• Title/Summary/Keyword: Skin Tests

Search Result 600, Processing Time 0.027 seconds

The Importance of Food Open Challenge Test in Atopic Dermatitis: The Comparison of Allergy History, Skin-Prick Test, and Specific IgE Detection

  • Noh, Geun-Woong;Ji, Eun-Jung;Park, Jung-Nan;Kim, Kyung-Hee;Do, Min-Hee;Lee, Eung-Kyung;Lee, Sang-Sun
    • Nutritional Sciences
    • /
    • v.2 no.2
    • /
    • pp.119-124
    • /
    • 1999
  • Food allergies play an important role in Atopic Dermatitis (AD). Dietary manipulation is essential in the management of AD. However, there has been a paucity of data reporting the prevalence of food allergies in AD patients in Korea. In this study, the Food Open Challenge Tests (FOCT) were conducted to investigate food allergies in AD patients. The skin-prick test and the detection of specific IgE, as well as allergy history of patient were used to detect food allergies in all AD patients. Elimination diet was conducted for two weeks prior to FOCTs. The prevalence of food allergies by FOCT is as follows: milk (67.3%); chicken (64.2%); pork (62.8%); eggs (61.0%); beef(55.4%) ; wheat (52.0%) and soybean (45.2%). Allergenic food items in Korean AD patients were different from people in other foreign countries. The seven major foods those tested positively by FOCTs were completely eliminated from the replaced diets for two weeks, and were subsequently reintroduced one at a time. Results from FOCTs were not comparable with allergy history or skin-prick tests or specific IgE detection. The sensitivity and specificity of skin-prick tests and specific IgE detection were lower than FOCTs. Allergy history, skin-prick tests, and specific IgE detection are useful for the identification of food allergen but its clinical significance differed according to food items. Therefore, we conclude that even though a 10-day delay was necessary after food challenge, FOCT is a useful and valid method to confirm food allergies and may be essential for the effective control of food allergies for treatment of AD.

  • PDF

Studies on the Correlation between SPF Index and Skin Irritation Index of Sunscreens (자외선 차단제의 SPF 지수와 피부자극지수와의 상관성 연구)

  • 김종원;서수경;최주영;박창원;서경원;김규봉;김광진;김재희;이선희
    • Biomolecules & Therapeutics
    • /
    • v.10 no.4
    • /
    • pp.246-252
    • /
    • 2002
  • In recent years, the safety of sunscreens has been challenged based on the reports of their adverse effect on users; dermatitis, allergic contact dermatitis and photo allergic contact dermatitis. The unscientific idea that higher SPF sunsreen is good for health mealeads many users to tend to prefer higher SPF sunscreen. In the toxicological aspect, the need to investigate the safety of sunscreens is steadily increasing. However, there were few studies on the correlation between sun protection factor (SPF) and the safety of sunscreens. The objective of this study was to assess whether there was a correlation between SPF and the safety of sunscreens. We measured in vitro SPF index using homosalate as a standard and examined the toxicity tests such as primary skin irritation tests, ocular irritation test and skin sensitization test. Homosalate (HS), octyl methoxycinnamate (OMC), octyl salicylate (OS), octocrylene (OC) as UVB organic filter and benzophenone-3 (BP3), butyl methoxy dibenzoil methane (BMDM) as UVA organic filter, and titanium dioxide (TD), zinc oxide (ZO) as inorganic filters were used. The skin irritation indexes in rabbits treated with HS, OMC, OS, BP3, and BMDM were significantly increased as SPF indices were increased. Neither ocular irritation in rabbits nor skin sensitization in guinea pigs were increased. It suggests that there might be a good correlation between SPF and the skin irritation indices of organic UV filters and skin irritation might be one of most sensitive index to assess the safety of sunscreens.

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.

Flexural and shear behaviour of profiled double skin composite elements

  • Anwar Hossain, K.M.;Wright, H.D.
    • Steel and Composite Structures
    • /
    • v.4 no.2
    • /
    • pp.113-132
    • /
    • 2004
  • Double skin composite element (DSCE) is a novel form of construction comprising two skins of profiled steel sheeting with an infill of concrete. DSCEs are thought to be applicable as shear or core walls in a building where they can resist in-plane loads. In this paper, the behaviour of DSCE subjected to combined bending and shear deformation is described. Small-scale model tests on DSCEs manufactured from micro-concrete and very thin sheeting were conducted to investigate the flexural and shear behaviour along with analytical analysis. The model tests provided information on the strength, stiffness, strain conditions and failure modes of DSCEs. Detailed development of analytical models for strength and stiffness and their performance validation by model tests are presented.

Clinical Study of MAST CLA and Sasang Constitution in Allergic Rhinitis Patients (알레르기비염 환자의 체질분포 및 특이적 IgE 측정법(MAST CLA)의 임상적 의의)

  • Kim, Chan-Jung;Kim, Hae-Jung;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.210-219
    • /
    • 2002
  • Background and Objectives The diagnosis of allergic rhinitis includes detailed clinical history, physical examination and the use of either in vivo or vitro tests for relevant allergens. Skin test has been used the most commonly. Recently MAST CLA is used for determination of serum spcecific IgE, This study attempted to find out the distribution of Sasang Constitution and to compare the MAST CLA with skin tests in allergic rhinitis patients. Methods Skin tests, MAST CLA and Sasang Constitution study were performed for 35 allergic rhinitis patients who visited Kyunghee Oriental Medical Center from Sept. 2001 to Nov. 2001. Results 1. The ratio between male and female was 1:1.5. the peak age was the thirties(42.9$\%$) 2. 45.7$\%$ of patients had family history of allergic diseases and allergic rhinitis was the most common. 3. 51.4$\%$ of patients lived in A.P.T. and in preference of cool and warm, 54.3$\%$ of patients prefered both of cool and warm. 4. Among 24 cases who were consulted to dept. of Sasang, 45.8$\%$ was Taeumin. 5. 65.7$\%$ of patients reacted positive to skin test and the common offending allergen was D. pteronyssinus(82.6$\%$). 6. 25.7$\%$ of patients reacted positive to MAST CLA and the common offending allergen was D. farinae(88.9$\%$). 7. Among 22 cases who was performed skin test and MAST CLA the sensivity and specificity of MAST CLA was 27.4$\%$ and 94.9$\%$. There was significant correlations between MAST CLA and skin test(p=0.005, r=0.574, 1, spearman correlation coefficienct).

  • PDF

Analysis of the Shaft Resistance of a Pile Embedded in Sand Responding to Ground Deformation by Model Tests of Simulated Ground Heaving (실내모형실험을 통한 지반 융기시 사질토 지반에 매설된 지반 변형 대응형 말뚝의 주면 마찰 저항 분석)

  • Shin, Sehee;Lee, Kicheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.1
    • /
    • pp.5-14
    • /
    • 2023
  • The pile driving process may lead to ground heaving, causing additional positive skin friction to act on the piles, compromising their stability. This study proposes a new pile foundation type that can reduce positive skin friction. This was investigated by designing and constructing a pile with a hydraulic cylinder which actively responds to ground deformation. The newly proposed pile design was compared against traditional piles in multiple model tests where ground heaving was simulated. In the tests, base load and total shaft resistance were measured during ground heaving and with expansion of the hydraulic cylinder. As a result of the tests, a very small amount of expansion of the hydraulic cylinder member completely reduced the positive skin friction and increased the base load. Excessive expansion of the hydraulic cylinder, however, generates negative skin friction beyond the zero skin friction state. Therefore, it is necessary to estimate the appropriate level of hydraulic cylinder expansion, taking into account the amount of ground heaving and the allowable displacement of the pile.

Design, Analysis and Test of Smart Skin structure with a round shape antenna (원형 안테나 구조를 갖는 스마트 스킨 구조 설계, 해석 및 시험)

  • Joe, June-Sung;Goo, Nam-Seo;Park, Hoon-Cheol;Yoon, Kwang-Joon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.46-50
    • /
    • 2005
  • Smart skin, a multi-layer structure of composed of a round shape antenna, was designed and fabricated. Tests and analyses was conducted to study its behavior under compressive loads. It was confirmed that the designed smart skin failed due to premature buckling before compression failure. Numerical prediction of structural behavior of smart skin by MSC.NASTRAN agreed well with experimental data.

  • PDF

Effects of Foot Mats on Levels of Fatigue, Discomfort, Lower Extremity Edema and Skin Temperature in Scrub Nurses (발매트 적용이 수술실 소독간호사의 피로도, 불편감, 하지 부종 및 피부온도에 미치는 영향)

  • Hwang, Soon Hee;Jun, Sang-Eun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.21 no.3
    • /
    • pp.309-318
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the effects of foot mats on reducing levels of fatigue, discomfort, lower extremity edema and skin temperature in scrub nurses during surgery. Methods: This study employed one group repeated measures design in which 16 scrub nurses (ages 22-38) stood on steel footstools (SF) during scrub as the conventional test and stood on SF with foot mats as the experimental test. Levels of fatigue, discomfort, lower extremity edema and skin temperature were measured before the first surgical hand scrub and right after the first surgery of the day for 3 consecutive days in both tests. Results: The changes in levels of fatigue and discomfort were significantly different between tests (p<.001~.033). Edema, determined by the differences in circumferences of the ankles and calves before and after the surgery was also significantly different between groups (p=.001~.011). However, the change in skin temperature on the foot tops of both feet was not different between tests (p=.351~.467). Conclusion: The results of this study show that using foot mats on top of the steel footstool is effective in reducing the levels of fatigue, discomfort and lower extremity edema in scrub nurses during surgery.

SAFETY EVALUATION OF SUNSCREENS (I) ; CORRELATION BETWEEN SUN PROTECTION FACTOR AND SKIN IRRITATION

  • Suh, Soo-Kyung;Kim, Jong-Won;Park, Ju-Young;Seo, Kyung-Won;Park, Chang-Won;Kim, Kyu-Bong;Kim, Kwang-Jin;Kim, Jong-Min;Lee, Sun-Hee
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05a
    • /
    • pp.138-138
    • /
    • 2002
  • In recent years, the safety of sunscreens has been challenged based on the reports of its adverse effect on users; dermatitis, allergic contact dermatitis, photoallergic contact dermatitis. To investigate a correlation between sun protection factor (SPF) and the safety of sunscreens, we measured in vitro SPF index using homosalate as a standard and examined the toxicity tests on cosmetics; primary and cumulative skin irritation tests, ocular irritation test, and skin sensitization test.(omitted)

  • PDF

Eye Irritation, Skin Irritation and Skin Sensitization tests for Aloewhite in Animals

  • Kim, Hyung-Sik;Kwack, Seung-Jun;Kim, Kyu-Bong;Lee, Seung-Ki;Park, Hyun-Sun;Hong, Che-Young;Ahn, Mi-Young;Jo, Tea-Hyung;Oh, Sun-Tack
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.250-250
    • /
    • 1996
  • Eye irritation, primary skin irritation and skin sensitization tests for Aloewhite were tested in New Zealand White rabbits and Hartley guinea pig. In primary skin irritation test of male New Zealand White rabbits, body weights were not significantly changed and primary Irritation Index(PII) was 0.47, indicating Aloewhite as mildly irritating material, In ocular irritation test, any injury on iris, conjunctival membrane, and cornea in New Zealand White rabbits was not observed. No injuries of the ocular mucous membrane were also recorded. Skin sensitization was tested in guinea Peg after intradermal and epicutaneous induction and graded I with zero % sensitization rate. These results indicate that Aloewhite was not considered to be irritant in test organs of animals.

  • PDF