• Title/Summary/Keyword: Slice interval

Search Result 33, Processing Time 0.031 seconds

Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography (초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구)

  • Lee, Jong-Seok;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.149-160
    • /
    • 2007
  • Recent advent of 64-multidetctor (MD) CT enables more coverage of Z-axis in the perfusion imaging. The purpose of this study was to evaluate the clinical usefulness of perfusion CT by using 64-MD CT in detecting the lesion in patients with acute stroke. The perfusion CT was performed by using 64-MD CT in 62 consecutive patients who were initially suspected to have subacute ischemic stroke symptoms during the period of recent 9 months. These patients had subacute stroke (n=62). CT scanning was conducted with Jog Mode which provided 16 imaging slices with 5 mm of slice thickness, and 8 cm of coverage in Z-axis. Scan interval was 1 seconds for each imaging slice and total 15 scans were repeated. After CT scanning, perfusion maps (CBV, CBF, MTT and TTP) were created at Extended Brilliance Workstation. The CBV and CBF maps showed that lesions were smaller images. While on the MTT and TTP map lesions were seen to be larger fifty-one were large than they appeared on these images. Two slices of perfusion maps obtained at the level of the basal ganglia were chosen to simulate conventional older perfusion CT with 8 cm of coverage in Z-axis. TTP and MTT maps may be clinically useful for evaluation of the penumbral zone in cases of aubacute cerebral ischemic stroke. The perfusion CT is useful in the assessment of acute stroke as an initial imaging modality.

  • PDF

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

A Study on The Time For Movement of Myosin Heads by the Twitch Stimulation (Twitch Stimulation에 의한 Myosin Heads 움직임의 시간분석 연구)

  • Kim, Duck-Sool;Jung, Jung-Su;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.182-189
    • /
    • 2004
  • On contraction of the muscles, marked changes in X-ray reflections are observed, suggesting that conformational changes of contractile molecules and the movement of myosin heads during muscle contraction. Time slice requires tension peak after the onset of stimulation and the height of tension peak depends on the number of twitch cycle. The muscles were stimulated by five successive stimuli at an interval of 80 ms started while the tension was still being exerted by the muscles. The intensity of $I_{11}$, $I_{10}$, $143{\AA}$ and $215{\AA}$ reflection measured with 5ms time resolution and is recorded in isometric tension. The peak height of $I_{11}$ and $143{\AA}$ intensity is changed after the onset of a stimulation $I_i$, and the length of twitch is shortened by successive twitches in the case of stimulation $T_i$. On the other hand, the peak height of In and $215{\AA}$ intensity starts to decrease at the 1st twitch and remains constant at low peak height without appreciable recovery during the contraction term. In the case of successive twitch stimulation, the myosin heads of muscle are once moved from their resting position and never returned to their initial position.

An Estimation on Area Error For Surface Roughness Advancement of Rapid Prototype by FDM (FDM에서 단면오차법을 이용한 표면예측)

  • 전재억;김수광;황양오;박후명;하만경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1869-1872
    • /
    • 2003
  • As SLA(Sterealithography), SLS(Selective Laser Sintering), LOM(Laminated Object Manufacturing), FDM(Fused Deposition Modeling) etc. The FDM system the heart of a study and is developed by Stratasys co. ltd, in US., is small and cheap R.P. The material filament is heated until the material reaches a near-liquid state, it is pumped through a nozzle and become hand with a shape required, and this nozzle move pumping on the previously deposited material. Such FDM system that choice deposition type with X-Y plouter obtain in the thin continue layer by decreasing amount of extrusion or to central the injection amount when the head slow down at the corner, but in the process that fusion wax or resin become hand, deformation occur and it will affect the shape accuracy and the surface roughness. Such effect will depreciate quality and reliability of the product. Therefore, when the product made in actuality, the fundamental study on the basis geometry(surface, volume, line, angle) must be preceded and it have been research by many Free Form Fabrication. So, this basic object study purpose to obtain the fundamental geometry data and to enhance the surface roughness of the shape. And an operant can use the data for the progress of the surface roughness. This study research the estimation and application of the prototype surface roughness by adjustment the injection amount. And basie of this research, describe the pattern of prototype surface roughness and also used the result to estimate the surface of prototype.

  • PDF

Dynamic voltage scaling policy for processors with fast voltage transition on personal computing environment (이동형 개인 컴퓨팅 환경의 에너지 효율 증가를 위한 빠른 전압 조절을 고려한 가변 성능 알고리즘)

  • Seo, Eui-Seong;Lee, Joon-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.763-765
    • /
    • 2005
  • DVS(dynamic voltage sealing)은 이동형 프로세서에서 에너지 효율을 높이기 위한 필수 요소로 자리 잡고있다. DVS를 효과적으로 사용하기 위해선 대상 태스크의 특성과 하드웨어 특성에 맞는 DVS 알고리즘이 필요하다. 상품화 수준의 않은 운영체계들이 일정한 인터벌(interval)을 바탕으로 시스템 사용 상황을 분석하여 목표 성능을 결정하는 방식을 사용하고 있다. 이러한 방식은 태스크의 특성이 갑자기 변하여 성능을 요구할 경우 인터벌만큼의 시간이 진행된 후에야 반응 한다는 단점이 있다. 또한, 태스크 별 특성이 아닌 시스템 전체의 특성을 따르므로 이질적인 성격의 태스크들이 동시에 실행 되는 환경에는 적합하지 않다. 최근의 모바일 프로세서들은 수 마이크로초 수준의 성능 전환 시간을 제공하고 있으며 이 속도는 계속 줄어들고 있다. 프로세서의 고성능화로 인해 I/O 작업의 경우 프로세서 성능에 따른 실행 시간의 차이가 존재 하지 않는다. 이러한 두 가지 특성을 바탕으로 우리는 TIB(timer interrupt based) 알고리즘을 제안한다. TIB 알고리즘은 일정한 길이의 인터벌 대신 타임 슬라이스(time slice)를 성능 결정의 단위로 삼는다. 성능의 결정은 태스크 별로 이루어지며 각 태스크가 사용했던 이전 타임 슬라이스가 타이머 인터룹트(timer interrupt)에 의해 끝났다면 최대의 성능을 그 외의 경우는 최저의 성능으로 실행하게 된다. 이러한 접근 방식을 통해 I/O 작업이나 이벤트를 기다리는 태스크에 대해 최저 성능을 제공함으로써 실행 시간의 적은 손해를 대가로 많은 에너지 절감을 이룰 수 있다. 또한, 태스크의 속성이 변한 경우 타임 슬라이스 길이 만큼의 지체만을 허용하게 된다. 이러한 TIB 인터벌에 기반한 알고리즘에 비해 개별 태스크의 특성에 따른 성능 조절과 태스크의 변화에 따른 빠른 반응을 자랑으로 한다. 본 논문에선 TIB 알고리즘을 리눅스 커널에 구현하여 성능을 평가하였고 그 결과 리눅스에서 사용되는 기존 인터벌 기반의 알고리즘들에 비해 좋은 전력 절감 효과를 얻을 수 있었다.

  • PDF

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI (FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle)

  • Han, Jae-Bok;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.101-106
    • /
    • 2009
  • Purpose of this study is to compare the signal intensity (SI) and CNR with T1 weighted image using FLASH at 3T abdominal MRI by varying flip angle (FA). Totally 20 patients (male : 12, female : 8, Age : $28{\sim}63$ years with mean : 51) were examined by 3 Tesla MR scanner (Magnetom Tim Trio, SIEMENS, Germany) with 8 channel body array coil between september and October 2008. Imaging parameters were as follows : FLASH sequence, TR : 120 ms, TE : minimum, FOV (field of view) : $360{\times}300\;mm$, Matrix : $256{\times}224$, slice : 6 mm, scan time : 15 sec and Breath-hold technique. Abdominal image, with a 50 ml syringe filled with water placed in the FOV measuring the water signal, were acquired with varying FA through $10^{\circ}$ to $90^{\circ}$ with $10^{\circ}$ interval. SI's were measured three times at liver parenchyme, water, spleen and background and averaged. The CNR's were measured between the ROIs (region of interest). Statistic analysis was performed with ANOVA test using SPSS software (version 17.0). Less than FA $30^{\circ}$, abdominal images were severely inhomogeneity. Especially, T1 effect of water signal was weak. As the flip angle increased, the signal intensity decreased at all the regions. Especially, flip angle of the highest signal intensity was observed with $40^{\circ}$ at the liver parenchyme, $20^{\circ}$ at water, $30^{\circ}$ at the spleen, respectively. The CNR between liver and water was -60.92 at FA $10^{\circ}$ and 15.16 at FA $80^{\circ}$. The CNR between liver and spleen was -3.18 at FA $10^{\circ}$ and 9.65 at $80^{\circ}$. In conclusion, FA $80^{\circ}$ is optimal for T1 weighted effect using FLASH pulse sequence at 3.0 T abdominal MRI.

  • PDF

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing (방사성의약품 검사 시 진단(CT)영상에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Seul;Kim, Gha-Jung;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF