• Title/Summary/Keyword: Skull

Search Result 868, Processing Time 0.03 seconds

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging (3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안)

  • Chang, Hye-Sook;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.313-325
    • /
    • 2002
  • Three-dimensional CT imaging is efficient in examining specific structures in the craniofacial area by reproducing actual measurements through minimization of errors from patient movement and image magnification. Due to the rapid development of digital image technology and the expansion of treatment range a need for developing three -dimensional analysis has become urgent. Therefore the purpose of this study was to evaluate the percentage of error and magnification of three-dimensional CT using a dried skull and Vworks $program^{TM}$ (Cybermed Inc., Seoul, Korea) and also to obtain landmarks that are easy to designate and reproduce in three-dimensional images using the Vmorph-proto $program^{TM}$ (Cybermed Inc., Seoul, Korea). The following conclusions were obtained, 1. In the comparison of actual measurements from the dried skull and the three-dimensional image obtained from the Vworks program, the mean error was 0.99mm and the magnification was 1.04%. 2. Clinically useful hard tissue landmarks from three-dimensional images were Supraorbitale, Lateral orbital margin, Infraorbitale, Nasion, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch and Basion. 3. Clinically useful soft tissue landmarks from three-dimensional images were Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton and Preaurale. The Vworks program can be considered a clinically efficient tool to produce and measure three-dimensional images. Most of the hard and soft tissue landmarks proposed above are anatomically important points which are also easily reproducible and designated. These landmarks can be beneficial in three-dimensional diagnosis and the prediction of changes before and after surgery.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.

Evaluation of the Neural Fiber Tractography Associated with Aging in the Normal Corpus Callosum Using the Diffusion Tensor Imaging (DTI) (확산텐서영상(Diffusion Tensor Imaging)을 이용한 정상 뇌량에서의 연령대별 신경섬유로의 변화)

  • Im, In-Chul;Goo, Eun-Hoe;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.189-194
    • /
    • 2011
  • This study used magnetic resonance diffusion tensor imaging (DTI) to quantitatively analyze the neural fiber tractography according to the age of normal corpus callosum and to evaluate of usefulness. The research was intended for the applicants of 60 persons that was in a good state of health with not brain or other disease. The test parameters were TR: 6650 ms, TE: 66 ms, FA: $90^{\circ}$, NEX: 2, thickness: 2 mm, no gap, FOV: 220 mm, b-value: $800s/mm^2$, sense factor: 2, acquisition matrix size: $2{\times}2{\times}2mm^3$, and the test time was 3 minutes 46 seconds. The evaluation method was constructed the color-cored FA map include to the skull vertex from the skull base in scan range. We set up the five ROI of corpus callosum of genu, anterior-mid body, posterior-mid body, isthmus, and splenium, tracking, respectively, and to quantitatively measured the length of neural fiber. As a result, the length of neural fiber, for the corpus callosum of genu was 20's: $61.8{\pm}6.8$, 30's: $63.9{\pm}3.8$, 40's: $65.5{\pm}6.4$, 50's: $57.8{\pm}6.0$, 60's: $58.9{\pm}4.5$, more than 70's: $54.1{\pm}8.1mm$, for the anterior-mid body was 20's: $54.8{\pm}8.8$, 30's: $58.5{\pm}7.9$, 40's: $54.8{\pm}7.8$, 50's: $56.1{\pm}10.2$, 60's: $48.5{\pm}6.2$, more than 70's: $48.6{\pm}8.3mm$, for the posterior-mid body was 20's: $72.7{\pm}9.1$, 30's: $61.6{\pm}9.1$, 40's: $60.9{\pm}10.5$, 50's: $61.4{\pm}11.7$, 60's: $54.9{\pm}10.0$, more than 70's: $53.1{\pm}10.5mm$, for the isthmus was 20's: $71.5{\pm}17.4$, 30's: $74.1{\pm}14.9$, 40's: $73.6{\pm}14.2$, 50's: $66.3{\pm}12.9$, 60's: $56.5{\pm}11.2$, more than 70's: $56.8{\pm}11.3mm$, and for the splenium was 20's: $82.6{\pm}6.8$, 30's: $86.9{\pm}6.4$, 40's: $83.1{\pm}7.1$, 50's: $81.5{\pm}7.4$, 60's: $78.6{\pm}6.0$, more than 70's: $80.55{\pm}8.6mm$. The length of neural fiber for normal corpus callosum were statistically significant in the genu(P=0.001), posterior-mid body(P=0.009), and istumus(P=0.012) of corpus callosum. In order of age, the length of neural fiber increased from 30s to 40s, as one grows older tended to decrease. For this reason, the nerve cells of brain could be confirmed through the neural fiber tractography to progress actively in middle age.

The fate of spargana inoculated into the cat brain and sequential chan'germ of anti-sparganum IgG antibody levels in the cerebrospinal fluid (고양이 뇌에 주입된 스파르가눔의 운명과 숙주 뇌척수액 IgG 항체가의 경시적 변화)

  • Wang, Kyu-Chang;Huh, Sun;Hong, Sung-Tae;Chai, Jong-Yil;Choi, Kil-Soo;Lee, Soon-Hyung
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 1990
  • To establish an animal model of intracranial sparganosis, the fate and behavior of the experimentally inoculated spargana were observed. A total of 102 scolices of spargana were injected into 22 cat brains, and the cats were sacrificed at 2 weeks, 1 month, 3 months and 6 months after the inoculation. Neurosparganosis was established in 77% of the cats. Of 43 recovered worms,19 (44%) were located in the subdural or subarachnoid space,16 (37%) in the brain Parenchyme, and 2 (5%) in the lateral ventricle. One was detected at the diploic space of the skull and 5 were outside the cranial cavity. All but one were alive, and had grown tails. They were distributed in the brain parenchyme randomly. There was no place which they could not invade. No adult was found in the intestine. Cerebrospinal fluid (CSF) was collected before inoculation, 1 week, 2 weeks, 1 month, 3 months and 6 months after inoculation. The level of anti-sparganum IgG antibody in CSF measured by ELISA began to increase above the criteria of positivity 1 month after inoculation. Three months after inocula- tion, the values markedly increased. The present findings reveal that intracranial inoculation of spargana into the brains of cats would be a good animal model of experimental neurosparganosis.

  • PDF

A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM (산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구)

  • Park Eung Chun;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

A STUDY OF HOLOGRAPHIC INTERFEROMETRY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO THE MAXILLARY PROTRACTION USING THE ANTENNA TYPE MODIFIED PROTRACTION HEAD GEAR (Modified Protraction Headgear를 이용한 상악골 전방 견인시 악안면골의 초기반응에 관한 Holographic Interferometry 연구)

  • Lee, Kong-Geun;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.531-556
    • /
    • 1992
  • The majority of the commonly used protraction headgears for the protraction of small and/or retropositioned maxilla not allow a change in the point of force application or direction of the force delivery to attain predictable results because of the position of the upper and lower lips to avoid discomfort to the patient. The purpose of this study was to investigate the initial reaction of maxillofacial complex according to the change of force variables such as direction and point of force application with designing an antenna type-modified protraction head gear. A macerated human skull with well aligned upper teeth was used to experimental model and the investigation was done by double exposure holographic interferometry. Fringe patterns of each protraction conditions were compared and analized. The results were as follows. (Frontal view) 1. The Counterclockwise rotation of the maxilla was showed by parallel protraction to occlusal plane and the fringe was decreased in number as higher point of force application. 2. Generally, the number of fringe was increased in 500gm of protraction force than in 300gm. 3. When apply the protraction force to the maxilla with rapid palatal expansion, the direction of fringe patterns was differed from the protraction without expansion. 4. In most of cases, the counterclockwise rotation was decreased in case of the direction of the force is $20^{\circ}$ downward to occlusal plane compared to the parallel direction. 5. At the point of force application is 15mm above and the direction of force is 20 downward to occlusal plane , the translation of the maxillary complex was showed. (Lateral view) 6. The direction of fringe patterns of the facial bones were differed each other by the sutures, and showed almost parallel when apply the 300gm and 500gm of protraction force. 7. In case of rapid palatal expansion with protraction of the maxilla, the fringe patterns between the maxillary area and the area from the posterior of the maxillary first molar to the pterygomaxillary fissure were differed. In case without rapid palatal expansion, the changes of direction and point of the force application did not affect to the direction and the number of the fringe patterns.

  • PDF

Regenerative capacity of augmented bone in rat calvarial guided bone augmentation model

  • Kubota, Tatsuya;Hasuike, Akira;Ozawa, Yasumasa;Yamamoto, Takanobu;Tsunori, Katsuyoshi;Yamada, Yutaka;Sato, Shuichi
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.77-85
    • /
    • 2017
  • Purpose: Guided bone regeneration (GBR) is the most widely used technique to regenerate and augment bones. Even though augmented bones (ABs) have been examined histologically in many studies, few studies have been conducted to examine the biological potential of these bones and the healing dynamics following their use. Moreover, whether the bone obtained from the GBR procedure possesses the same functions as the existing autogenous bone is uncertain. In particular, little attention has been paid to the regenerative ability of GBR bone. Therefore, the present study histologically evaluated the regenerative capacity of AB in the occlusive space of a rat guided bone augmentation (GBA) model. Methods: The calvaria of 30 rats were exposed, and plastic caps were placed on the right of the calvaria in 10 of the 30 rats. After a 12-week healing phase, critical-sized calvarial bone defects (diameter: 5.0 mm) were trephined into the dorsal parietal bone on the left of the calvaria. Bone particles were harvested from the AB or the cortical bone (CB) using a bone scraper and transplanted into the critical defects. Results: The newly generated bone at the defects' edge was evaluated using micro-computed tomography (micro-CT) and histological sections. In the micro-CT analysis, the radiopacity in both the augmented and the CB groups remained high throughout the observational period. In the histological analysis, the closure rate of the CB was significantly higher than in the AB group. The numbers of cells positive for runt-related transcription factor 2 (Runx2) and tartrate-resistant acid phosphatase (TRAP) in the AB group were larger than in the CB group. Conclusions: The regenerative capacity of AB in the occlusive space of the rat GBA model was confirmed. Within the limitations of this study, the regenerative ability of the AB particulate transplant was inferior to that of the CB particulate transplant.

DENTAL TREATMENT IN A PATIENT WITH HYDROCEPHALUS ASSOCIATED BRAIN TUMOR UNDER GENERAL ANESTHESIA (뇌종양과 연관된 수두증(hydrocephalus) 환자의 전신마취 하 치과치료)

  • Han, Jeong-Hwa;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.86-90
    • /
    • 2017
  • Hydrocephalus is characterized by accumulation of cerebrospinal fluid in the ventricles of the brain causing progressive ventricular dilatation. Accumulation of cerebrospinal fluid typically causes increased pressure inside the skull, this may result in headaches, vomiting, nausea, seizures, sleepiness and mental impairment. Patients with hydrocephalus may have dental manifestations such as changes in the occlusion and greater accumulation of plaque. The prevalence of dental caries is high due to the difficulty of oral care. The purpose of this case report is to describe the dental care for an uncooperative child with hydrocephalus under general anesthesia.