• 제목/요약/키워드: Slice scan order

검색결과 7건 처리시간 0.026초

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming (Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System)

  • 김판기;임종우;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.95-102
    • /
    • 2007
  • 목적: 3.0 Tesla와 같은 고 자장에서 고해상도의 나선주사영상을 얻기 위해서는 주자장을 균일하게 만들어야 한다. 특히, 나선주사영상인 경우 스핀-에코펄스 시퀀스(SE)나 경사자계 에코 펄스 시퀀스(GE)에 비하여 측정 시간이 길기 때문에 주자장이 균일하지 못하다면, off-resonance 현상으로 영상의 blur가 심해진다. 본 연구에서는 빠른 시간 안에 주자장을 균일하게 할 수 있는 고차(Higher-order) shimming방법을 모색했다. 대상 및 방법: 3 Tesla 자기 공명 영상시스템에서 고해상도의 나선주사영상을 얻기에 적합할 정도의 균일한 주자장을 빠른 시간 안에 만들기 위해, 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구할 수 있는 펄스 시퀀스를 제안하였고, 불균일도 map으로부터 spherical harmonics 분석를 통해 shim 코일에 적절한 전류를 인가하여 주자장을 균일하게 만들었다. 결과: 3 Tesla 자기 공명 영상 시스템에서 주자장의 불균일도는 주자장의 크기에 비례하게 된다. 제안한 펄스 시퀀스로 얻은 영상을 이용하여 불균일도 Map을 만들 수 있었고, 이를 spherical harmonics 분석을 하여 2-3회의 고차 shimming으로 불균일한 자장을 균일하게 만들 수 있었다. 제안된 고차 shimming 방법은 전체 영상 영역 뿐만 아니라 선택한 영역에 대해서만 적용도 가능하기 때문에 국부 영역에 대한 고차 shimming이 가능하다. 고차 shimming이 적용되어 주자장이 균일하게 개선된 상태에서 고해상도의 나선주사영상을 얻을 수 있었다. 결론: 3 Tesla 고자장 자기 공명 영상 시스템에서 주자장의 불균일도를 개선하기 위한 펄스 시퀀스와 알고리즘을 통해 주자장의 불균일도를 빠른 시간 안에 개선할 수 있었다. 주자장의 불균일도를 효과적으로 개선함으로써, 고해상도의 나선주사 영상을 얻을 수 있었다.

  • PDF

동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구 (Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order)

  • 변재후;박명환;강지연;이진완;이강원;장건호
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.108-118
    • /
    • 2013
  • 동맥스핀표지(Arterial Spin Labeling: ASL) 뇌 관류 자기공명영상법을 이용한 뇌 관류영상기술이 일반적으로 환자의 질병진단에 일반적으로 사용하기 어려운 이유는 영상을 얻을 때 여러 인자들을 최적화시켜야만 좋은 질의 영상을 얻을 수 있기 때문으로 생각된다. 따라서, 본 논문의 목적은 동맥스핀표지 자기공명영상의 뇌 관류영상을 최적화 하기 위하여 필요한 여러 인자들의 변화에 따른 동맥스핀표지 신호변화를 3.0 테슬라 자기공명영상에서 관찰하는 것이다. 특히, 동맥시 핀표지 자기공명영상 신호 변화가 이들 인자에서 뇌 세포(brain tissues)의 영역에 따라서 어떻게 변화하는가를 평가하였다. 정상 성인 남성 5명을(평균연령 36세; 29세~41세) 대상에서 STAR (Signal Targeting with Alternating Radiofrequency) 동맥스핀표지 방법을 이용하여 3T 자기공명영상에서 영상을 얻었다. 실험은 첫째 영상획득 영역과 라벨링 영역간의 간격 변화에 따른 신호 변화 평가 실험, 둘째 라벨링 후의 시간 변화에 따른 신호 변화 평가 실험, 셋째 라벨링 두께의 변화에 따른 신호 변화 평가 실험, 넷째 슬라이스 획득 순서에 따른 신호 변화 평가실험을 하였다. 획득한 영상의 분석은 회백질과 백질, 전두엽, 측두엽, 후두엽, 두정엽에서의 관류신호변화를 얻어 분석하였다. 본 연구결과는 아래와 같았다: 1) 영상획득 영역과 라벨링 영역간의 간격 변화에 따른 관류 신호 변화 연구결과 전체 절편의 평균 값을 보면 회백질에서 좌측과 우측 모두에서 라벨링 간격이 증가할수록 신호가 낮아지는 경향을 보이고 있다. 라벨링 간격의 변화에 두정엽이 가장 영향을 적게 받고 후두엽이 가장 많은 영향을 받았다. 2) 라벨링 후의 시간 변화에 따른 관류 신호 변화 연구결과 회백질은 라벨링 지연시간 400 ms까지 양쪽 모두 감소하다가 라벨링 지연시간이 1,000 ms까지 증가하였다. 3) 라벨링 두께의 변화에 따른 관류 신호 변화 연구 결과 라벨링 두께가 증가에 따라 회백질과 백질의 신호강도는 점차적으로 증가하다가 120 mm 두께 이후에는 감소하였다. 4) 절편 획득 순서에 따른 관류 신호 변화 연구 결과 절편 획득 순서에 따른 백질과 회백질의 관류신호강도 값은 회백질과 백질 모두 머리의 꼭대기부터 영상을 획득하는 descend에서 신호강도가 높았다. 본 연구에서는 각 실험 조건에 따라서 관류신호 강도가 크게 변화를 하는 것을 보여 주었고, 따라서 실제 환자를 대상으로 관류 영상을 얻고자 할 경우에는 실제 임상 적용 전에 최적화된 프로토콜을 만든 후에 사용을 해야 할 것으로 생각한다. 특히 백질의 뇌 관류영상을 얻는 것은 아직 문제가 있는 것으로 생각이 된다.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발 (Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology)

  • 김정완;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

뇌기능 자기공명영상 장치를 이용한 짠맛 자극에 따른 인간 뇌의 반응에 대한 기초 연구 (Salty-taste Activation of Human Brain Disclosed by Gustatory fMRI Study)

  • 김수현;최기승;이현용;신운재;은충기;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제9권1호
    • /
    • pp.30-35
    • /
    • 2005
  • 목적 : 본 논문은 뇌 기능 자기공명영상(Brain Functional Magnetic Resonance Imaging: Brain fMRI)을 이용하여 짠 맛 자극에 대한 인지활동으로 뇌 신경세포의 활성화에 따른 국소 대사 및 혈류역학적 변화가 일어나는 뇌 영역을 분석 및 가시화함으로써 맛에 대한 뇌 활성화 부위의 기초자료를 마련하고자 하였다. 대상 및 방법 : 건강한 비흡연 남자 12명을 대상으로 1.5T MRI 장치에서 혈액산소수준의존(Blood Oxygen Level Dependent, 이하 BOLD) 방법을 이용한 fMRI 실험을 수행하여 인간의 미각 중 짠맛에 대한 반응을 관찰하였다. 잔 맛의 자극은 $3\%$ 농도의 소금물(NaCl)을 미각 자극기를 이용하여 혀 전체에 자극을 주었다. 미각 자극기인 Auto Syringe Pump는 일정한 자극을 반복적으로 가할 수 있도록 마이크로프로세서를 이용하여 연구실에서 자체 제작되었다. 자극의 패러다임은 5회의 휴식기간과 4회의 자극기간으로 구성되었으며, 자극기간은 15초씩 진행되고 휴식기간은 30초로 하여 각 slice당 42 영상을 연속적으로 획득하였다. 자극에 대해 얻은 fMRI 영상은 SPM99'(Statistical Parametric Mapping, UCL)를 이용하여 분석하였다. 활성화 영상은 EPI 영상과 동일한 부위의 T1 강조영상에 registration 기법을 이용하여 overlapping시켜 활성화 부위의 해부학적 판별을 용이하도록 하였다. 결과 : 농도 $3\%$ 소금물의 짠맛 자극에 대해서 insula, amygdala, frontal opercular taste cortex (OFC), orbitofrontal cortex 영역에서 활성화 영역을 fMRI로 확인하였으며, dorsolateral prefrontal cortex (DLPFC) 영역에서도 유효한 신호를 관찰하였다. 결론 : 본 연구의 결과는 미각의 주요 신경이 뇌의 insula, OFC 그리고 DLPFC 영역에 주로 분포한다는 기존의 결과와 잘 일치하고 있다. 마이크로 프로세서로 동작하는 자동펌프를 미각 자극기로 사용함으로써 미각자극에 대한 뇌의 활성화 영역을 안정되게 관찰할 수 있었다. 본 연구의 결과는 fMRI를 이용한 고차원적 미각작용 과정 연구에 튼튼한 밑거름이 될 것으로 생각된다.

  • PDF