• 제목/요약/키워드: Skin thickness

검색결과 995건 처리시간 0.039초

전완유리피판 공여부 재건에서 전층 피부이식술과 부분층 피부이식술의 비교 (Comparison Study Between Coverage Choices for Radial Forearm Free Flap Donor Site)

  • 정우식;최종우;오태석
    • 대한두경부종양학회지
    • /
    • 제31권1호
    • /
    • pp.5-8
    • /
    • 2015
  • Backgrounds: The purpose of this study was to compare full thickness skin graft with inguinal skin to split thickness skin graft for coverage of the radial forearm free flap donor site. Patients and Methods: 25 patients who was reconstructed with radial forearm free flap for head and neck cancer were reviewed retrospectively. Results: The graft loss rates of full thickness skin graft were less than split thickness skin graft or split thickness skin graft with dermal substitutes. The recovery times of donor site and skin graft donor site of full thickness skin graft were also shorter than split thickness skin graft or split thickness skin graft with dermal substitutes. Skin texture and aesthetic results of donor site were improved and complications as itching and pain sensation were decreased. Conclusion: Full thickness skin grafts with inguinal skin should be considered for patients requiring a radial forearm free flap.

  • PDF

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • 제19권6호
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

Skin Thickness of the Anterior, Anteromedial, and Anterolateral Thigh: A Cadaveric Study for Split-Skin Graft Donor Sites

  • Chan, Jeffrey C.Y.;Ward, John;Quondamatteo, Fabio;Dockery, Peter;Kelly, John L.
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.673-678
    • /
    • 2014
  • Background The depth of graft harvest and the residual dermis available for reepithelization primarily influence the healing of split-skin graft donor sites. When the thigh region is chosen, the authors hypothesize based on thickness measurements that the anterolateral region is the optimal donor site. Methods Full-thickness skin specimens were sampled from the anteromedial, anterior, and anterolateral regions of human cadavers. Skin specimens were cut perpendicularly with a custom-made precision apparatus to avoid the overestimation of thickness measurements. The combined epidermal and dermal thicknesses (overall skin thickness) were measured using a digital calliper. The specimens were histologically stained to visualize their basement membrane, and microscopy images were captured. Since the epidermal thickness varies across the specimen, a stereological method was used to eliminate observer bias. Results Epidermal thickness represented 2.5% to 9.9% of the overall skin thickness. There was a significant difference in epidermal thickness from one region to another (P<0.05). The anterolateral thigh region had the most consistent and highest mean epidermal thickness ($60{\pm}3.2{\mu}m$). We observed that overall skin thickness increased laterally from the anteromedial region to the anterior and anterolateral regions of the thigh. The overall skin thickness measured $1,032{\pm}435{\mu}m$ in the anteromedial region compared to $1,220{\pm}257{\mu}m$ in the anterolateral region. Conclusions Based on skin thickness measurements, the anterolateral thigh had the thickest epidermal and dermal layers. We suggest that the anterolateral thigh region is the optimal donor site for split-skin graft harvests from the thigh.

Preparation of harvested skin using the Versajet Hydrosurgery System in full-thickness skin grafts

  • Choi, Seo Gil;Shin, Hyun Woo;Yoon, Kun Chul
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.603-607
    • /
    • 2019
  • During a full-thickness skin graft procedure, the thickness of the harvested donor skin is adjusted based on the location of the recipient site and the judgment of the surgeon. Conventionally, the thickness of the harvested skin is roughly adjusted using surgical instruments such as scalpels and scissors. However, this method is not only time-consuming, but also requires effort to obtain both the desired thickness of the harvested skin and a smooth surface of that skin. Moreover, there is a possibility of skin perforation. Hence, the authors devised a method of adjusting harvested skin thickness using the Versajet Hydrosurgery System. The Versajet device is a handheld hydrosurgical tool that delivers a high-speed jet stream of saline solution, which enables the precise debridement of tissue. This method makes it easier and faster for the surgeon to obtain the desired thickness of harvested skin. In addition, by obtaining a smooth surface and an even thickness of harvested donor skin, this technique may lead to improved graft viability.

초미세 발포 사출공정에서 금형의 온도가 스킨층 두께와 충격강도에 미치는 영향 (Influence of Mold Temperature on the Thickness of a Skin Layer and Impact Strength in the Microcellular Injection Molding Process)

  • 이정주;차성운
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1630-1635
    • /
    • 2005
  • The microstructure of the parts made by the microcellular injection molding process influence properties, including impact strength, tensile strength and density of material. Microstructure of microcellular plastics is divided into core foaming region and solid skin region. Core foaming region is influenced by pressure drop rate, viscosity and cell coalescence. However, actual mechanism of the skin layers is not known despite its importance. The study on the skin layer is getting important because foaming rate of the plastics is determined by the thickness ratio of the skin layer. Especially in case of large molded part, control of the skin layer is needed because skin layer thickness is changed largely. Therefore it is necessary to study variation in skin layer thickness with processing parameters. In this paper, the influence of temperatures in the mold cavity on the skin layer s thickness was also addressed. In addition, the relationship between the temperature distributions across cavity of the mold with impact strength on parts made with the microcellular injection molding process was addressed. In addition, the method to predict the variation in skin layer thickness with mold temperature is discussed.

  • PDF

손바닥피부주름을 이용한 전층피부이식술 (Full Thickness Skin Graft Using Palmar Crease)

  • 최요안;최환준;김준혁;이영만
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.829-835
    • /
    • 2011
  • Purpose: The two major concerns in skin grafting are poor color match in the recipient site and the donor site morbidity. And, glabrous skin on the palmar aspect of the hands and plantar aspect of the feet attributes define the skin on the palm and fingers sole as functionally and aesthetically different from skin on other parts of the body. When there is a glabrous skin defect, it should be replaced with similar skin to restore function and aesthetics. The palmar crease areas were used to minimize these problems. The purpose of this study is to present the precise surgical technique of the full thickness skin graft using distal palmar and midpalmar creases for aesthetic better outcome for hand injuries. Methods: From May 2006 to April 2010, 10 patients with 11 defects underwent glabrous full thickness skin grafting of finger defects. Causes included seven machinery injuries, two secondary burn reconstructions, and one knife injury. Donor sites included ten glabrous full thickness skin graft from the distal palmar crease and one from the midpalmar crease. Results: Follow-up ranged from 3 months to 24 months. All glabrous skin grafts demonstrated complete taking the recipient sites and no incidence of the complete or partial loss. The donor site healed without complications, and there were no incidences of significant hypopigmantation, hyperpigmentation, or hypertrophic scarring. Conclusion: The important aspects of this method involve immediate return of glabrous skin to the defect site and restoration of the recipient site's crease by simple primary closure from adjacent skin. The glabrous skin of the palm provides the best tissue match for the reconstruction of the hands, but only a limited amount of tissue is available for this purpose. Full thickness skin grafting using palmar crease of the defects is the ideal way of reconstructing glabrous skin to restore both function and aesthetics and minimize donor site morbidity.

손날 부위에서의 전층 피부이식을 이용한 수부 피복 (Hand Resurfacing with Full Thickness Skin Graft from the Palm Ulnar Border)

  • 송정윤;은석찬;백롱민
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.649-654
    • /
    • 2011
  • Purpose: Split-or full-thickness skin grafts are used to reconstruct palmar skin and soft tissue defects after trauma or to release burn scar contracture on the hand. Glabrous skin defects should be substituted with similar skin to preserve function and aesthetics. The authors report their experiences with a technique that uses a full-thickness graft taken from glabrous skin on the ulnar edge of the palm for the reconstruction of soft tissue defects of the hand. Methods: During a three-year period from 2007 to 2010, 22 patients with burn scar contracture and 12 patients with post-traumatic skin defects on their hands were treated with full-thickness skin graft operations. The palmar skin and soft tissue defects after release of burn scar contracture or debridement of post-traumatic wounds were reconstructed with full-thickness skin grafts harvested from the ulnar border of their palms. All donor-site wounds were primarily closed. Results: The followup periods ranged from 3 to 25 months. Contractures of the hand were corrected without recurrence, and the grafts showed relatively good contour and color match to the adjacent fields. There were no reported complications such as significant color change or hypertrophic scarring. The grafted skin showed an average 5.9 mm static two-point discrimination obtained in fingertip reconstruction cases, indicating satisfactory reinnervation. Conclusion: Glabrous full-thickness grafts harvested from the palmar ulnar border is a very useful way of reconstructing soft tissue defects on hands, including fingertips, for function restoration, favorable aesthetic results, and low donor-site morbidity.

상완내측 피부를 이용한 안면부의 부분층 식피술 (Split-thickness Skin Graft on the Face from the Medial Arm Skin)

  • 문성원;노복균;김의식;황재하;이삼용
    • Archives of Plastic Surgery
    • /
    • 제34권1호
    • /
    • pp.70-76
    • /
    • 2007
  • Purpose: Full-thickness skin grafts are usually used in facial reconstruction, but on occasion, split-thickness skin graft is also used from the scalp due to the limitation of donor site. However, there were complications, such as alopecia, folliculitis and blood loss. In addition, it can not be used in patients with baldness. Under the circumstances, we used medial arm skin as split-thickness skin graft donor site in lieu of scalp. We investigated the efficacy of the medial arm skin as a donor site of facial skin graft in comparison with scalp. Methods: From 2000 to 2005, the split-thicknesss skin grafts were performed using the medial arm skin in 10 patients and the scalp in 10 patients. We inspected the skin color match, texture match by the visual analogue scale. Scar contracture was estimated by the Visitrak $grade^{(R)}$(Smith & Nephew). The statistical analysis was performed by SPSS 12.0. Results: There was a more satisfaction in color match, texture, and scar contracture in medial arm skin than in scalp. Conclusion: According to these results, medial arm skin may be used efficiently as an alternative donor site of scalp in the facial reconstruction.

Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

  • Yang, Jung Dug;Cho, In Gook;Kwon, Joon Hyun;Lee, Jeong Woo;Choi, Kang Young;Chung, Ho Yun;Cho, Byung Chae
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.418-423
    • /
    • 2016
  • Background Skin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute. Methods This prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A), and RapiGraft and split-thickness skin grafting were used on the other side (group B). All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS), a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months. Results The skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082). Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all). However, the groups did not differ significantly in pliability (P=0.155). Conclusions The present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft

  • Lim, Hyoseob;Han, Dae Hee;Lee, Il Jae;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • 제41권2호
    • /
    • pp.126-132
    • /
    • 2014
  • Background Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. Methods We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Results Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. Conclusions A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.