• Title/Summary/Keyword: Sludge Amount

Search Result 433, Processing Time 0.025 seconds

Selection of coagulant using jar test and analytic hierarchy process: A case study of Mazandaran textile wastewater

  • Asadollahfardi, Gholamreza;Zangooei, Hossein;Motamedi, Vahid;Davoodi, Mostafa
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • Textile factories are one of the industries which its wastewater treatment is a challenging issue, especially in developing countries and a conventional treatment cannot treat all its pollutants properly. Using chemical coagulants is a technique for physical and chemical primary treatment of the wastewater. We applied jar test for selection of suitable coagulant among the five coagulants including alum, calcium hydroxide, ferrous sulfate, ferrous chloride and barium chloride for the effluent of wastewater in Mazandran textile factory located in Mazandran Province, Iran. In addition, jar test, we also used analytic hierarchy process (AHP) method considering criteria which included coagulation cost, sensitivity to pH change, the amount of sludge generation and side effects for coagulation. The results of the jar test indicated that calcium hydroxide was proper among the coagulants which it removed 92.9% total suspended solid (TSS), 70% dye and 30% chemical oxygen demand. The AHP analysis presented that calcium hydroxide is more suitable than other coagulants considering five criteria.

Relationship between Energy Consumption and Operational Variables at Wastewater Treatment Plant (상관분석 및 의사결정나무분석을 통한 하수처리시설의 에너지 소비량과 운영인자의 관계 분석)

  • Jung, Yong-Jun;Kim, Ye-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.253-260
    • /
    • 2016
  • To reduce energy consumption in wastewater treatment plants (WWTPs), renewable energy applications such as small hydropower, solar energy, and wind energy are popular. However, it should be noticed that energy originated from operation of wastewater treatment process can be reduced through optimized operation based on analysis of factors affecting energy. In this research, the relationship to the various operational variables and influent factors was explored using correlation analysis and decision tree algorithm. Due to the non-linear characteristics of the process, it was difficult to find clear linear patterns through correlation analysis. However, decision tree algorithm showed its usefulness in uncovering hidden patterns that consume energy. As operational factors, influent flowrate, the amount of aeration, nitrate recycling pumping rate, and sludge wasting pumping rate were selected as important factors. For environmental factors associated with influent compositions and removal rate, BOD and T-N removal rate were selected as significant factors.

WASTE MANAGEMENT IN DECOMMISSIONING PROJECTS AT KAERI

  • Hong Sang-Bum;Park Jin-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.290-299
    • /
    • 2005
  • Two decommissioning projects are carried out at the KAERI (Korean Atomic Energy Research Institute), one for the Korea research reactors, KRR-1 and KRR-2, and another for the uranium conversion plant (UCP). The concept of the management of the wastes from the decommissioning sites was reviewed with a relation of the decommissioning strategies, technologies for the treatment and the decontamination, and the characteristics of waste. All the liquid waste generated from KRR-1 and KRR-2 decommissioning site is evaporated by a solar evaporation facility and all the liquid waste from the UCP is treated together with lagoon sludge waste. The solid wastes from the decommissioning sites are categorized into three groups; not contaminated, restricted releasable and radioactive waste. The not-contaminated waste will be reused and/or disposed at an industrial disposal site, and the releasable waste is stored for the future disposal at the KAERI. The radioactive waste is packed in containers, and will be stored at the decommissioning sites till they are sent to a national repository site. The reduction of the radioactive solid waste is one of the strategies for the decommissioning projects and could be achieved by the repeated decontamination. By the achievement of the minimization strategy, the amount of radioactive waste was reduced and the disposal cost will be reduced, but the cost for manpower, for direct materials and for administration was increased.

  • PDF

Delayed Clinical Symptoms of Gallbladder Rupture by Gallbladder Mucocele in a Dog (담낭 점액낭종에 의한 담낭 파열의 만성 경과 증례)

  • Noh, Daji;Kwon, Youngsam;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.58-61
    • /
    • 2016
  • An 11-year-old, intact male Cocker Spaniel dog was presented with history of abdominal distension, dyspnea for 10 days and lethargy for 1 day. Abdominal radiographs showed decreased serosal detail with abdominal distension. Abdominal ultrasounds revealed gallbladder mucocele with generalized peritonitis showing stellate-like sludge in the gallbladder with echogenic fat degeneration of cranial abdomen and abdominal free fluid containing echogenic materials. Loss of gallbladder wall integrity was shown clearly on computed tomography but ambiguously on ultrasound. Ultrasound-guided abdominocentesis was performed and showed amount of yellowish-bloody peritoneal fluid with vegetable matter and mucoid substance. On peritoneal fluid analysis, bilirubin level was elevated over three times than those of the serum. On exploratory laparotomy, gallbladder rupture and generalized bile peritonitis with intestinal adhesions were confirmed and cholecystectomy with peritoneal lavage was performed. One day after operation, patient died. This report describes delayed clinical symptoms of gallbladder rupture by gallbladder mucocele. In addition, this is the first case report using computed tomography made a diagnosis gallbladder rupture in a dog. Computed tomography might be helpful to diagnose gallbladder rupture.

Current Status of Sewerage Technology Evalution Verification System and Direction for Improvement of the System (하수도 기술의 평가 인증제도 운영현황 및 방향)

  • Lee, Sang-Eun
    • 수도
    • /
    • v.24 no.5 s.86
    • /
    • pp.16-28
    • /
    • 1997
  • As sewerage works has become one of the major public works in Korea, the employment of advanced and more appropriate sewerage technology has become essential to improve the efficiency of sewerage works. During last 10 years, the Korean Government has made tremendous amount of investment on sewerage works so that treatment plants in 58 cities have treatment capacity which is equivalent to 52.8% of total daily sewage generation in Korea. This remarkable development, however, has heavily depended on one technology, the conventional activated sludge process as more than 95% of the existing plants employ this process, Recently, the Korean Government and local authorities have plans to introduce more appropriate sewage treatment technologies and research and development in this area has become very active. To encourage employing new and appropriate technologies, however, the proper technology evaluation and verification program for new process is needed. The public sector should play a key role in this program since the sewerage works is one of the major public works. In this paper, the technology evaluation and verification programs related with sewerage facilities in the US and Japan are briefly reviewed. The Innovatived and Alternative Technology programs which was operated by US EPA until recently and Environmental Technology Verification(ETV) program which was commenced in 1995 are introduced. The technology verification programs operated in Japan and also in Korea are also reviewed in this paper to propose a future direction for development of the appropriate evaluation and verification system.

  • PDF

Effects of the Redox Potential of the Acidogenic Reactor on the Performance of a Two-Stage Methanogenic Reactor

  • Phae, Chae-Gun;Lee, Wan-Kyu;Kim, Byung-Hong;Koh, Jong-Ho;Kim, Sang-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.1
    • /
    • pp.30-35
    • /
    • 1996
  • Distillery wastewater was used in a thermophilic laboratory-scale two stage anaerobic digester to test the effects of the redox potential of the first acidogenic reactor on the performance of the system. The digester consisted of first a acidogenic reactor and the an upflow anaerobic sludge blanket (UASB) reactor. The digestor was operated at a hydraulic retention time (HRT) of 48 h. Under these conditions, about 90% of the chemical oxygen demand as measured by the chromate method ($COD_{cr}$) was removed with a gas production yield of 0.4 l/g-COD removed. The redox potential of the acidogenic reactor was increased when the reactor was purged with nitrogen gas or agitation speed was increased. The increase in reduction potential was accompanied by an increase in acetate production and a decrease in butyrate formation. A similar trend was observed when a small amount of air was introduced into the acidogenic reactor. It is believed that the hydrogen partial pressure in the acidogenic reactor was decreased by the above mentioned treatments. The possible failure of anaerobic digestion processes due to over-loading could be avoided by the above mentioned treatments.

  • PDF

Electrolyte Addition for Enhanced Wastewater Treatment by Electrolysis using Cu Electrode

  • Kim, Woo-Yeol;Yun, Chan-Young;Son, Dong-Jin;Chang, Duk;Kim, Dae-Gun;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • In this study, the effect of electrolyte addition on the removal of organics and nutrients in electrochemical wastewater using a copper electrode, and the characteristics of the by-product of electrolysis were investigated. The removal of organics increased significantly as shorter reaction times upon the addition of chloride ion, and most of the electrolysis reaction was completed within 20 min. The reaction rate gradually increased in proportion to the $Cl^-$/COD ratio, whereas the highest removed mass of organic matter per mass of added electrolyte was observed at a $Cl^-$/COD ratio of 1. After the addition of electrolyte, significant removal of ammoniacal nitrogen was observed as a result of the enhanced generation of oxidizers such as hypochlorite. Excellent phosphorus removal was also achieved in a very short reaction time (within 2 min) by electro-coagulation. As the electrolysis progressed, the amount of by-product increased gradually, whereas a decrease of sludge volume index was observed after the addition of electrolyte. This indicated that the settling performance of the by-products was better, and their removal would be easily achieved.

Quantitative Evaluation of CO2 Sequestration in Ca-rich Waste Mineral for Accelerated Carbonation (가속탄산화를 통한 Ca-rich Waste Mineral의 정량적인 CO2 고용량 평가)

  • Nam, Seong-Young;Um, Nam-Il;Ahn, Ji-Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.2
    • /
    • pp.64-71
    • /
    • 2014
  • Accelerated carbonation is a technique that can be used as a CCS technology for $CO_2$ sequestration of approximately 5~20% in a stable solid through the precipitation of carbonate. An alkaline inorganic waste material such as ash, slag, and cement paste are generated from incinerators, accelerated carbonation offers the advantage of lower transport and processing costs at the same generation location of waste and $CO_2$. In this study, we evaluated an amount of $CO_2$ sequestration in various types of inorganic alkaline waste processed by means of accelerated carbonation. A quantitative evaluation of $CO_2$ real sequestration based on a TG/DTA analysis, the maximum 118.88 $g/kg_{-waste}$ of $CO_2$ in paper sludge fly ash, the maximum 134.46 $g/kg_{-waste}$ of $CO_2$ in municipal solid waste incinerator bottom ash, the maximum 9.72 $g/kg_{-waste}$ of $CO_2$ in industrial solid waste incinerator fly ash, and the maximum $18.19g/kg_{-waste}$ of $CO_2$ in waste cement paste.

Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration (고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구)

  • Kwon, Ki-Bum;Kim, Sang-Keun;Ramchanda, Prasad;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

Chemical Cleaning of Copper Corrosion Product Using EDTA.2Na Salt and Effect of Surface Treatment by NALCO-39L (EDTA.2Na를 이용한 구리 부식생성물의 화학세정 및 NALCO-39L에 의한 표면처리효과)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.86-92
    • /
    • 1999
  • This study was carried out to investigate the effect of chemical cleaning of corrosion product on cooling system made of copper as a basic material and using cooling water as pure water. We studied chemical cleaning condition that minimizes the influence on basic material by means of EDTA solution so as to eliminate the slurry in cooling system. In addition, the proper amount of NALCO-39L (Nitrite-Borate-BZT mixture) as a inhibitor was determined in order to protect the copper in cooling system against corrosion after chemical cleaning and the effect of corrosion resistance on the copper surface treated was excelent in comparison with surface untreated. As a result, we found that the main components of sludge in cooling system produced by corrosion of copper were $Cu_2O$, CuO, Cu, and Fe. The optimum condition of chemical cleaning was 400ppm EDTA solution at $60^{\circ}C$. Inhibitor concentration needed to treat the surface of pure copper was 15~20ppm per unit area and corrosion rate of copper treated with 500ppm inhibitor solution for 72 hrs at $60^{\circ}C$ was remarkably decreased as compared with that of pure copper.

  • PDF