• 제목/요약/키워드: Skin motion

검색결과 230건 처리시간 0.021초

Effects of Skin Mobilization on Pain and Joint Range Improvement in Patients with Axillary Web Syndrome: A Single Case Report

  • Choi, Suhong;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권2호
    • /
    • pp.112-115
    • /
    • 2021
  • Objective: This study was conducted to apply skin mobilization to patients with Axillary web syndrome following breast cancer resection and to see the resulting changes in pain and joint range of motion. Design: Single case study,pre-post comparison. Methods: The subject was a female patient in her 40s who performed a mastectomy after being diagnosed with breast cancer, and then complained of uncomfortable pain from the shoulder joint to the axilla and limited range of motion. To implement a skin mobilization, the palms were adhered to the inner half of the arm, the arms were raised to a pain-free extent, and skin mobilization was performed. The skin was pulled in the direction of axilla and kept for 5 seconds 10 times for a total of 2 sets. Immediate changes in range of motion and pain were identified. Results: Following skin mobilization, there was an immediate increase in range of motion (pre 116°, post 140°) and a decrease in pain (NRS pre 5, post 2). And also uncomfortable pain, which is hard to define in words, also seems to have improved. Conclusions: Skin mobilization, which considers skin mobility for patients with Axillary web syndrome, can be considered for improving range of motion and restoring function in patients with pain due to fibrous bands around veins and lymphatic vessels, and is recommended as a new intervention method not used as a conventional treatment.

연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용 (Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact)

  • 류태범
    • 산업경영시스템학회지
    • /
    • 제35권4호
    • /
    • pp.24-32
    • /
    • 2012
  • Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods, two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.

Effects of Active Movement with Skin Mobilization on Range of Motion, Pain, RPE on Patients with Axillary Web Syndrome: A Case Study

  • Su-Hong Choi
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.430-435
    • /
    • 2022
  • Objective: This study was conducted to investigate the effect of active movement with skin mobilization on range of motion, pain, and rating of perceived exertion in patients diagnosed with axillary web syndrome after axillary lymph node dissection. Design: A Case report Methods: It was performed on 7 patients diagnosed with axillary web syndrome after lymph node dissection. The subjects experienced a decrease in the range of joint motion and pain in movement when raising their arms in their daily lives, and complained of discomfort. The active range of motion, numeric rating scale, and modified Borg scale of shoulder joint flexion were measured, and the differences after active movement with skin mobilization were compared. Results: All subjects increased by 24.9 degree on average in active range of motion after active movement with skin mobilization intervention. There was no pain in the maximum range of joint motion measured before intervention, and rating of perceived exertion was significantly reduced. Conclusions: Active movement with skin mobilization can be a very useful way to help improve and treat axillary web syndrome, and it is recommended for improving the function and quality of life of axillary web syndrome patients. and It is also believed that it can be used steadily at home through the education of patients and families.

체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구 (A Study of Sensing Locations for ECG Monitoring Clothing based on the Skin Change rate)

  • 조하경;조상우
    • 한국의류산업학회지
    • /
    • 제17권5호
    • /
    • pp.844-853
    • /
    • 2015
  • Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20' with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

칼라 참조 맵과 움직임 정보를 이용한 얼굴영역 추출 (Facial region Extraction using Skin-color reference map and Motion Information)

  • 이병석;이동규;이두수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 제14회 신호처리 합동 학술대회 논문집
    • /
    • pp.139-142
    • /
    • 2001
  • This paper presents a highly fast and accurate facial region extraction method by using the skin-color-reference map and motion information. First, we construct the robust skin-color-reference map and eliminate the background in image by this map. Additionally, we use the motion information for accurate and fast detection of facial region in image sequences. Then we further apply region growing in the remaining areas with the aid of proposed criteria. The simulation results show the improvement in execution time and accurate detection.

  • PDF

자기공명 영상을 이용한 피부 움직임 에러 분석에 관한 연구 (Analysis of Skin Movement Artifacts Using MR Images)

  • 류재헌;;;;이관행
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.164-170
    • /
    • 2004
  • The skin movement artifacts are referred to as the relative motion of skin with respect to the motion of underlying bones. This is of great importance in joint biomechanics or internal kinematics of human body. This paper describes a novel experiment that measures the skin movement of a hand based on MR(magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images, and (3) registration of the 3D models. The MR images of the hand are captured by 3 different postures. And the surface makers which are attached to the skin are employed to trace the skin motion. After reconstruction of 3D models from the scanned MR images, the global registration is applied to the 3D models based on the particular bone shape of different postures. The results of registration are then used to trace the skin movement by measuring the positions of the surface markers.

피부의 움직임을 이용한 표적의 위치 추정에 관한 가능성 연구 - 동물 실험 (A Feasibility Study on the Prediction of the Target in the Lung from the Skin Motion - Animal Study)

  • 서예린;이병용;신승애;김종훈;안승도;이상욱;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.163-168
    • /
    • 2002
  • 흉곽 내 종양의 방사선 치료를 계획함에 있어, 피부의 움직임을 관찰하여 호흡에 의한 종양의 이동 범위를 추정하는 예비 연구로서 동물 실험을 시행하였다. 실험 동물로는 20 kg 크기의 황구를 이용하였고, 폐의 움직임과 피부의 움직임을 비교하기 위하여 형광투시경과 CCD 카메라를 동시에 이용할 수 있는 시스템을 자체 제작하였다. 폐의 하엽에 해당하는 부위의 피부 위에 방사선에 비투과성인 표시점을 올려놓고, 형광투시경으로 전면과 측면에서 상엽과 하엽의 움직임을 측정하였다. 동시에, CCD 카메라로부터 피부 움직임의 영상을 저장하여 두 개의 측정 결과를 비교하였다. 피부는 진폭 6 mm의 주기로 움직이고, 폐 안의 표적도 운동의 진폭(최대 15 mm)과 방향이 폐의 움직임을 따라 변하는 동안 거의 같은 주기로 움직이는 것이 관찰되어, 피부 위의 표시점과 실제 움직이는 표적은 평균 0.85 이상의 강한 상관 관계가 있음을 알 수 있었다. 이러한 상관 관계로 볼 때, 피부의 움직임으로부터 호흡에 의해 움직이는 폐 내부 종양의 위치를 예측하는 것이 가능함을 알 수 있었다. 동물 실험의 경우 호흡에 의한 피부의 움직임으로부터 정확한 표적의 위치를 예측하는 것이 가능하였고, 이 방법을 실제 환자에서도 응용할 수 있는 가능성이 있음을 보였다.

  • PDF

A numerical method for improving the reliability of knee translation measurement in skin marker-based motion analysis

  • Wang, Hongsheng;Zheng, Nigel
    • Advances in biomechanics and applications
    • /
    • 제1권4호
    • /
    • pp.269-277
    • /
    • 2014
  • In skin-marker based motion analysis, knee translation measurement is highly dependent on a pre-selected reference point (functional center) on each segment determined by the location of anatomical landmarks. However, the placement of skin markers on palpable anatomical landmarks (i.e., femoral epicondyles) has limited reproducibility. Thus, it produces large variances in knee translation measurement among different subjects, as well as across studies. In order improve the repeatability of knee translation measurement, in this study an optimization method was introduced, by which the femoral functional center was numerically determined. At that point the knee anteroposterior translation during the stance phase of walking was minimized. This new method was tested on 30 healthy subjects during walking in gait lab with motion capture system. Using this new method, the impact of skin marker position (at anatomical landmarks) on the knee translation measurement has been minimized. In addition, the ranges of anteroposterior knee translations during stance phase were significantly (p<0.001) smaller than those measured by conventional method which relies on a pre-selected functional center ($11.1{\pm}3.5mm$ vs. $19.9{\pm}5.5mm$). The results of anteroposterior translation using this new method were very close to a previously reported knee translation (12.4 mm) from dual fluoroscopic imaging technique. Moreover, this new method increased the reproducibility of knee translation measurement by 50%.

Analysis of Skin Movements with Respect to Bone Motions using MR Images

  • Ryu, Jae-Hun;Miyata, Natsuki;Kouchi, Makiko;Mochimaru, Masaaki;Lee, Kwan H.
    • International Journal of CAD/CAM
    • /
    • 제3권1_2호
    • /
    • pp.61-66
    • /
    • 2003
  • This paper describes a novel experiment that measures skin movement with respect to the flexional motion of a hand. The study was based on MR images in conjunction with CAD techniques. The MR images of the hand were captured in 3 different postures with surface markers. The surface markers attached to the skin where employed to trace skin movement during the flexional motion of the hand. After reconstructing 3D isosurfaces from the segmented MR images, the global registration was applied to the 3D models based on the particular bone shape of different postures. Skin movement was interpreted by measuring the centers of the surface markers in the registered models.

Reconstructing individual hand models from motion capture data

  • Endo, Yui;Tada, Mitsunori;Mochimaru, Masaaki
    • Journal of Computational Design and Engineering
    • /
    • 제1권1호
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we propose a new method of reconstructing the hand models for individuals, which include the link structure models, the homologous skin surface models and the homologous tetrahedral mesh models in a reference posture. As for the link structure model, the local coordinate system related to each link consists of the joint rotation center and the axes of joint rotation, which can be estimated based on the trajectories of optimal markers on the relative skin surface region of the subject obtained from the motion capture system. The skin surface model is defined as a three-dimensional triangular mesh, obtained by deforming a template mesh so as to fit the landmark vertices to the relative marker positions obtained motion capture system. In this process, anatomical dimensions for the subject, manually measured by a caliper, are also used as the deformation constraints.