• 제목/요약/키워드: Slice ion imaging

검색결과 3건 처리시간 0.041초

Photodissociation of Nitrous Oxide by Slice Ion Imaging: The Stagnation Pressure Dependence

  • Cheong, Nu-Ri;Park, Hye-Sun;Nam, Sang-Hwan;Shin, Seung-Keun;Cho, Soo-Gyeong;Lee, Hai-Whang;Song, Jae-Kyu;Park, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2661-2664
    • /
    • 2009
  • Photodissociation of nitrous oxide near 203 nm has been studied by a combination of high resolution slice ion imaging technique and (2+1) resonance-enhanced multiphoton ionization (REMPI) spectroscopy of $N_2(X^1{{\Sigma}_g}^+)$ via the (a″$^1{{\Sigma}_g}^+$) state. We have measured the recoil velocity and angular distributions of $N_2$ fragments by ion images of the state-resolved photofragments. The $N_2$ fragments were highly rotationally excited and the NN-O bond dissociation energy was determined to be 3.635 eV. Also, we investigated the photofragment images from the photodissociation of $N_2O$ clusters with various stagnation pressures.

토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교 (Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy)

  • 이병구;강수만
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.145-149
    • /
    • 2013
  • 의료용 선형가속기 (linear accelerator)와 나선형 컴퓨터 단층 촬영 장치 (helical computed tomography scanner)의 결합 장치인 토모테라피는 세기 변조 방사선 치료 (intensity modulated radiation therapy(IMRT))의 큰 혁신을 이끌었다. 토모테라피 치료 과정에서, Megavoltage computed tomography (MVCT) 영상획득은 치료 환자의 정확한 자세 정렬을 위해 치료 전 또는 후에 이용된다. 그러나 이는 환자의 총 선량을 증가시키는 결과를 만들며, 본 연구는 이처럼 MVCT 영상 획득 시 증가되는 선량을 Cylindrical "Cheese" Phantom을 이용하여 측정, 비교하였다. 각각의 pitch 별로 (1, 2, 3 mm) 동일한 개수의 slice (10 slice), 그리고 동일한 length (약 9 cm)를 scanning하여, 이때의 선량 (MVCT Scanning Dose)을 A1SL ion chamber를 이용하여 측정하였다. 측정 결과 동일한 Slice 개수 (각각의 pitch 당 10개)일 때, MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.24 cGy, 1.02 cGy, 0.81 cGy가 측정되었다. 동일한 length에서 MVCT scanning dose의 평균값은 각각 (pitch 1, 2, 3mm) 2.47 cGy, 1.28 cGy, 0.88 cGy가 측정되었다. 이는 할당된 pitch와 scanning length가 MVCT scanning dose에 큰 영향을 미치는 가장 중요한 매개 변수임을 말하며, pitch는 MVCT scanning dose와 역비례 관계를 나타냈다. 때문에 적절한 pitch와 scanning length의 선택으로 치료 선량 외의 추가 선량을 최소로 줄여야 하겠다.

SIMS Protein imaging with nanoparticle tagged antibody for simultaneous omic imaging

  • 이선영;문대원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.230.1-230.1
    • /
    • 2015
  • One of the major problems of biological ToF-SIMS imaging is the lack of protein and peptide imaging. Most of biological story telling is mianly based on proteins. The biological implication of lipid ToF-SIMS imaging would be much higher if protein imaging is provided together. Utilizing high secondary ion yields of metals, proteins can be ToF-SIMS imaged with nanoparticle tagged proteins. Nanoparticles such as Fe3O4, SiO2, PbS were used for imaing NeuN, MCH, Orexin A, ${\alpha}$ synucline, TH(Tryosine Hydroxylase) in mouse tissues with a spatial resolution of ${\sim}2{\mu}m$ using a TOF-SIMS. Lipids and neurotransmitters images obtained simultaneously with protein images were overlayed for more deeper understanding of neurobiology, which is not allowed by any other bioimaging technqiues. The protein images from TOF-SIMS were compared with confocal fluorescence microscopy and NanoSIMS images. A new sample preparation method for imaging single cell membranes in a tissue using the vibrotome technique to prepare a tissue slice without any fixation and freeze drying will be also presented briefly for Hippocampus and Hypothalamus tissues.

  • PDF