• Title/Summary/Keyword: Sleep Measurement

Search Result 145, Processing Time 0.028 seconds

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Rest-Activity Rhythm and Sleep pattern in the Elderly (노인의 휴식.활동 일주기 생체리듬과 수면양상)

  • Kim, Myung-Ye;Lee, Eun-Ju
    • Journal of Korean Biological Nursing Science
    • /
    • v.13 no.3
    • /
    • pp.211-219
    • /
    • 2011
  • Purpose: The study compared the rest-activity rhythm and sleep pattern of elderly with young group. Methods: The subjects were 22 over than 65 years old and 23 under 65 years old. An actigraph, sleep diary, Pittsburgh Sleep Quality Index and Insomnia Severity Index scale were used as measurement tools for this study. The data were analyzed with $x^2$, Lamda test, t-test and correlation with SPSS 15.0 program. Results: The elderly had lower curve than the young group in rest-activity rhythm on each time zone. In particular, the elderly group had lower rest-activity rhythm curve of 8, 9, 14, 18, 19, 20, 21, 22 and 23 time zone than those of young group. Sleep pattern had statistical difference in the total sleep time, PSQI and insomnia. Total sleep time of elderly had lower score and PSQI and Insomnia had higher score than young group. Age had correlation with rest-activity rhythm, sleep efficiency, PSQI and insomnia. Conclusion: Rest-activity rhythm of the elderly showed an increase in activity in the early morning because of earlier get up than the young group and an decrease in activity in the afternoon because of taking a nap at this time. Elderly sleep was that total sleep time increased but sleep efficiency decreased and insomnia intensified. This sleep pattern was related to age and rest-activity rhythm.

The Effects of Quality of Life and Occupational Performance on Quality of Sleep in College Students

  • Kim, Deokju
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.47-56
    • /
    • 2022
  • The purpose of this study is investigate the effects of quality of life and occupational performance on quality of sleep in college students. Data had been collected from Sep. 1 to Sep. 30, 2021. The subjects of this study were students majoring in occupational therapy at C College situated in C region. For analysis, 103 copies of questionnaire were used. As study instruments, a structured questionnaire incorporating questions about general characteristics, and measurement scales for quality of life, quality of sleep, and occupational performance evaluation were applied. Subjective sleep quality and sleep latency of study participants had lower scores than other components. According to the analysis on different quality of sleep depending on general characteristics, women had more sleep disturbances as they didn't have any part-time job. In terms of the correlation between quality of sleep and quality of life, physical health and total score (quality of life) had correlations with daytime dysfunction. With regard to influential factors on quality of sleep, rest & sleep as a domain of occupational performance and work affected quality of sleep. Students' quality of sleep will be improved if they keep regular habits of living, have rest appropriately for alleviating their stress, and do their jobs with interest and successfully according to a procedure. It is expected that the results of this study will be helpful to care for the health of would-be experts in charge of national health care.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Nintendo Wii Fit-Based Sleepiness Testing is Not Impaired by Contagious Sleepiness

  • Tietavainen, Aino;Kuvaldina, Maria;Haeggstrom, Edward
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.236-238
    • /
    • 2018
  • Sleep deprivation may cause accidents, and it has deteriorating effects on health. A measurement of postural steadiness by a portable and affordable Nintendo Wii Fit balance board can be used to quantify a person's alertness. At work, people are under the influence of their environment-often other peopl-dthat may affect their alertness. This work investigates whether sleep deprivation among people is "contagious," as quantified by sway measures. We measured 21 volunteers' postural steadiness while alert and sleep deprived. During the measurements, a screen placed in front of the participants showed a footage of either alert or sleep-deprived faces. We found a significant difference between the day time and night time steadiness, but found no effect resulting from watching footage of sleep-deprived people. This finding shows that a posturographic sleepiness tester quantifies physiological sleep deprivation, and is insensitive to the influence of social factors.

Factors Influencing Sleep Patterns during Clinical Practice Weeks among Nursing Students : Based on Spielman's Model (임상실습기간 중 간호대학생의 수면 영향요인: Spielman의 수면장애모델을 근간으로)

  • Kim, Mi Ye;Choi, Hee Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.203-212
    • /
    • 2016
  • Purpose: The purpose of this study was to identify the sleep patterns of nursing students using self-report questionnaire and physiologic measurement, to examine the factors influencing sleep patterns in based on Spielman's model. Methods: Participants were 119 nursing students who were in the clinical practice period. Self-report questionnaires and actigraphy were used to collect the data. Data were analyzed using descriptive statistics, correlation and regression by the SPSS/WIN 21.0 programs. Results: When sleep was measured by self-report questionnaire, 84 students (70.6%) showed poor sleep quality. The mean sleep efficiency was 82.6%, and 67 students(56.3%) showed low sleep efficiency (less than 85.0%). The factors affecting subjective sleep pattern measured by KMLSEQ were circadian sleep type (${\beta}=.28$, ${\rho}=.003$) and alcohol (${\beta}=.20$, ${\rho}=.031$). The factors affecting total sleep time were sedentary behavior (${\beta}=-.27$, ${\rho}=.003$) and daytime sleepiness (${\beta}=-.33$, ${\rho}$<.001). Conclusion: Many nursing students in their clinical practice period expressed sleep disturbance. Factors affecting the perceived sleep measured by the self-report questionnaire and objective sleep evaluated by physiologic measures were different. The evening type of students perceived poor sleep quality, however, sedentary life style and daytime sleepiness resulted in short sleep time. Therefore, more studies measuring the objective sleep characteristics are needed using subjective and objective characteristics.

Sleep Assessment During Shift Work in Korean Firefighters: A Cross-Sectional Study

  • Jeong, Kyoung Sook;Ahn, Yeon-Soon;Jang, Tae-Won;Lim, Gayoung;Kim, Hyung Doo;Cho, Seung-Woo;Sim, Chang-Sun
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.254-259
    • /
    • 2019
  • Background: This cross-sectional study assessed the sleep quality using the ActiGraph and investigated the relationship between the parameters of sleep assessment and the type of shift work in Korean firefighters. Methods: The participants were 359 firefighters: 65 day workers (control group) and 294 shift workers (shift work group: 77 firefighters with 3-day shift, 72 firefighters with 6-day shift, 65 firefighters with 9-day shift, and 80 firefighters with 21-day shift). Sleep assessments were performed using the ActiGraph (wGT3X-BT) for 24 hours during day shift (control and shift work group) and night shift and rest day (shift work group). The participants recorded bed time and sleep hours during the measurement period. Results: Sleep efficiency, total sleep time, and percentage of wake after sleep onset during night work were lower in the shift work group than control group (p < 0.05). Sleep efficiency decreased in night shift and increased in rest day, whereas wake after sleep onset increased in night shift and decreased in rest day (p < 0.05). Among shift work groups, sleep efficiency of 6-day shift was higher in day shift, and sleep efficiency of 21-day shift was lower in night shift than other shift groups (p < 0.05). Conclusion: We found that the sleep quality in night shift of the shift work group was poorer than the control group. As to the type of shift work, sleep quality was good in 6-day shift and poor in 21-day shift. Thus, fast rotating shift such as 6-day shift may be recommended to improve the sleep quality of the firefighters.

Measurement of Apnea Using a Polyvinylidene Fluoride Sensor Inserted in the Pillow (베게에 삽입된 PVDF센서를 이용한 무호흡증 측정)

  • Keum, dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.407-413
    • /
    • 2018
  • Most sleep apnea patients exhibit severe snoring, and long-lasting sleep apnea may cause insomnia, hypertension, cardiovascular diseases, stroke, and other diseases. Although polysomnography is the typical sleep diagnostic method to accurately diagnose sleep apnea by measuring a variety of bio-signals that occur during sleep, it is inconvenient as the patient has to sleep with attached electrodes at the hospital for the diagnosis. In this study, a diagnostic pillow is designed to measure respiration, heart rate, and snoring during sleep, using only one polyvinylidene fluoride (PVDF) sensor. A PVDF sensor with piezoelectric properties was inserted into a specially made instrument to extract accurate signals regardless of the posture during sleep. Wavelet analysis was used to identify the extractability and frequency domain signals of respiration, heart rate, and snoring from the signals generated by the PVDF sensor. In particular, to separate the respiratory signal in the 0.2~0.5 Hz frequency region, wavelet analysis was performed after removing 1~2 Hz frequency components. In addition, signals for respiration, heart rate, and snoring were separated from the PVDF sensor signal through a Butterworth filter and median filter based on the information obtained from the wavelet analysis. Moreover, the possibility of measuring sleep apnea from these separated signals was confirmed. To verify the usefulness of this study, data obtained during sleeping was used.

Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device (휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발)

  • Gyoung-Hahn Kim;Seong-Woo Woo;Sung Hun Ha;Jinlong Piao;MD Sahin Sarker;Baejeong Park;Chang-Sei Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

Rest-Activity Rhythm, Sleep Pattern and Quality of Life in Patients with Restless Legs Syndrome (하지불안증후군 환자의 휴식.활동 리듬, 수면 양상 및 삶의 질에 대한 연구)

  • Lee, Eun-Ju
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.3
    • /
    • pp.422-432
    • /
    • 2009
  • Purpose: In this study rest-activity rhythm, sleep pattern and quality of life of patients with restless legs syndrome were compared with those of a normal group. Methods: The participants in this study were 36 patients with restless legs syndrome diagnosed by a neurologist and 36 participants in the normal group. An actigraph, sleep diary, Pittsburgh Sleep Quality Index and Insomnia Severity Index scale were used as measurement tools for the study. Chi-square test, Lamda test, t-test and Kendall's correlation with SPSS 12.0 program were used to analyze the data. Results: Patients with restless legs syndrome had a higher rest-activity rhythm curve of Least 5 hr's activity(L5) and Most 10 hr's activity(M10) than those of normal group and sleep problems included decreased sleep efficiency and increased sleep latency, wake time and number of awakenings. The scores for the subscales of quality of life in patients with restless legs syndrome were lower than the normal group for general health, physical functioning, role limitations due to emotional problems, role limitation due to physical problems, social functioning, bodily pain, vitality and mental health. Conclusion: The results suggest that further studies are needed to identify rest-activity rhythm according to symptom severity and to develop nursing interventions which consider rest-activity rhythm.