• Title/Summary/Keyword: Slit

Search Result 1,008, Processing Time 0.032 seconds

A case of cataract surgery using phacoemulsification in a 12-year-old poodle

  • Kang, Myeong-Gon;Han, Dong-Hyun;Han, Sei-Myoung;Jung, Eun-Gyeom;Kim, Gyeong-Min;Cho, Jae-Hyeon;Koh, Phil-Ok;Won, Chung-Kil;Kim, Chung-Hui;Lee, Dongbin
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.3
    • /
    • pp.221-228
    • /
    • 2022
  • Cataracts occur commonly in older dogs, which can lead to partial or complete vision loss. In the present study, a 12-year-old male poodle presented for evaluation of ocular sinister (OS) cataract. This study was a clinical case report on the process of performing surgery using phacoemulsification (PHACO) and the problems that arise in patient diagnosed with OS cataract. In the oculus dexter (OD), the artificial eye was inserted because there was no electroretinography (ERG) response. In the OS, the ERG was 51.6 μV, so operation was performed because the visual pathway function remained. Slit-lamp biomicroscopy of the OS showed complete loss of vision as a hypermature cataract and that the lens was hardened. During the cataract surgery using PHACO, visco-elastic agents were used to maintain the shape of the eyeball, and the PHACO procedure took 3.13 minutes. The hardened lens and visco-elastic agents were removed from the eye through PHACO surgery, and the operation was completed by inserting an intraocular lens (IOL). As a result of managing IOP for 2 months after surgery, it remained stable at a maximum of 19 mmHg, and no postoperative ocular hypertension (POH) occurred. Currently, one year has passed since the operation, and the dog maintains its daily life with its left eye without any problems.

A Case of Choroidal Melanocytoma with Optic Nerve Involvement in a Dog

  • Jinseon Chang;Dajeong Jeong;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Clinics
    • /
    • v.40 no.4
    • /
    • pp.283-287
    • /
    • 2023
  • A 10-year-old spayed female beagle dog presented with a 2-month history of third-eyelid elevation in the left eye (OS). Ophthalmic examination revealed slightly diminished corneal and palpebral reflexes along with exophthalmos in the OS. Schirmer's tear test and intraocular pressure values were within the normal range for the OS. Slit-lamp biomicroscopy revealed protrusion of the third eyelid and corneal opacity in the OS. Fundoscopy revealed a prominent black mass in the OS covering the optic nerve. Tapetal hyper-reflectivity was also observed around the mass. Ocular ultrasonography showed a 0.74 × 0.67 cm echogenic posterior segment mass around the optic nerve protruding into the retrobulbar space. Computed tomography revealed a contrast-enhanced soft tissue lesion in the posteromedial aspect of the left eyeball protruding into the retrobulbar region, and the optic nerve was suspected to be involved. No evidence of osteolytic changes in the adjacent bone or distant metastasis was observed. Enucleation was performed to prevent potential metastasis or local invasion of the mass and to relieve discomfort due to exposure to keratopathy resulting from lagophthalmos. Histopathological examination revealed a central choroidal melanocytoma extending into the optic nerve. No local recurrence was detected until 16 months postoperatively.

Vapor phase synthesis of silicon nitride powder using DC plasma torch (DC 플라즈마 토치를 이용한 질화규소 분말의 기상합성)

  • Hwang, Y.;Sohn, Y.U.;Chung, H.S.;Choi, S.K.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.4
    • /
    • pp.370-377
    • /
    • 1994
  • DC plasma torch which is a non-transferred type was constructed and silicon nitride powders were produced. Ar gas is used as a plasma gas and gas reactants with the carrier gas are introduced beneath the plasma ignition part. Two slits are attached and a reactive quenching gas is introduced through them. Using $SiCl_4 and NH_3$ as starting materials, silicon nitride powders were produced. As-produced powders were amorphous and crystalline silicon nitrides were obtained by heating at $1420^{\circ}C$ for two hours under nitrogen atmosphere. Silicon nitride phase was identified in the XRD patterns and IR spectrum, and the image of the powders before and after heating was observed from the TEM analysis.

  • PDF

A Study on Consumer Consciousness and Purchasing Tendency on Pet Fashion Products(Dog Clothes) (펫패션 제품(반려견 옷)에 대한 소비자의식 및 구매성향에 관한 연구)

  • Myung-Hee Chung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.3
    • /
    • pp.31-39
    • /
    • 2023
  • This paper aimed to provide the basic data on consumers' awareness, behavioral patterns, and purchase methods for pet fashion(dog clothes). Research was conducted in April 2023 among 183 college students from universities in the Gyeonggi-do region. The analysis results are presented below. When asked if they think clothes are a daily necessity for dogs, 74.3% recognized clothes as a daily necessity for dogs. The biggest purpose of clothing for dogs was 'physical health (prevention of cold/heat, etc.)' with 60.1%. 96.7% of the respondents were very positive about the development prospects for the pet fashion industry. 46.4% of the subjects were currently living with a dog, and 30.6% of the subjects have lived with a dog for 'less than 1-3 years'. 93.0% of college students who live with a dog own dog clothes. As for the dog's clothing style, T-shirt styles without a slit were the most common at 33.6%. 81.0% of companion dog owners were found to dress their dogs when going out, and the most common reason was 'physical health (prevention of cold/heat, etc.)' at 76.6%. When purchasing dog clothes, 72.2% of the subjects considered 'fitting with the dog/convenience', and 27.8% were 'focusing on the companion's taste'. As for how to purchase dog clothes, 39.2% chose 'store visits and online purchases', 34.2% chose 'store visits and purchases', and 26.6% chose 'online purchases'. As for the most considered part when purchasing clothes for dogs, 51.9% identified 'design' and 39.2% identified 'material'. 80.7% of respondents said they would increase the purchase of dog clothes in the future.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Ultrasensitive Crack-based Mechanosensor Inspired by Spider's Sensory Organ (거미의 감각기관을 모사한 초민감 균열기반 진동압력센서)

  • Suyoun Oh;Tae-il Kim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Spiders detect even tiny vibrations through their vibrational sensory organs. Leveraging their exceptional vibration sensing abilities, they can detect vibrations caused by prey or predators to plan attacks or perceive threats, utilizing them for survival. This paper introduces a nanoscale crack-based sensor mimicking the spider's sensory organ. Inspired by the slit sensory organ used by spiders to detect vibrations, the sensor with the cracks detects vibrations and pressure with high sensitivity. By controlling the depth of these cracks, they developed a sensor capable of detecting external mechanical signals with remarkable sensitivity. This sensor achieves a gauge factor of 16,000 at 2% strain with an applied tensile stress of 10 N. With high signal-to-noise ratio, it accurately recognizes desired vibrations, as confirmed through various evaluations of external force and biological signals (speech pattern, heart rate, etc.). This underscores the potential of utilizing biomimetic technology for the development of new sensors and their application across diverse industrial fields.

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

Numerical Analysis of Unstable Combustion Flows in Normal Injection Supersonic Combustor with a Cavity (공동이 있는 수직 분사 초음속 연소기 내의 불안정 연소유동 해석)

  • Jeong-Yeol Choi;Vigor Yang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.91-93
    • /
    • 2003
  • A comprehensive numerical study is carried out to investigate for the understanding of the flow evolution and flame development in a supersonic combustor with normal injection of ncumally injecting hydrogen in airsupersonic flows. The formulation treats the complete conservation equations of mass, momentum, energy, and species concentration for a multi-component chemically reacting system. For the numerical simulation of supersonic combustion, multi-species Navier-Stokes equations and detailed chemistry of H2-Air is considered. It also accommodates a finite-rate chemical kinetics mechanism of hydrogen-air combustion GRI-Mech. 2.11[1], which consists of nine species and twenty-five reaction steps. Turbulence closure is achieved by means of a k-two-equation model (2). The governing equations are spatially discretized using a finite-volume approach, and temporally integrated by means of a second-order accurate implicit scheme (3-5).The supersonic combustor consists of a flat channel of 10 cm height and a fuel-injection slit of 0.1 cm width located at 10 cm downstream of the inlet. A cavity of 5 cm height and 20 cm width is installed at 15 cm downstream of the injection slit. A total of 936160 grids are used for the main-combustor flow passage, and 159161 grids for the cavity. The grids are clustered in the flow direction near the fuel injector and cavity, as well as in the vertical direction near the bottom wall. The no-slip and adiabatic conditions are assumed throughout the entire wall boundary. As a specific example, the inflow Mach number is assumed to be 3, and the temperature and pressure are 600 K and 0.1 MPa, respectively. Gaseous hydrogen at a temperature of 151.5 K is injected normal to the wall from a choked injector.A series of calculations were carried out by varying the fuel injection pressure from 0.5 to 1.5MPa. This amounts to changing the fuel mass flow rate or the overall equivalence ratio for different operating regimes. Figure 1 shows the instantaneous temperature fields in the supersonic combustor at four different conditions. The dark blue region represents the hot burned gases. At the fuel injection pressure of 0.5 MPa, the flame is stably anchored, but the flow field exhibits a high-amplitude oscillation. At the fuel injection pressure of 1.0 MPa, the Mach reflection occurs ahead of the injector. The interaction between the incoming air and the injection flow becomes much more complex, and the fuel/air mixing is strongly enhanced. The Mach reflection oscillates and results in a strong fluctuation in the combustor wall pressure. At the fuel injection pressure of 1.5MPa, the flow inside the combustor becomes nearly choked and the Mach reflection is displaced forward. The leading shock wave moves slowly toward the inlet, and eventually causes the combustor-upstart due to the thermal choking. The cavity appears to play a secondary role in driving the flow unsteadiness, in spite of its influence on the fuel/air mixing and flame evolution. Further investigation is necessary on this issue. The present study features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous works. In particular, the oscillatory flow characteristics are captured at a scale sufficient to identify the underlying physical mechanisms. Much of the flow unsteadiness is not related to the cavity, but rather to the intrinsic unsteadiness in the flowfield, as also shown experimentally by Ben-Yakar et al. [6], The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The work appears to be the first of its kind in the numerical study of combustion oscillations in a supersonic combustor, although a similar phenomenon was previously reported experimentally. A more comprehensive discussion will be given in the final paper presented at the colloquium.

  • PDF

Relationship of Glomerular Basement Membrane Alterations to Epithelial Cell Structure and Clinical Parameters in Alport Syndrome (Alport 증후군에서 사구체 기저막의 형태학적 변화와 사구체 상피세포의 구조 및 임상지표와의 관계)

  • Eom, Hye-Jin;Hong, Seung-Jin;Lee, Jae-Seung;Jeong, Hyeon-Joo;Kim, Young-Ki;Kim, Kee-Hyuck
    • Childhood Kidney Diseases
    • /
    • v.14 no.1
    • /
    • pp.22-31
    • /
    • 2010
  • Purpose : This study was performed to evaluate the relationship between glomerular basement membrane (GBM) alterations to epithelial cell (EpC) structure and renal function in Alport Syndrome (AS) patients. Methods : Fifteen patients diagnosed with AS (4-26yrs) were examined. The GBM in AS was categorized as : C1) normal, C2) minor alterations (widening of lamina rara interna or externa without lamina densa change), C3) nonspecific splitting of lamina densa, C4) basket-weaving pattern of lamina densa splitting. The length of each GBM portion along the epithelial side was measured on the systematically obtained electron microscopic photographs. Furthermore to obtain an objective assessment of the degree of glomerular EpC foot process change, the number of slit pores along $10\;{\mu}m$ of peripheral GBM in each category was obtained. Results : The percentage of normal GBM portion (C1) correlated inversely with daily protein excretion (g/day/$m^2$, P<0.05) and sum of the percentage of abnormal GBM portion (C2+C3+C4) had direct correlation with daily protein excretion (g/day/$m^2$, P<0.05). There were no significant relationships between the percentages of other categories of GBM alterations and creatinine clearance or protein excretion. There were no significant relationships between of creatinine clearance in relation to normal GBM(C1) portion as well as that in relation to sum of the percentage of abnormal GBM portion (C2+C3+C4). GBM abnormality did not correlate with age at biopsy. Conclusion : The extent of GBM structural abnormality is related to proteinuria in AS but the epithelial response is uniform even though the GBM ultrastructural lesions are not.