• 제목/요약/키워드: Sludge Amount

검색결과 432건 처리시간 0.021초

습식 사이클론을 이용한 하수슬러지내 무기성분 및 MAP 분리 (Separation of Inorganic Sludge and MAP from Municipal Wastewater Sludge Using Hydrocyclone)

  • 이동우;배강형;조건상;김성홍
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.135-142
    • /
    • 2014
  • The performance of inorganic sludge separation system is evaluated. Anaerobic digester effluent sludge is used for feed sludge of this system and hydrocyclone is used for inorganic sludge separation. For phosphorus removal and recovery $MgCl_2$ is pumped into MAP growth tank, a component of inorganic sludge separation system. Using this system inorganic sludge which contained less than 40 % of organic matter can be discharged stably and the maximum amount of separated inorganic sludge is 13.4 % of influent sludge based on dry solid. The amount of phosphorus recovered as MAP(as P) is 16.7 % to influent T-P.

오수/합병정화조의 배출물 제어시스템 연구 (The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;김건호;오지영;임총규;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 추계학술대회
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구 (The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;박윤규;강경식
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

하수슬러지의 정제 연료화 기술(1) - 유기성 슬러지의 정제 고체연료 제조 - (Refined Fuel Production Using Municipal Sewage Sludge(I) - Preparation of Refined Solid Fuels from Organic Sludge -)

  • 강성규;이승재;유인수;이규철
    • 한국연소학회지
    • /
    • 제12권4호
    • /
    • pp.47-56
    • /
    • 2007
  • Utilization of sewage sludge for industrial fuel should be considered in appropriate calory with low emission of environmental pollutants and the amount of sewage sludge for continuously long-time operation. For the low grade fuel(<4,000kcal/kg), one of proper processes is that coal and oil are added into sewage sludge to remove impurities and increase calory(>7,000kcal/kg) and the amount of fuel having sewage sludge. Recently, 2-step agglomeration has been attempted by secondarily agglomerate sewage sludge onto the primary nuclei formed by agglomeration of coal and oil. Furthermore, sawdust and waste oil can substitute about 1/3 each for coal and mineral oil consumed in this process, which will lead to securing alternative energy resources from environmental pollutants as well as cost reduction.

  • PDF

활성슬러지를 이용한 납 이온 제거에 영향을 미치는 인자에 대한 연구 (A Study on the Factors Affecting Pb^{2+}$ Removal by Activated Sludge)

  • 김동석;김미경;서정호
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.559-564
    • /
    • 1998
  • The effects of temperature, initial $Pb^{2+}$concentration and initial sludge concentration on the initial $Pb^{2+}$ removal rate and maximal $Pb^{2+}$removal amounts in activated sludge, respectively, were investigated. The removal of $Pb^{2+}$ in activated sludge was proved to be temperature-dependent process. The initial $Pb^{2+}$ removal rate increased from 187.5 to 261.4 mg $Pb^{2+}$/g sludge dry weight min, in response to the promoted temperature from 1$0^{\circ}C$ to 6$0^{\circ}C$, while the maximal $Pb^{2+}$removal amount (78.5 mg $Pb^{2+}$/g sludge dry weight) occurred at 30t . As the initial $Pb^{2+}$concentration increased from 36 to 228 mg $Pb^{2+}$/L at the constant temperature of 30C and initial sludge concentration of 1.5 g sludge dry weight/L, the time to reach an equilibrium state was almost independent of the initial $Pb^{2+}$concentration and the equilibrium $Pb^{2+}$/removal amount was increased Irom 41.9 to 73.6 mg $Pb^{2+}$/g sludge dry weight. On the contrary, the equilbrium $Pb^{2+}$ emoval amount was decreased from 87.7 to 65.3 mg $Pb^{2+}$/g sludge dry weight as the in- crease of initial sludge concentration from 0.22 to 1.76 g sludge dry weight/L.

  • PDF

활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구 (Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank)

  • 손건태;김성덕;고주형
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

다양한 활성 슬러지 공정에서 얻은 잉여 슬러지의 마이크로웨이브 가온과 영양물질의 방출 (Release of Nutrients from Different Wasted Activated Sludges by Microwave Heating)

  • 양회원;안조환;김장호;김정환
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.701-708
    • /
    • 2018
  • Chemical batch tests were conducted to investigate the amount of nutrients that were released from the wasted activated sludge during microwave heating. For this study, three types of activated sludge were obtained from $A_2/O$, MLE and oxidation ditch (OD) processes. Polyphosphate-accumulating organisms in the activated sludge have a unique trait: they releases phosphate from the cell when they are exposed to high temperatures. The sludge obtained from the $A_2/O$ process released the largest amount of phosphate, followed by those from the MLE and OD processes. The release of phosphate increased with increasing polyphosphate content in the sludge under strongly alkaline or acidic conditions. Furthermore, ammonia and heavy metals were released with phosphorous. The largest amount of ammonia was observed from the sludge obtained from the MLE process. The release of heavy metals strongly depends on the pH conditions. Therefore, the chemical analysis results strongly suggest that both phosphorus and ammonia react with $Mg^{2+}$ or $Ca^{2+}$ to form metal complexes such as magnesium ammonium phosphate or hydroxyapatite under alkaline conditions.

유동층반응기에서 폐제지슬러지와 석회석의 탈황 동역학 (Desulfurization kinetics of waste paper-sludge and limestone in a fluidized bed reactor)

  • 조상원;오광중
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1089-1096
    • /
    • 2002
  • The objectives of this study were to investigate the desulfurization kinetics of paper sludge and limestone in a fluidized bed reactor according to bed temperature and air velocity. The experimental results were presented as follows ; First, the bed temperature had a great influence on the desulfurization efficiency of limestone and paper sludge. In paper sludge, the optimum condition in desulfurization temperature was at 80$0^{\circ}C$ and in limestone, that was at 850 $^{\circ}C$ or 900 $^{\circ}C$ Second, as air velocity increased, the desulfurization efficiency(or the absorbed amount of sulfur dioxide) by limestone and paper sludge decreased. And the absorbed amount of sulfur dioxide by paper sludge was larger than that of by limestone. Third, as the velocity increased and the optimum desulfurization temperature became, ks and the removal efficiency increased. So, ks, kd highly depended on the air velocity and bed temperature.

산 가수분해에 의한 폐활성슬러지 분해 (Disintegration of Waste Activated Sludge by Acid Hydrolysis)

  • 팟차리야 자이팍디;안영희
    • 생명과학회지
    • /
    • 제33권1호
    • /
    • pp.82-90
    • /
    • 2023
  • 하수와 산업폐수를 처리하는데 생물학적 공정이 전세계적으로 이용된다. 생물학적 공정은 복합미생물로 구성된 슬러지를 사용한다. 슬러지 미생물이 성장함에 따라 폐수처리공정에서는 잉여슬러지가 발생한다. 잉여슬러지의 일부는 미생물을 보충하기 위해 폐수처리공정에 반송되지만 나머지는 폐기물로서 처리된다. 매년 전세계적으로 폐수발생이 증가함에 따라 폐수처리장의 수도 증가하여 많은 양의 폐슬러지가 생산된다. 따라서 폐슬러지에 대한 관리와 처리가 중요하다. 폐슬러지 처리비용은 폐수처리장 총운영비의 50-60%를 차지한다고 보고되었다. 슬러지 분해기술은 폐슬러지의 부피를 최소화하고 유용한 성분(예, P, N, 용해성 유기물)을 회수할 수 있는 새로운 기술이다. 물리적, 화학적, 그리고 생물학적 처리 또는 복합 처리에 기반을 둔 다양한 슬러지분해방법들이 개발되었다. 본 총설은 슬러지 분해방법들 중에서 비교적 덜 연구된 산 가수분해에 의한 슬러지 분해에 대해 중점적으로 다루었다. 본 총설에서 다룬 정보는 폐슬러지 처리를 위한 더 나은 기술을 개발하고 이식하는데 유용하게 사용될 것이다.

활성황토 시멘트와 폴리실리콘 슬러지 치환율에 따른 경화체의 강도 특성 (Strength properties of matrix according replacment ratio by polysilicon sludge and active loess cement)

  • 강전욱;이원규;김대연;신진현;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.265-266
    • /
    • 2018
  • In recent years, active loess cement has been used instead of cement in order to reduce the amount of cement and industrial byproducts that are the main cause of environmental pollution. We also used polysilicon sludge as a by-product to reduce the amount of cement used and to improve the environmental pollution due to the reduction of carbon dioxide. Polysilicon is a raw material used in the production of panels for solar power generation. When producing 1 ton of polysilicon, 2 tons of sludge is generated. It is an experiment to reduce sludge treatment and cement usage. This study analyzed basic characteristics of polysilicon sludge and active loess cement according to replacment ratio.

  • PDF