissolved air flotation(DAF) treatment(BOD concentration ${\geq}500mg/L$) were used as influent for pure oxygen activated sludge process. Average BOD removal efficiencies were above 89.3% under 6hours or longer of HRT, while under 3hours of HRT they decreased to about 82%. With the effluent from DAF process, the half saturation constants($K_S$) and the maximum specific substrate removal rate($K_{max}$) were 85 mg/L and 2.25 L/day, respectively. However, with the raw paper-mill wastewater, both $K_S$ and $K_{max}$ increased to 156 mg/L and 3.84 L/day, respectively. The microbial yield coefficient(Y) and the decay coefficient($K_d$) were 0.46 gVSS/gBOD and 0.03 L/day, respectively, with effluent from DAF process. While, Y and $K_d$ were 0.24 gVSS/gBOD and 0.035 L/day, respectively, with the raw paper-mill wastewater.

  • PDF