• Title/Summary/Keyword: Skin interest

Search Result 243, Processing Time 0.024 seconds

The Background and Current Research Applied to Development of Korean Cosmetics Based on Traditional Asian Medicine (한국 한방화장품 발달 배경 및 연구 현황)

  • Cho, Gayoung;Park, Hyomin;Choi, Sowoong;Kwon, Leekyung;Cho, Sunga;Suh, Byungfhy;Kim, Namil
    • The Journal of Korean Medical History
    • /
    • v.30 no.2
    • /
    • pp.63-71
    • /
    • 2017
  • Traditional Asian medicine has an extensive evidence base built upon thousands of years of experience within Asia, of curing various diseases. Only recently, within the past two centuries, have modern medical scientists developed interest in traditional Asian medicine. Asian Medicine seems to be regarded only as an adjunctive medicine and viewed as alargely un-proven alternative medicine to complement western medicine, used in some cases to establish a new paradigm of "integrative medicine". This article reviews how Korean herbal cosmetics emerged by applying traditional Asian medicine to the science of cosmetics. The characteristics of Korean herbal cosmetics are examined through examples of history, concepts and traditions. With the advancements in biotechnology, studies are now being conducted on the dermatological effects and processing methods of herbal ingredients, including ginseng. The authors explain the current research on the identification on the active ingredients of herbs, extraction methods, and bio-processing of ingredients to improve the biological efficacies of herbs on the skin. A summary of studies focused on modern reinterpretations of ageing theories, such as 'Seven year aging cycle', are provided. In conclusion, the development of Korean cosmetics products are based on the accumulated knowledge of thousands of years of experience including; 1) practical heritage of traditional Asian medicines such as Donguibogam; 2) excellent medicinal plants, such as ginseng, which are native to Korea; and 3) innovative attempts to modernize materials, processes, and principles.

BioPebble: Stone-type physiological sensing device Supporting personalized physiological signal analysis (BioPebble: 개인화된 해석을 지원하는 돌 타입 휴대용 생체신호 측정센서)

  • Choi, Ah-Young;Park, Go-Eun;Woo, Woon-Tack
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.13-18
    • /
    • 2008
  • In these days, wearable and mobile physiological sensing devices have been studied according to the increasing interest on the healthy and wellbeing life. However, these sensing devices display just the sensing results, such as heart rate, skin temperature, and its daily records. In this work, we propose the novel type of mobile physiological sensing device which deliver the user comfortable grabbing feeling. In addition, we indicate the personalized physiological signal analysis result which be concluded by the different analysis results according to the person to person. In order to verify this sensing device, we collect the data set from 4 different users during a week and measure the physiological signal such as heart rate, hand temperature, and skin conductance. And we observe the result how the analysis results shows the difference between the users. We expect that this work can be applied in the various health care applications in the near future.

  • PDF

A Study on Sociocultural Attitudes and Appearance Management Behavior in accordance with Gender Role Identity

  • Park, Eun-Hee
    • Journal of Fashion Business
    • /
    • v.16 no.3
    • /
    • pp.107-124
    • /
    • 2012
  • The purpose of this study was to classify types in sense of gender role identity and to figure out the difference among sociocultural attitude, benefits of clothing pursuit, and appearance management behaviors by sense of gender role identity types. Questionnaires were administered to 455 people in their twenties and thirties living in Daegu and Kyoungbuk area. Data were analyzed by using frequency, factor analysis, credibility, $X^2$-test, ANOVA, Duncan-test, and t-test. The findings are as follows. First, Men of androgyny group showed the highest rate of 38.5% followed by undifferentiation(22.9%), masculineness(21.0%), and feminineness(17.6%). Women of undifferentiation group showed the highest rate of 33.2% followed by feminineness (25.2%), androgyny(22.0%), and masculineness(19.6%). Second, factors of sociocultural attitude were internalization and recognition. Benefits of clothing pursuit consists of the factors such as consciousness of others, personality, and vogue pursuit. Factors of appearance management behaviors were dressing, skin management, plastic surgery management, weight management, health management, and hair management. Third, the result from the difference between sociocultural attitude and benefits of clothing pursuit by sense of gender role identity types, men of androgyny and feminineness showed highest in recognition while women of androgyny showed highest in internalization and recognition. The result of the difference in benefits of clothing pursuit by sense of gender role identity shows that both men and women of androgyny group have high tendency for being conscious of others, personality pursuit, and vogue pursuit while men of undifferentiation and masculineness have low interest in dressing in relationship with others. Fourth, the examination of the difference in appearance management behavior by sense of gender role identity types found men of androgyny group managed dressing, skin, weight, health and hair most while women dress and health most. Men of undifferentiation group managed dressing and weight least, while men of masculineness health, and men of feminineness hair least.

Comparison of absorption based on the location of seam of cloth diaper

  • Lee, Heeran;Lee, Hyojeong;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.20 no.6
    • /
    • pp.94-110
    • /
    • 2016
  • A necessity for infants, diapers are not only used over long durations, but are also in direct contact to the infants' skin, making the choice of diaper to be of utmost importance. Current interest in cloth diapers is rapidly increasing because of issues concerning the baby's health, green environment, and economy. However, previous researches on cloth diapers are limited to simply investigating the form and material of commercial cloth diapers. There are few in-depth researches for the optimal cloth diaper development. This is therefore a fundamental research for the development of optimized cloth diapers, and analyzes the difference in absorption depending on the placement of seam line (liner, darts, and I pattern), the locations of liquid spraying (1 cm and 8 cm ahead of the center), and the amount of liquid capacity (10 and 20 ml). Currently, the development of diaper patterns considers the crotch shape of the infants and the skin length deformation. As a result, in the case of the I-pattern, the horizontal seam line prevents water from spreading to the front and back, thus reducing the absorbed area. This result was more clearly visible when water was sprayed at the center. The effect of the seam line became more obvious when there was more water (20 ml); also, when water was sprayed at the center, more leakage was observed. Using the results of this research, implementation of horizontal seam is expected to prevent the upward spread of urine.

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Face Region Tracking Improvement and Hardware Implementation for AF(Auto Focusing) Using Face to ROI (얼굴을 관심 영역으로 사용하는 자동 초점을 위한 얼굴 영역 추적 향상 방법 및 하드웨어 구현)

  • Jeong, Hyo-Won;Ha, Joo-Young;Han, Hag-Yong;Yang, Hoon-Gee;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • In this paper, we proposed a method about improving face tracking efficiency of face detection for AF system using the faces to the ROI. The conventional face detection system detecting faces based skin color uses the ratio of skin pixels of the present frame to detected face regions of the past frame to track the faces. The tracking method is superior in the stability of the regions but it is inferior in the face tracking efficiency. We proposed a face tracking method using the area of the overlapping region in the detected face regions of the past frame and the present frame to improve the tracking efficiency. The proposed face tracking efficiency demonstration was performed by making a film of face detection with face tracking in real-time and using the moving traces of the detected faces.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

Fabrication of Microwave Applicator for Hyperthermia and Thermal Distribution in Tissues (종양의 온열치료를 위한 마이크로잔 조사장치의 제작과 응용)

  • Chu S. S.;Lee J. T.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is bases on radiobiological and clinical evidence indicated that there may be a significant therapeutic advantage with the use of heat alone or combined with radiation or chemotherapy, There are many methods for generating heat for localized tumor as like radiofrequency, microwave, electromagnetic induction and ultrasound. But it is very difficult to be even thermal dose distribution and stable output of power and then the detection of temperature in tumor is difficult to be precise with thermocouples and semiconductor sensors. We designed the microwave heating generator, dipole antenna applicators and autometic temperature controlled thermocouples for localized hyperthermia on skin and in cavities. 1. The microwave generator with 120 W, 2,450MHz magnetron could be heating up to $40^{\circ}C\~50^{\circ}C\;for\;1\~2$ hours in living tissues. 2. The thermal dose distribution in tissue with microwave was described $42^{\circ}C\~44^{\circ}C$ with in 3 cm depth and $2\~6cm$ diameter area. 3. Skin surface heating applicator with spiral 3 times wave length antenna radiated high Power of microwave. 4, Intracavitary heating applicator with dipole antenna with autometic control temperature sensor kept up continuously constant temperature in tissue. 5. For constant thermal distribution, applied two steps power with 10W microwave after $17\~20W$ during first 10 minutes. 6. The cooling rate by blood flew in living tissue was rised as $10\%$ then meats.

  • PDF

A Numerical Study on Various Energy and Environmental System (II) (에너지${\cdot}$환경 제반 시스템에 관한 수치해석적 연구(II))

  • Jang D. S.;Park B. S.;Kim B. S.;Lee E. J.;Song W. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.58-67
    • /
    • 1996
  • This paper describes some computational results of various energy and environmental systems using Patankar's SIMPLE method. The specific topics handled in this study are jet bubbling reactor for flue gas desulfurization, cyclone-type afterburner for incineration, 200m tall stack for 500 MW electric power generation, double skin and heat storage systems of building energy saving for the utilization of solar heating, finally turbulent combustion systems with liquid droplet or pulverized coal particle. A control-volume based finite-difference method with the power-law scheme is employed for discretization. The pressure-velocity coupling is resolved by the use of the revised version of SIMPLE, that is, SIMPLEC. Reynolds stresses are closed using the standard $k-{\varepsilon}$ and RNG $k-{\varepsilon}$ models. Two-phase turbulent combustion of liquid drop or pulverized coal particle is modeled using locally-homogeneous, gas-phase, eddy breakup model. However simple approximate models are incorporated for the modeling of the second phase slip and retardation of ignition without consideration of any detailed particle behavior. Some important results are presented and discussed in a brief note. Especially, in order to make uniform exit flow for the jet bubbling reactor, a well-designed structure of distributor is needed. Further, the aspect ratio in the double skin system appears to be one of important factors to give rise to the visible change of the induced air flow rate. The computational tool employed in this study, in general, appears as a viable method for the design of various engineering system of interest.

  • PDF

The Alar Extension Graft for Retracted Ala (Alar Extension Graft를 이용한 콧방울뒤당김의 교정)

  • Kim, Hyun soo;Roh, Si Gyun
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.66-74
    • /
    • 2009
  • Purpose: The importance of the deformities in alar - columellar complex has been underestimated in Asian ethnic groups for the last decades. Fortunately, with increasing familiarity of the open rhinoplasty techniques, the anatomic details of the nasal tip have been pointed up. Definitely, having an interest and demand for improving the sub - normal relationship between the alar rim and columella are indebted for such growing of knowledge about nasal tip anatomy. However, it is true that any single procedure is not settled as versatile and fully confident modality to correct the retracted notching of the alar rim. With this article, I should like to propose another useful option for treating retracted ala. Methods: The author has tried to correct alar rim retraction by means of: (1) Triangular onlay septal cartilage graft on the lower lateral cartilage with the medial end fixed to the anterior surface of the lateral crus(Alar extension graft), (2) Inserting lateral end of the alar extension graft to the vestibular skin pocket in the form of a finger - in - groove, (3) using the vestibular skin in the form of an advancement flap, and (4) using the soft shield graft to prevent possible visible step - off of the alar margin. Results: The author applied an alar extension graft to 16 patients in order to correct a retracted ala for the last 27 months (August, 2003 - October, 2005). The distances from alar rim to long axis of nostril were improved to be within 2 mm in all of the cases, and also the shape of the alar rim changed to a round form. Nostril asymmetry (6%) in one case, temporary palpable step - off (18%) in three cases, temporary visible step - off (6%) in one case, and temporary paresthesia of the tip (25%) in four cases were observed. Conclusion: The alar extension graft is simple and efficacious. It does not need donor sites other than the operative field, and its results are predictable. In particular, since it may give structural intensity to a weak lower lateral cartilage, it may be preferentially used for the correction of a retracted ala that arises from hypoplastic lower lateral cartilage. Moreover intensified lower lateral cartilage also improves the esthetic shape of lobule.