• Title/Summary/Keyword: Slate roofing

Search Result 16, Processing Time 0.027 seconds

Asbestos Concentrations in Ambient Air and Drained Rainwater from Slate Roofing by Construction Year and Roof Area (슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도)

  • Jang, Bong-Ki;Ryu, Je-Young;Tak, Hyun-Wook;Song, Su-Jin;Lee, Jong-Wha;Lee, Gang-Ho;Choi, Jae-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.196-204
    • /
    • 2013
  • Objectives: The purpose of this study is to analyze the number and influence factors of asbestos fibers in the air of farmhouses with asbestos cement slate roofing, as well as in rainwater per unit area of the asbestos cement slate roofing. Methods: At a distance of 1 m from the end of asbestos cement slate roofing in 20 farmhouses, the asbestos fiber in the air was collected three times on a clear day downwind from the prevailing wind. Rainwater falling from the slate roofing was collected four times with a 1.05-m rainwater pipe on a rainy day at the 20 farmhouses, filtered with a MCE filter, and analyzed with a phase contrast microscope. Results: The geometric mean of the number of asbestos fibers in the air of farmhouses with slate roofing was 0.11 fiber/L, and no samples exceeded the recommended standard of 10 fiber/L. As a result of multiple regression analysis, a factor which gave a significant influence to the asbestos fiber content in the air was the gross area of slate roofing at the target farmhouses. The number of asbestos fibers included in rainwater collected per 1 m2 of slate roofing was 1,753 fiber/$L{\cdot}m2$. As a result of multiple regression analysis, the number of asbestos fibers contained in rainwater per 1 m2 of slate showed a significantly higher tendency as the year of slate roofing installation at the target farmhouses receded. Conclusions: It was confirmed for the first time in Korea that asbestos from asbestos cement slate roofing scatters into the air.

The Types of the Rural Housing in the Sea Islands of Gyeongnam with Special Reference to the Roofing Types and Materials (경남 도서지역 촌락의 가옥 유형에 관한 연구 - 지붕 형태와 지붕 재료를 중심으로 -)

  • Lee, Jeon;Seong, Hwa Ryong
    • Journal of the Korean association of regional geographers
    • /
    • v.21 no.4
    • /
    • pp.660-672
    • /
    • 2015
  • The rural housing is a key element of the rural landscape. The studies on the rural housing have focused on folk housing, but this study focuses on the comtemporary rural housing. The research area is the eight rural settlements on the sea islands of Gyeongnam. This study may provide the base for an understanding Korean rural landscape through the analysis of the rural housing types with special reference to the roofing types and materials. Most roofing types but the flat roofing type belong to the traditional roofing types. Among the combined-style roofing(결합양식지붕) types, the pitched-and-flat roofing(경사-평지붕) type is about ten times more frequent than the pitched-and-pitched roofing(경사-경사지붕) type. The most frequent roofing materials are cement, precoated steel plate(컬러강판), and artificial slate(인조슬레이트). Five typical types of rural housing are derived from the remarkable combinations of roofing types and roofing materials in the research area.

  • PDF

Releasing of asbestos fibers from the weathered asbestos cement slate roofing (슬레이트 지붕 노후화에 따른 석면 섬유 방출량)

  • Kim, Hyun-Wook;Park, Gye-Young;Han, Jin-Gu;Han, Young-Sun;Hwang, Bum-Gu;Lee, Jun-Hyuk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.88-93
    • /
    • 2010
  • To confirm and quantify asbestos fibers released from the asbestos-cement slate roofs due to weathering, three houses, selected based on the year of built - 60's, 70, and 80's, were investigated. All of them were located in the downtown of Seoul. Rain or snow-melt water was collected from the roof in a 3.5 liter plastic bottle. A known amount of collected water was filtered on the 37 mm membrane filter, ashed in a muffle furnace, and subsequently treated with HCl to remove organic material. The treated remaining was refiltered on a 25mm membrane filter for PLM and PCM analyses. The NIOSH 7400 method was utilized for PCM counting. In addition, SEM/EDX was used to confirm the asbestos types. The results of this study showed that chrysotile fibers were confirmed by PLM in all samples analyzed. A significant amount of asbestos fibers were found in the water samples. The ranges of asbestos fibers counted from the samples collected in the 60's, 70's, and 80's were; 10,406.3~55,575.6 f/L, 5,218.8~38,126.2 f/L, and 2,906.3~7,798.6 f/L, respectively. As anticipated, concentrations of asbestos fibers increased with time of installment of the roofing material. We conclude that weathering can be a significant factor on the release of asbestos fibers from the asbestos cement products. Since asbestos fibers released into environment can be a source of significant health hazard, countermeasures, such as replacement, removal, and encapsulation of weathered asbestos slate, should be initiated immediately.

The Effect of Roofing Materials for Using Harvested Rainwater (집수빗물이용을 위한 지붕면 재질의 영향)

  • Lee, Ju Young;Kim, Tschung-Il;Kim, Hyunwoo;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.623-629
    • /
    • 2012
  • The objective was to evaluate the quality of harvested rainwater of the roofing materials used and the presence of lichens/mosses on the roofing surface. This experiment was studied in the field where five pilot structures with different roofing materials (i.e., wooden shingle tiles, wooden shingle tiles (including mosses), concrete tiles, clay tiles [Gi-Wa] and slate tiles) were installed. As a result, the clay tiles [Gi-Wa] was found to be the most suitable for rainwater harvesting applications. It was due to the disinfection from ultraviolet light and high temperature according to characteristic of roofing materials. Comparison with quality of rainwater on that wooden shingle tiles with and without including mosses, which may affect the concentration of and wooden shingle tiles including mosses, mosses may affect concentration of TOC, nitrate, and sulfate. Additionally, the average concentration of asbestos was determined to be measured at $0.002/cm^3$ for the slate tiles. The value satisfied with it met the Ministry of Environment's Multi-use facility standard and Ministry of Labor's Office standard ($0.01/cm^3$).

Health Risk Assessment and Evaluation of Asbestos Release from Asbestos-cement Slate Roofing Buildings in Busan (부산시내 석면슬레이트지붕 건축물로부터의 석면 노출 및 건강위해성 평가)

  • Jeong, Jae-Won;Cho, Sunja;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1579-1587
    • /
    • 2013
  • This study was performed to evaluate the asbestos exposure levels and to calculate excess lifetime cancer risk (ELCR) for the risk assessment of the asbestos fibers released from asbestos-cement slate roofing (ASR) building. Total number of ASR buildings was into 21,267 in Busan, and 82.03 percent of the buildings was residential houses, and 43.61 percent of the buildings was constructed in 1970s. For this study, ten buildings were selected randomly among the ASR buildings. The range of airborne asbestos concentration in the selected ten ASR buildings was from 0.0016 to 0.0067 f/mL, and the concentration around no-admitted ASR buildings was higher than that around admitted buildings. The ELCR based on US EPA IRIS (integrated risk information system) model is within 3.5E-05 ~ 1.5E-04 levels, and the ELCR of no-admitted ASR buildings was higher than 1.0E-04 (one person per million) level that is considered a more aggressive approach to mitigate risk. These results indicate that the cancer risk from ASR buildings is higher than other buildings, and systematic public management is required for control of no-admitted ASR buildings within near future.

A study on repairing construction of Registered Cultural Properties of Jollanamdo -In consideration of material and patterns by repairing project- (전라남도 등록문화재의 수리공사에 관한 조사 연구 -수리공사에 따른 재료 및 형태 변화를 중심으로-)

  • Shin, Woong-Ju;Gill, Jong-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • This study is a research examining reshaped pattern in the perspective of repairing parts and materials through repairing renovation of registered cultural properties constructed in modern times and results are as followings. Repairing construction of registered cultural properties of Jollanamdo according to parts is shown numerously in the order of roof, walls and windows, and mostly outworn as time passes on and leakage were the main cause of repair. Also when original shape was damaged by previous repair in the past, and this was another reason of repairing. It was surveyed that among the repairing job repair of damage occurred on the part of roofing area including water leakage, corrosion and damage of roofing material, and damage of groove channel were the most main cause of repair. Especially when roof leakage is occurred by outworn of roofing materials, this cause corrosion and damage of materials due to the damage of leakage parts and this cause repeating cycles of worse leakage again and again. Main repairing materials which deform the original shape of registered cultural properties were confirmed as copper plate used on the roof. Copper plate showing high frequency of application which replaces groove slate or cement roofing tile used on the roof before has high durability and anti-corrosion but it is considered improper material to recover original shape.

A Study on Types and Contents of Asbestos in Bulk Samples (국내 석면 고형시료 중 석면의 종류 및 함유량에 관한 연구)

  • Choi, Ho-Chun;Ahn, Sun-Hee;Hong, Jwa-Ryung;Jeon, Bong-Hwan;Lee, Young-Pil;Park, Chung-Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.201-208
    • /
    • 2011
  • Objectives: According to the compliance of the asbestos-related regulation, every building has to be inspected for asbestos presence before its abatement work. This study was performed for identifying the types and contents of asbestos in building bulk samples. Materials and Methods: Bulk samples were collected during the asbestos inspection in 2010. We grouped the bulk samples into the regulated asbestos containing materials(RACM), presumed asbestos containing materials(PACM), and construction products. Additionally, the types of asbestos in all bulk samples were identified by polarization microscopy(PLM). Results: The RACMs were from building, house, pipe and facility. The RACMs were found mainly building (72.1%) and house (93.7%). The contents of chrysotile in building, house and facility were 66.9% (1-90%), 89.7% (2-90%) and 11.0% (2-90%), respectively. PACMs were surfacing material, thermal system insulation (TSI), and miscellaneous material. The miscellaneous materials that showed a high detection rate (79.2%) were ceiling, roofing and wall materials. Among them, the roofing materials had high chrysotile content(9.7%, 2-21%), followed by wall (8.7%, 2-21%) and ceiling (3.4%, 1-17%). In the construction products, asbestos was found mainly in slate (92.6%, 2-21%), including chrysotile. The slate had high asbestos content (9.7%, 2-21%), followed by cement flat board (8.7%, 2-19%) and textile (3.4%, 1-17%) Conclusions: Utilizing these results, it would be contributed to construct a useful ACM database and prevent from asbestos exposure to workers in the asbestos abatement and maintenance works.

A Basic Study on the Evaluation Factor for Deteriorated Level of Rural House (농촌주택의 노후도 평가요소 도출을 위한 기초연구)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.107-108
    • /
    • 2014
  • The rural area has aged and depressed for urban area in Korea. Furthermore, the rural house has deteriorated and is vulnerable to disaster which collapse, fire, landslide, and so on. For this matter, it need to an evaluated system for deteriorated level of rural house. The evaluated system has a repairing method and an estimated cost for rural house to offer native in rural area. This study could draw evaluation factor for deteriorated level of rural house as a basic study for the evaluated system. The evaluation factors is compared the Korean housing performance grade indication system, the Korean green building certification criteria, and the Japanese housing performance indication system. As a result, they could eight types. There are a mothproof, an waterproof, a finishing material, an asbestos cement slate of roofing, a mobility right, an opening and closing of doors and windows, an indoor environment.

  • PDF

The Types and Characteristics of Rural Housing in Ulleungdo Mountains (울릉도 산지 촌락 가옥의 유형과 특성)

  • Lee, Jeon
    • Journal of the Korean Geographical Society
    • /
    • v.51 no.3
    • /
    • pp.441-454
    • /
    • 2016
  • This study deals with the contemporary rural housing with special reference to the roof types/materials and the outer wall materials in Ulleungdo Mountains. The most frequent roof type of rural housing is the hip-and-gable roof type(42.1%); and the next, the gable roof type(25.8%). For the roof materials, the precoated steel plate(69.1%), the asphalt shingle(11.8%), and the cement(10.7%) are the most frequent but the roofing tile and the artificial slate are not used. And for the outer wall materials, the cement(27.5%), the siding(21.3%), the corrugated galvanized iron(16.8%), and the lumber sheet(6.7%) are the most frequent. It is the hip-and-gable roof housing type with the precoated steel plate(roof materials)(41%), or the hip-and-gable roof housing type with the precoated steel plate(roof materials) and the cement(outer wall material) (18.0%) that is the most frequent type of rural housing in Ulleungdo Mountains. For the roof/wall materials, the ratio of the corrugated galvanized iron is high probably due to the relatively low cost of transport, and the ratio of the roofing tile, the artificial slate, the red brick, and the building stone is very low probably due to the relatively high cost of transport.

  • PDF