• Title/Summary/Keyword: Skin occlusion

Search Result 47, Processing Time 0.03 seconds

The Relationship between Oxygen Saturation and Color Alteration of a Compromised Skin Flap: Experimental Study on the Rabbit

  • Prasetyono, Theddeus O.H.;Adianto, Senja
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.505-509
    • /
    • 2013
  • Background The aim of this study was to collect important data on the time of oxygen saturation change in relation to skin flap color alteration using non-invasive pulse oximetry to evaluate its ability to provide continuous monitoring of skin flap perfusion. Methods An experimental study on the monitoring of blood perfusion of 20 tube-island groin flaps of 10 male New Zealand rabbits was performed using pulse oximetry. The animals were randomly assigned to one of two groups representing a blockage of either arterial or venous blood flow. The oxygen saturation change and clinical color alteration were monitored from the beginning of vessel clamping until the saturation became undetectable. The result was analyzed by the t-test using SSPS ver. 10.0. Results The mean times from the vessel clamping until the saturation became undetectable were $20.19{\pm}2.13$ seconds and $74.91{\pm}10.57$ seconds for the artery and vein clamping groups, respectively. The mean time of the clinical alteration from the beginning of vein clamping was $34.5{\pm}11.72$ minutes, while the alteration in flaps with artery clamping could not be detected until 2.5 hours after clamping. Conclusions The use of neonate-type reusable flex sensor-pulse oximetry is objective and effective in early detection of arterial and vein blockage. It provides real-time data on vessel occlusion, which in turn will allow for early salvaging. The detection periods of both arterial occlusion and venous congestion are much earlier than the color alteration one may encounter clinically.

Acute Abdominal Aortic Occlusion after Open Heart Surgery - A case report - (개심술 후에 발생한 급성 복부 대동맥 차단 -1예 보고-)

  • Han, Won-Kyung;Cho, Joon-Yong;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.710-713
    • /
    • 2005
  • Acute abdominal Aortic occlusion is rare but it is a vascular emergency with high mortality and morbidity. There­fore, delay in diagnosis can have severe impact on the prognosis. A 60-year-old women complained of paresthesia, paralysis, and severe pain in bilateral lower extremities on 13th day after open heart surgery for mitral stenosis, atrial fibrillation, coronary arterial stenosis, tricuspid regurgitation, and atrial septal defect. Her skin was mottled and cool from the umbilicus to the feet, and there were no palpable pulses in the lower exteremities. We diagnosed an acute abdominal aortic occlusion using the Multi-Detector Row Spiral Computed Tomography and successfully treated the problem with emergent thrombo-embolectomy and Aortobifemoral bypass.

Real-Time Rotation-Invariant Face Detection Using Combined Depth Estimation and Ellipse Fitting

  • Kim, Daehee;Lee, Seungwon;Kim, Dongmin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.2
    • /
    • pp.73-77
    • /
    • 2012
  • This paper reports a combined depth- and model-based face detection and tracking approach. The proposed algorithm consists of four functional modules; i) color-based candidate region extraction, ii) generation of the depth histogram for handling occlusion, iii) rotation-invariant face region detection using ellipse fitting, and iv) face tracking based on motion prediction. This technique solved the occlusion problem under complicated environment by detecting the face candidate region based on the depth-based histogram and skin colors. The angle of rotation was estimated by the ellipse fitting method in the detected candidate regions. The face region was finally determined by inversely rotating the candidate regions by the estimated angle using Haar-like features that were robustly trained robustly by the frontal face.

  • PDF

Effect of Occlusion upon Rat Skin on the Activities of Cutaneous Oxygen Radical Metabolizing Enzymes in Rats

  • Han, Sun-Il;Yoon, Chong-Guk;Cho, Hyun-Gug
    • Biomedical Science Letters
    • /
    • v.7 no.2
    • /
    • pp.71-77
    • /
    • 2001
  • To evaluate the effect of occlusive skin on the activity of cutaneous oxygen free radical metabolizing enzymes in rats, the dorsal skin was covered with closed glass chamber shaped petri dish, 46 mm in diameter and 10 mm in height and sealed by an adhesive. Five day-occluded group showed more increased activity of xanthine oxidase (XO) than that of control, and the activity of five day-occluded group was higher than that of ten day-occluded group. The activities of superoxide dismutase (SOD) and glutathione peroxidase (GPx) were significantly higher in ten day-occluded group than in control or five day-occluded group. All the more, five day-occluded group showed the decreasing tendency of SOD and GPx activities compared to those of control. On the other hand, the cerrous perhydroxide deposits were observed in the intercellular space of the stratum basale in five day-occluded group under the electronic microscope using a cytochemistry method. Futhermore, the degree of cerrous perhydroxide reaction was lower in ten day-occluded group than in five day-occluded group. In conclusion, the increased XO activity and the decreased SOD and GPx activities are likely to responsible far the accumulation of $H_2O_2$ in five day-occluded group.

  • PDF

A Real-time Face Tracking Algorithm using Improved CamShift with Depth Information

  • Lee, Jun-Hwan;Jung, Hyun-jo;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2067-2078
    • /
    • 2017
  • In this paper, a new face tracking algorithm is proposed. The CamShift (Continuously adaptive mean SHIFT) algorithm shows unstable tracking when there exist objects with similar color to that of face in the background. This drawback of the CamShift is resolved by the proposed algorithm using Kinect's pixel-by-pixel depth information and the skin detection method to extract candidate skin regions in HSV color space. Additionally, even when the target face is disappeared, or occluded, the proposed algorithm makes it robust to this occlusion by the feature point matching. Through experimental results, it is shown that the proposed algorithm is superior in tracking performance to that of existing TLD (Tracking-Learning-Detection) algorithm, and offers faster processing speed. Also, it overcomes all the existing shortfalls of CamShift with almost comparable processing time.

Incidental finding of subclavian artery occlusion and subsequent hypoplastic internal mammary artery as a candidate recipient vessel in DIEP flap breast reconstruction

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.599-602
    • /
    • 2019
  • We report a case of autologous breast reconstruction in which a thoracodorsal vessel was used as a recipient vessel after a hypoplastic internal mammary vessel was found on preoperative computed tomography (CT) angiography. A 46-year-old woman with no underlying disease was scheduled to undergo skin-sparing mastectomy and breast reconstruction using a deep inferior epigastric artery perforator flap. Preoperative CT angiography showed segmental occlusion of the right subclavian artery with severe atherosclerosis and calcification near the origin of the internal mammary artery, with distal flow maintained by collateral branches. The thoracodorsal artery was selected to be the recipient vessel because CT showed that it was of adequate size and was not affected by atherosclerosis. The patient experienced no postoperative complications, and the flap survived with no vascular complications. The breasts were symmetrical at a 6-month follow-up. This case highlights that preoperative vascular imaging modalities may help surgeons avoid using diseased vessels as recipient vessels in free flap breast reconstructions.

Real-Time Human Tracking Using Skin Area and Modified Multi-CAMShift Algorithm (피부색과 변형된 다중 CAMShift 알고리즘을 이용한 실시간 휴먼 트래킹)

  • Min, Jae-Hong;Kim, In-Gyu;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1132-1137
    • /
    • 2011
  • In this paper, we propose Modified Multi CAMShift Algorithm(Modified Multi Continuously Adaptive Mean Shift Algorithm) that extracts skin color area and tracks several human body parts for real-time human tracking system. Skin color area is extracted by filtering input image in predefined RGB value range. These areas are initial search windows of hands and face for tracking. Gaussian background model prevents search window expending because it restricts skin color area. Also when occluding between these areas, we give more weights in occlusion area and move mass center of target area in color probability distribution image. As result, the proposed algorithm performs better than the original CAMShift approach in multiple object tracking and even when occluding of objects with similar colors.

Human Body Tracking and Pose Estimation Using CamShift Based on Kalman Filter and Weighted Search Windows (칼만 필터와 가중탐색영역 CAMShift를 이용한 휴먼 바디 트래킹 및 자세추정)

  • Min, Jae-Hong;Kim, In-Gyu;Hwang, Seung-Jun;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.3
    • /
    • pp.545-552
    • /
    • 2012
  • In this paper, we propose Modified Multi CAMShift Algorithm based on Kalman filter and Weighted Search Windows(KWMCAMShift) that extracts skin color area and tracks several human body parts for real-time human tracking system. We propose modified CAMShift algorithm that generates background model, extracts skin area of hands and head, and tracks the body parts. Kalman filter stabilizes tracking search window of skin area due to changing skin area in consecutive frames. Each occlusion areas is avoided by using weighted window of non-search areas and main-search area. And shadows are eliminated from background model and intensity of shadow. The proposed KWMCAMShift algorithm can estimate human pose in real-time and achieves 96.82% accuracy even in the case of occlusions.

A Real-Time Face Detection/Tracking Methodology Using Haar-wavelets and Skin Color (Haar 웨이블릿 특징과 피부색 정보를 이용한 실시간 얼굴 검출 및 추적 방법)

  • Park Young-Kyung;Seo Hae-Jong;Min Kyoung-Won;Kim Joong-Kyu
    • The KIPS Transactions:PartB
    • /
    • v.13B no.3 s.106
    • /
    • pp.283-294
    • /
    • 2006
  • In this paper, we propose a real-time face detection/tracking methodology with Haar wavelets and skin color. The proposed method boosts face detection and face tracking performance by combining skin color and Haar wavelets in an efficient way. The proposed method resolves the problem such as rotation and occlusion due to the characteristic of the condensation algorithm based on sampling despite it uses same features in both detection and tracking. In particular, it can be applied to a variety of applications such as face recognition and facial expression recognition which need an exact position and size of face since it not only keeps track of the position of a face, but also covers the size variation. Our test results show that our method performs well even in a complex background, a scene with varying face orientation and so on.

The Observation of the Skin Contact Allergic Sensitization Test of Rhus-II with Guinea Pig Maximization Test (Guinea Pig Maximization Test에 의한 옻나무 추출액(Rhus-II)의 접촉 알러지성 자극에 관한 연구)

  • Choi Changsun;Han Dong Un
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • The purpose of the present study was to investigate differences in the sensitizing potential of Rhus Veniciflua(Rhus-II), when tested by the guinea pig maximization test(GPMT) and Freund's complete adjuvant test(FCAT) with an identical, intradermal induction concentration. A new grading classification of the sensitization potential is proposed. The GPMT was conducted according to OECD guideline $\#406$, using a multiple-dose design and test results were analysed with logistic regression analysis. During the induction stage, we injected intradermally each three site 0.1 ml(l mg/animal) test material, 0.1 ml complete Freund's adjuvant and 0.lml the test agent emulsified in the adjuvant. 7 days later, we induced weak sensitization with $10\%$ sodium lauryl sulfate(SLS) and applide 1ml(l0mg/animal) test agent topically on the same site and made a tight occlusion. 14 days later we challenged with 1 ml(l 0mg/animal) of test material on the flank and observed ant 24 hours and 48 hours later. The results were also observed $0\%$ at 24 hours challenge. The results observed 48 hours after challenge were the identical. These data indicated that, although Rhus-II is a no contact allergen. It was reported that the skin sensitization by Rhus-II was not detected the skin sensitization in the guinea pig maximization test (GPMT). Consequently, it was confirmed that Rhus-II had no contact allergic sensitization in guinea pig maximization test.