• Title/Summary/Keyword: Slit3

Search Result 403, Processing Time 0.03 seconds

Optical Path Analysis for the Optical Encoder using Slit Internal Reflection (슬릿 내부 반사를 이용한 광학식 인코더의 광경로 해석)

  • Kweon, Yong-Min;Kweon, Hyun-Kyu;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.69-77
    • /
    • 2017
  • This paper introduces an optical encoder using the reflection in the slit. The digital optical encoder is a sensor to generate a pulse according to the displacement. An optical encoder is composed of 3 parts: light source, slit plate and light-receiving element. In a conventional encoder, one slit produces one signal. The resolution of the digital optical encoder is determined by the number of slits in the encoder plate. The small slit size is most important among the factors that determine the resolution in a generic-type optical encoder. However, a small slit has low productivity and technical difficulties, so analog optical encoders have emerged as an alternative. Nonetheless, this alternative requires additional circuitry and equipment because of the noise and drafts in the analog signals. A new sensor is presented in this paper with a high resolution and a slit of the same size using the reflection in the slit. Then, the path of the light that passes through the slit ccording to the shape was analyzed, and some paths were expressed in the mathematical expressions. In addition, the optical paths were analyzed in the rectangular, octagonal, and circular encoders, and shown the obtained number of signals per slit by using them. Thus, we confirm that this method has the best performance in circle-shaped slits.

The Reflection Characteristics of a Perforated Slit Caisson with Two Chambers (이중 유공슬릿 케이슨에 의한 반사특성)

  • Hur, Dong-Soo;Lee, Woo-Dong;Lee, Hyeon-Woo;Kim, In-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.60-67
    • /
    • 2010
  • Recently, there has been an increase in the construction of various types of coastal structures for efficient wave dissipation, seawater exchange, and so on. Among these, a perforated slit caisson has been widely used to reduce the reflected wave energy and the wave pressure on the structure. Therefore, many studies on the wave force on a caisson, as well as the wave reflection from it, have been carried out with laboratory experiments and numerical analyses, considering it as a 2-D problem. However, because a structure like a perforated slit caisson has a variable 3-D shape, waves forces should be considered as a 3-D problem. Therefore, in this paper, a fully-nonlinear 3-D numerical model (LES-WASS-3D) is proposed to examine the reflection characteristics of a perforated slit caisson with two chambers. The numerical model, LES-WASS-3D, was verified in a 3-D wave field by a comparison with existing experimental data for wave reflection coefficients. Then, using the numerical results, the reflection from a perforated slit caisson with two chambers was examined in relation to wave steepness, chamber width, and the shape/porosity of perforated slit.

Fast 3-dimensional profifle measurement using slit-ray projection method

  • Ishimatsu, T.;Kawasue, K.;Kumon, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.786-790
    • /
    • 1987
  • This paper describes a systein which enables a fast 3 -dimensional profile measurement using a slit-ray projection method. One distinctive feature of this system is that a real-time video is processor is employed in order to reduce the amount of image data to be processed without eliminating essential information. Experimental results show that a calibrating method presented for the TV camera and the slit-ray projector is convenient and enables sufficient accurate measurements.

  • PDF

Experimental evaluation of steel connections with horizontal slit dampers

  • Lor, Hossein Akbari;Izadinia, Mohsen;Memarzadeh, Parham
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.79-90
    • /
    • 2019
  • This study introduces new connections that connect the beam to the column with slit dampers. Plastic deformations and damages concentrate on slit dampers. The slit dampers prevent plastic damages of column, beam, welds and panel zone and act as fuses. The slit dampers were prepared with IPE profiles that had some holes in the webs. In this paper, two experimental specimens were made. In first specimen (SDC1), just one slit damper connected the beam to the column and one IPE profile with no holes connected the bottom flange of the beam to the column. The second specimen (SDC2) had two similar dampers which connected the top and bottom flange of the beam to the column. Cyclic loading was applied on Specimens. The cyclic displacements conditions continued until 0.06 radian rotation of connection. The experimental observations showed that the bending moment of specimen SDC2 increased until 0.04 story drift. In specimen SDC1, the bending moment decreases after 0.03 story drift. Test results indicate the high performance of the proposed connection. Based on the results, the specimen with two slit damper (SDC2) has higher seismic performance and dissipates more energy in loading process than specimen SDC1. Theoretical formulas were extended for the proposed connections. Numerical studies have been done by ABAQUS software. The theoretical and numerical results had good agreements with the experimental data. Based on the experimental and numerical investigations, the high ductility of connection is obtained from plastic damages of slit dampers. The most flexural moment of specimen SDC1 occurred at 3% story drift and this value was 1.4 times the plastic moment of the beam section. This parameter for SDC2 was 1.73 times the plastic moment of the beam section and occurred at 4% story drift. The dissipated energy ratio of SDC2 to SDC1 is equal to 1.51.

Defect Length Measurement using Underwater Camera and A Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.746-751
    • /
    • 2003
  • A method of measuring the length of defects on the wall of the spent nuclear fuel pool using the image processing and a laser slit beam is proposed. Since the defect monitoring camera is suspended by a crane and hinged to the crane hook, the camera viewing direction can not be adjusted to the orientation that is exactly perpendicular to the wall. Thus, the image taken by the camera, which is horizontally rotated along the axis of the camera supporting beam, is distorted and thus, the precise length can not be measured. In this paper, by using the LASER slit beam generator, the horizontally rotated angle of the camera is estimated. Once the angle is obtained, the distorted image can be easily reconstructed to the image normal to the wall. The estimation algorithm adopts a 3-dimensional coordinate transformation of the image plane where both the laser slit beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect taken at arbitrary rotated angle can be reconstructed to an image normal to the wall. From the result of a series of experiments, the accuracy of the defect is measured within 0.6 and 1.3 % error bound of real defect size in the air and underwater, respectively under 30 degree of the inclined angle of the laser slit beam generator. Also, the error increases as the inclined angle increases upto 60 degree. Over this angle, the defect length can not be measured since the defect image disappears. The proposed algorithm enables the accurate measurement of the defect length only by using a single camera and a laser slit beam.

  • PDF

Air-Side Performance of Fin-and-Tube Heat Exchangers Having Non-Symmetric Slit Fins Under Wet Condition (비대칭형 슬릿 핀이 적용된 핀-관 열교환기의 습표면 성능)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3698-3707
    • /
    • 2015
  • In this study, wet surface heat transfer and friction characteristics of non-symmetric slit-finned heat exchangers are experimentally investigated. Louver-finned heat exchangers are also tested for comparison purpose. The effect of fin pitch on j and f factor is negligible. Louver fin samples yield higher j and f factors than slit fin samples. For one row, j and f factors of louver fin are 27% and 31% higher than those of slit fin. For two row, j and f factors of louver fin are 15% and 30% higher. Both j and f factor decrease as the number of tube row increases. For one row, average j/f ratios of slit fin samples are 3.4% larger than those of louver fin samples. For two row, average j/f ratios of slit fin samples are 11.5% larger. A new correlation was developed using the present data.

Experimental study of performance characteristics of various fin types for fin-tube heat exchanger (휜-관 열교환기에 있어서 각종 휜 형상의 성능 특성에 관한 실험적 연구)

  • Yoon, Baek;Kim, Young-Saeng;Park, Hwan-Young;Park, Hyun-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.484-491
    • /
    • 1999
  • Air side heat transfer and pressure drop for ø9.52 fin-tube heat exchanger with various types of slit and louver fins were measured, and compared with wave-slit fin. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively. Actual heat exchanger was tested using water, and the tests were performed for 2 row heat exchangers with 3 different fin spacings, 1.3, 1.5 and 1.7mm. The overall performance of the enhanced fins was evaluated by comparing heat transfer coefficient with respect to fan power.

  • PDF

Experimental Study of Performance Characteristics of Various Fin Types for Fin-Tube Heat Exchanger

  • Youn, Baek;Kim, Young-Saeng;Park, Hwan-Young;Park, Hyun-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.29-38
    • /
    • 2000
  • Air side heat transfer and pressure drop for f 9.52 fin-tube heat exchanger with various types of slit and louver fins were measured, and compared with wave-slit fin. Longitudinal and transverse tube spacings of the heat exchangers are 21.65 mm and 25mm respectively. Actual heat exchanger was tested using water, and the tests were performed for 2 row heat exchangers with 3 different fin spacings, 1.3, 1.5 and 1.7 mm. The overall performance of the enhanced fins was evaluated by comparing heat transfer coefficient with respect to fan power

  • PDF

Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper (강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가)

  • Kim, Yu-Seong;Kang, Joo-Won;Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

Reflection and Hydraulic Characteristics inside Two-Chamber Vertical Slit Caisson in 3-D Oblique Wave Field (3차원 경사입사파동장에서 이중유공슬릿케이슨 내부의 수리특성 및 반사특성)

  • Hur, Dong-Soo;Lee, Jun;Lee, Woo-Dong
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • Using a 3-D numerical scheme (LES-WASS-3D) that considered wave-structure-sandy seabed interactions in a 3-D wave field, we analyzed the wave reflection and hydraulic characteristics inside a slit caisson with two chambers in a 3-D oblique wave field. To verify the 3-D numerical analysis method suggested in this study, we compared the numerical results with existing experimental results and found good agreement. The numerical analysis revealed that a standing wave field is generated on the front side of the slit caisson due to the effect of wave reflection. For incident waves propagating perpendicular to the slit caisson, the nodes and anti-nodes of the standing wave are apparent and symmetrical. However, in an oblique wave field, as the incident wave angle decreases, the nodes and anti-nodes of the standing wave become ambiguous and unsymmetrical. It was also found that the wave reflection coefficient decreases as the incident wave angle decreases. It can be pointed out that as the incident wave angle decreases, the turbulent intensity in the chamber increases. Thereby, the increased wave energy dissipation by the increased turbulent intensity reduces the rate of wave reflection. In addition, a strong turbulent intensity generally occurs in the first chamber.