• Title/Summary/Keyword: Skin Tests

Search Result 595, Processing Time 0.021 seconds

The Masking Effect According in Olfactory Stimulus on Horns Stimulus While Driving in Graphic Driving Simulator (화상 자동차 시뮬레이터에서 운전 중에 경적음 자극에 대한 후각자극의 마스킹 효과)

  • Min, Cheol-Kee;Ji, Doo-Hwan;Ko, Bok-Soo;Kim, Jin-Soo;Lee, Dong-Hyung;Ryu, Tae-Beum;Shin, Moon-Soo;Chung, Soon-Cheol;Min, Byung-Chan;Kang, Jin-Kyu
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.4
    • /
    • pp.227-234
    • /
    • 2012
  • In this study, the masking effect of olfactory stimulus on the awakening state due to sound stimuli while driving using Graphic Driving Simulator was observed through the response of autonomic nervous system. The test was conducted for 11 males in their twenties. The siren of ambulance car was presented to them as auditory stimulus for 30 secs while driving in a situation of high way in the condition of both peppermint and control, respectively, and LF/HF ratio of HRV (Heart Rate Variability), the activity index of sympathetic nerve, and GSR (Galvanic Skin Response) response were examined. The test was proceeded in the order of three stages, that is, sound stimuli (test 1), driving performance, and sound stimuli (test 2), and fragrance stimulus, driving performance, and sound stimuli (test 3), and the physiological signal of GSR, HRV was measured in the whole stages. As a result of test, comparing the results of before and after auditory stimulus test (1) (p < 0.01), test (2) (p < 0.05), and test (3) (p < 0.01), driving performance test (2) (p < 0.01), test (3) (p < 0.01), and olfactory stimulus test (3) (p < 0.05), respectively, GSR response increased, showing significant difference in all the tests. It indicates that when auditory stimulus was presented to the subjects, they were in the awakening state as sympathetic nervous system got activated. As a result of comparing auditory stimulus while driving before and after presenting olfactory stimulus, there was no significant difference in GSR response. The LF/HF ratio of HRV increased, showing a significant difference only in test (2) (p < 0.05), and in driving performance test (2) (p < 0.05) in auditory stimulus, however, it showed no significant difference in olfactory stimulus. As a result of comparing auditory stimulus while driving before and after presenting olfactory stimulus, there was a decrease, showing significant difference (p < 0.05) in LF/HF ratio of HRV. That is, it means that the activation of sympathetic nervous system decreased, and that parasympathetic nervous system got activated. From these results, it was observed that while driving, the awakening level due to auditory stimulus was settled with olfactory stimulus. In conclusion, it was drawn that while driving, olfactory stimulus could have the masking effect on auditory stimulus.

Estimation of resistance coefficient of PHC bored pile by Load Test II (재하시험에 의한 PHC 매입말뚝의 저항계수 산정 II)

  • Park, Jong-Bae;Park, Yong-Boo;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • In Europe and the United States, the use of limit states design has almost been established for pile foundation design. According to the global trend, the Ministry of Land, Transport and Maritime Affairs has established the basic design criteria of the bridge under the limit state design method. However, it is difficult to reflect on the design right now because of lack of research on resistance coefficient of the pile method and ground condition. In this study, to obtain the resistance coefficient of PHC bored pile which is widely used in Korea, the bearing capacity calculated by the LH design standard and the bridge design standard method, the static load test(21 times) and the dynamic load test(EOID 21 times, Restrike 21) The reliability analysis was performed on the results. The analysis of the resistance coefficient of PHC bored pile by loading test was analyzed by adding more than two times data. As a result, the resistance coefficient obtained from the static load test(ultimate bearing capacity) was 0.64 ~ 0.83 according to the design formula and the target reliability index, and the resistance coefficient obtained from the dynamic load test(ultimate bearing capacity) was 0.42~0.55. Respectively. The resistance coefficient obtained from the modified bearing capacity of dynamic load test(EOID's ultimate end bearing capacity + restrike's ultimate skin bearing capacity) was 0.55~0.71, which was reduced to about 14% when compared with the resistance coefficient obtained by the static load test(ultimate bearing capacity). As a result of the addition of the data, the resistivity coefficient was not changed significantly, even if the data were increased more than 2 times by the same value or 0.04 as the previous resistance coefficient. In conclusion, the overall resistance coefficient calculated by the static load test and dynamic load tests in this study is larger than the resistance coefficient of 0.3 suggested by the bridge design standard(2015).

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Study on the Mechanism of Manifestation of Ecological Toxicity in Heavy Metal Contaminated Soil Using the Sensing System of Earthworm Movement (지렁이 움직임 감지 시스템을 이용한 중금속 오염 토양의 생태독성 발현 메커니즘에 대한 연구)

  • Lee, Woo-Chun;Lee, Sang-Hun;Jeon, Ji-Hun;Lee, Sang-Woo;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.3
    • /
    • pp.399-408
    • /
    • 2021
  • Natural soil was artificially contaminated with heavy metals (Cd, Pb, and Zn), and the movement of earthworm was characterized in real time using the ViSSET system composed of vibration sensor and the other components. The manifestation mechanism of ecological toxicity of heavy metals was interpreted based on the accumulative frequency of earthworm movement obtained from the real-time monitoring as well as the conventional indices of earthworm behavior, such as the change in body weight before and after tests and biocumulative concentrations of each contaminant. The results showed the difference in the earthworm movement according to the species of heavy metal contaminants. In the case of Cd, the earthworm movement was decreased with increasing its concentration and then tended to be increased. The activity of earthworm was severely increased with increasing Pb concentration, but the movement of earthworm was gradually decreased with increasing Zn concentration. The body weight of earthworm was proved to be greatly decreased in the Zn-contaminated soil, but it was similarly decreased in Cd- and Pb-contaminated soils. The bioaccumulation factor (BAF) was higher in the sequence of Cd > Zn > Pb, and particularly the biocumulative concentration of Pb did not show a clear tendency according to the Pb concentrations in soil. It was speculated that Cd is accumulated as a metallothionein-bound form in the interior of earthworm for a long time. In particular, Cd has a bad influence on the earthworm through the critical effect at its higher concentrations. Pb was likely to reveal its ecotoxicity via skin irritation or injury of sensory organs rather than ingestion pathway. The ecotoxicity of Zn seemed to be manifested by damaging the cell membranes of digestive organs or inordinately activating metabolism. Based on the results of real-time monitoring of earthworm movement, the half maximal effective concentration (EC50) of Pb was estimated to be 751.2 mg/kg, and it was similar to previously-reported ones. The study confirmed that if the conventional indices of earthworm behavior are combined with the results of newly-proposed method, the mechanism of toxicity manifestation of heavy metal contaminants in soils is more clearly interpreted.

Clinical Findings of Mycoplasma pneumoniae pneumonia under 3 Year-Old Children (3세 이하 Mycoplasma pneumoniae 폐렴환자의 임상적 고찰)

  • Lee, Sung-Soo;Youn, Kyung-Lim;Kang, Hyeon-Ho;Cho, Byoung-Soo;Cha, Sung-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.1
    • /
    • pp.78-85
    • /
    • 1999
  • Purpose : Mycoplasma pneumoniae pneumonia has been to be developed frequently in school age children and adolescence and hard to see under 3 year-old children. But it seems to be increased in number of patients with Mycoplasma pneumoniae pneumonia under 3-year old in clinical practice in these days. We have aimed to examine the characteristics of clinical findings of Mycoplasma pneumonia under 3 year-old children. Methods : We had performed retrospective review of medical records of 30 patients with Mycoplasmal pneumonia under 3-year old children who admitted to Department of Pediatrics, Kyunghee University Hospital from Jan. 1994 to Dec. 1997. The diagnostic criteriae was Cold agglutinin titer>1:64 or Mycoplasma antibody titer>1:80. Results : Mycoplasmal pneumonia was 30 out of 235 cases(12.7%) of total pneumonia under 3 year old children. Male female ratio was 1.3 : 1 and age distributions were 0~1y : 0, 1~2y : 8, 2~3y : 22 cases. Clinical symptoms and signs were cough(100.0%), sputum(83.3%), fever(80.0%) rhinorrhea(33.3%), vomiting(33.3%), moist rale(86.7%), decreased breathing sound(26.7%), wheezing(20.0%), and pharyngeal injection(30.0%). Thirteen out of 30 cases(43.3%) had unilateral infiltration, 10 cases(33.4%) had bilateral infiltration, 1 case(3.3%) had pleural effusion, and 6 cases(20.0%) had negative findings on chest radiography and there was no cases of atelectasis. On laboratory findings, 6 out of 30 cases(20.0%) had leukocytosis, 1 case(3.3%) had neutrophilia, 10 cases(30.0%) had eosinophilia, 17 cases(56.7%) had increased ESR, and 18 cases(60.6%) had positive CRP. Positive cold agglutinin titers(>1 : 64) were 19 cases(63.3%), and positive mycoplasma antibody(M-ab) titers(>1 : 80) were 27 cases(93.3%). Mycoplasma antibody test was more valuable than cold agglutinin test for the diagnosis of Mycoplasmal pneumonia and there was no correlation between cold agglutinin titer and mycoplasma antibody titer. Mycoplasma-polymerase chain reaction(M-PCR) was done with 13 cases, 12 out of 13 cases(92.3%) were positive. M-PCR test was valuable to the diagnosis of Mycoplasmal pneumonia but it will be needed to further study for their clinical application. Among 30 cases, 5 cases(16.7%) had complications, 3 cases(10.0%) had skin rash, 1 case(3.3%) had pleural effusion, 1 case(3.3%) had arthralgia, but all complications were mild and recovered without residual sequelae. Conclusion : The occurrence of Mycoplasmal pneumonia under 3 year-old children was not rare from this study. Clinical characteristics of Mycoplasmal pneumonia under 3-year old were normal radiologic findings in many cases, low complication rate, mild clinical course, and tend to rapid recovery compared with general manifestations of Mycoplasmal infectionsin children and adolescence. There were likely to be missed patients with Mycoplasmal pneumonia which did not diagnose by conventional serologic tests that had low sensitivity and specificity. We have to pay attention to the Mycoplasmal infection of the young children with pneumonia during epidemic periods of Mycoplasmal infection.

  • PDF