• Title/Summary/Keyword: Slab Wick Heat Pipe

Search Result 3, Processing Time 0.014 seconds

An Experimental Study of a Slab Wick Heat Pipe for Medium-high Operating Temperatures (중온 작동 범위에서의 슬랩윅 히트파이프 성능에 관한 실험 연구)

  • Chung, Won-Bok;Boo, Joon-Hong;Kwak, Hee-Youl
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1630-1637
    • /
    • 2002
  • A slab-wick heat pipe was fabricated and tested for applications where the condenser temperature is in a range of 80 to 12$0^{\circ}C$. The pipe material was 9.53 mm O.D. copper tube and the working fluids were ethanol and water. The total length of the heat pipe was 1.6 m, in which evaporator section was 1.4 m and the condenser was 0.10 m. The slab was a composite wick structure fabricated with STS316 wire screens. Thermal load was varied for a specified fill charge ratio and inclined angle. The optimum fill charge ratio was identified to be 110% based on a theoretical calculation of the pore space in the slab wick of the heat pipe. The maximum thermal load was 120W for ethanol and the same was 200W for water with the condenser temperature of 8$0^{\circ}C$. The thermal performance of the slab wick heat pipe is analysed in terms of temperature characteristics and thermal resistance against thermal load, tilt angle and fill charge ratio.

A Comparative Study of Heat Pipes with Enlarged Condenser Section for Evacuated Solar Collectors (확관 응축부를 갖는 진공관형 태양열 집열기용 히트파이프 성능 비교 연구)

  • Boo, Joon-Hong;Chung, Won-Bok;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.18-25
    • /
    • 2002
  • For application to medium temperature solar collerctors $(80\sim120^{\circ}C)$, a heat pipe should be designed properly to efficiently transfer heat to a hotter condenser than common applications. Among many wick structure candidates for heat pipes of this type, a slab wick was selected based on promising performance data reported previously. The thermal performance of slab wick heat pipes, screen wick heat pipes and thermosyphons with enlarged condenser section were experimentally investigated for comparison purpose. The heat pipes were 8.0 mm O.D. (evaporator section) and 25.4 mm O.D. (condenser section) made of copper. The experimental data of the heat pipes were analysed in terms of thermal resistance against thermal load and coolant temperature.

A study on the improvement of the heat pipe performance with non metallic circumferential wick (非金屬 環狀윅을 갖는 히이트파이프 性能개선에 관한 연구)

  • 서정일;장영석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.713-723
    • /
    • 1986
  • The purpose of this research was to study the heat transfer characteristics of heat pipe which used non-metallic(SiO$_{2}$), circumferential wick and meshed slab wick as ADI method and experimental results. Compared wick experimental data and results by ADI method showed the good agreement and ADI method was utilized in pridicting the performance of heat pipe. Also, ADI method was applied to predict heat pipe performance according to the various volume ratios of metallic bond. The heat transfer characteristics of heat pipe could be predicted by heat flux and superheat term below the maximum heat flux limit. According to the addition ratio of metallic bond, heat transfer ratio could be improved as 2-3 times and when heat conductivity ratio(K$_{b}$/K$_{a}$) was increased at 4-12 ratio, heat transfer was in creased as 1.7-2.4 times, and the prediction of heat transfer could be show as exponential type. In producting non-metallic wick used to low heat pipe, metallic bond which is the conductivity of good quality and enduring for high temperature will be improved as in important problem.