• Title/Summary/Keyword: Slip-In Tube

Search Result 86, Processing Time 0.019 seconds

Importance-Performance Analysis of Clinical Nutrition Management in Convalescent Hospitals in the Gyeongnam Area (경남지역 요양병원 임상영양관리에 대한 중요도와 실행도 분석)

  • Lee, Seon-Jeon;Park, Eunju
    • Journal of the Korean Dietetic Association
    • /
    • v.22 no.1
    • /
    • pp.53-69
    • /
    • 2016
  • The purpose of this study was to analyze the importance-performance of clinical nutrition management in convalescent hospitals. The research was carried out based on questionnaires administered from March to April, 2015 to 73 dietitians at 40 convalescent hospitals in the Gyeongnam area. There was a statistically significant difference between the mean scores for importance (4.01/5.00) and performance (2.95/5.00) of clinical nutrition management. The importance and performance grid analysis showed that participation in a nutritional management committee, administration of patients using a cooperation program among hospital departments, cooperation with a medical team on patient's nutrition status, nutrition initial assessment, nutrition care process for patients showing malnutrition, nutrition care process for tube feeding patients, management of a therapeutic diet, meal management using dietary slip instructions including a therapeutic diet, and explication of a therapeutic diet for patients scored high regarding importance and performance (doing great area). Medical records on patient's nutrition management, and nutrition counseling for requested patient scored low regarding the importance and high regarding performance (overdone area). Participation in medical rounds, personal nutrition education for patients, group nutrition education for patients, nutrition education for medical teams, development of a menu for therapeutic diet and standardized recipes, and provision of information on diet therapy for patients after discharge scored low regarding importance and performance (low priority area). Accreditation of convalescent hospitals and interest of medical professionals in clinical nutrition management were effective variables for the importance-performance gap of clinical nutrition management. In conclusion, the accreditation process and positive awareness of medical professionals with regard to clinical nutrition management had positive effects on reduction of the importance-performance gap in clinical nutrition management at convalescent hospitals. The strength of clinical nutrition management in the accreditation and development of an education program for increasing medical team or administrator interest in clinical nutrition management could lead to improvement of clinical nutrition management for elderly patients in convalescent hospitals.

A Study on Fretting-Wear Behavior of Inconel 690 due to Surrounding Temperature (주위 온도에 따른 Inconel690의 마멸 거동에 관한 연구)

  • 임민규;박동신;김대정;이영제
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.296-303
    • /
    • 2001
  • In nuclear power steam generators, high flow rates can induce vibration of the tubes resulting in fretting wear damage due to contacts between the tubes and their supports. In this paper the fretting wear tests and the sliding wear tests were performed using the steam generator tube materials of Inconel 690 against STS 304. Sliding tests with the pin-on-disk type tribometer were done under various applied loads and sliding speeds at air and water environment. Fretting tests were done under various vibrating amplitudes, applied normal loads and various temperatures. From the results of sliding and fretting wear tests, the wear of Inconel 690 can be predictable using the work rate model. Depending on normal loads and vibrating amplitudes, distinctively different wear mechanisms and often drastically different wear rates can occur. At room temperature, the wear coefficient K of Inconel 690 is 7.57${\times}$10$\^$13/Pa$\^$1/ in air and it is 1.93${\times}$10$\^$13/Pa$\^$1/ in water. At room temperature, it is found that the wear volume in air is more than in water. In water, the wear coefficient K at 50$^{\circ}C$ and 80$^{\circ}C$ is 4.35${\times}$10$\^$-13/Pa$^1$ and 5.81${\times}$10$\^$-13/Pa$^1$ respectively, Therefore, it is found that the wear volume extremely increases by increasing on temperature in water. This study shows that the dissolved oxygen with temperature increment increases and the wear due to fluidity is severe.

  • PDF

Experimental Study of Steam Reforming Assisted by Catalytic Combustion in Concentric Annular Reactor (촉매연소를 이용한 동심 원관형 반응기 내의 수증기 개질 반응에 관한 실험적 연구)

  • Ghang, Tae-Gyu;Yu, Sang-Seok;Kim, Yong-Mo;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.375-381
    • /
    • 2010
  • In this paper, the heat-transfer characteristics of steam reforming in an annular reactor are presented. Heat is supplied by the catalytic combustion of syn-gas. The thermal behaviors of exothermic and endothermic reactions in a directly coupled concentric-tube packed-bed reactor were investigated experimentally. The gas mixture supplied for catalytic combustion consisted of the off-gas emitted from MCFC anode. Methane in steam at a suitable S/C (steam-to-carbon) ratio was used in the reforming reactions. On the basis of the experimental results, a simple simulation was performed to predict the temperature profile required in the reforming side of the reactor to achieve optimum hydrogen yield. The results of this study may be utilized as reference data in future studies for further development of coupled reactors.

Analytical Study of Net Section Fracture in Special Concentrically Braced Frames (중심가새골조의 순단면 파단에 관한 해석적 연구)

  • Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • Failure modes result in fracture or tearing, which may cause deterioration of resistance and reduction of inelastic deformation capacity. The potential failure modes for Special Concentrically Braced Frames (SCBFs) include fracture or tearing of the brace, net section fracture of the brace or gusset plate, fracture of the gusset plate welds, shear fracture of the bolts, block shear, excessive bolt bearing deformation, and buckling of the gusset plate. HSS tubular braces are commonly used in SCBFs, and net section fracture of the tubular brace may also occur through the brace net section at the end of the slot cut into the tube to slip over the gusset plate. This failure mode is categorized as a tension failure mode, and may cause dramatic loss of resistance and brittle behavior. Net section reinforcement is required according to AISC design specifications (AISC 2001). In this paper, the need to reinforce the net section area was discussed. Initially, the results of the net section fracture tests done by the University of California in Berkeley were presented with the modeling of these tests using FE models. To investigate the possibility of net section fracture in an actual frame, the slot end hole model was adapted to the frame FE model, and alternate near-fault histories were applied with tension-dominated cycles, since previous analyses showed that loading history was the most critical factor in net section fracture. The need for this reinforcement (cover plate) and the tension-dominated near-fault history were investigated.

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

Oxidation of Organic Compounds Using $TiO_2$ Photocatalytic Membrane Reactors ($TiO_2$ 광촉매 막반응기를 이용한 유기물의 산화)

  • 현상훈;심세진;정연규
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.152-162
    • /
    • 1994
  • The photodegradation efficiency of formic acid on $TiO_2$ photocatalytic membranes was investigated. A new titania membrane reactors for purification of water combining microfiltration with photocatalytic degradation of organic compounds were developed. Titania membrane tubes(average pore size of $0.2\mu m$) were prepared by the slip casting, and porous thin films of $TiO_2$ were formed on the tube surface by the sol-gel process to increase the surface area, and consequently to increase photodegradation efficiency of organic compounds. The UV light with the wavelength of 365 nm was used as a light source for photocatalytic reactions. The photodegradation efficiency of the organic compounds was strongly dependent on the flux of the solution, the microstructure of the membrane (sol pH), and the amount of $O_2$ supplied. The effects of the primary oxidant such as $H_2O_2$ and dopants such as $Nb_2O_5$ on the photodegradation efficiency were also investigated. The results showed that more than 80% of formic acid could be degraded using membrane coated with a $TiO_2$ sol of pH 1.45. The photodegradation efficiency could be improved by about 20% when adding $H_2O_2$ in feed solution or doping $TiO_2$ membranes with $Fe_2O_3$.

  • PDF