• Title/Summary/Keyword: Skin Pass

Search Result 63, Processing Time 0.037 seconds

A Study on the Influence of Process Parameters on Residual Stress and Reducing Residual Stress for Drawn Wire Using FE-Analysis (유한요소 해석에 의한 공정변수가 인발 선재의 잔류응력에 미치는 영향평가 및 완화에 관한 연구)

  • Lee S.G.;Hwang W.H.;Kim B.M.;Bae C.M.;Lee C.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.834-837
    • /
    • 2005
  • This study presents a study on the influence of process parameters(semi-die angle, die reduction, friction condition, and bearing length) in drawn wire on residual stresses were investigated using FE-analysis. In this study, semi-die angle and die reduction have a significant effect on the residual stresses at the surface of drawn wire. In the previous study, in order to reduce the residual stresses, several methods were suggested: addition of axial tension, application of skin pass, straightening in multi-roll straightener etc. In this study, it can be known that the concurrent application of skin pass with low die reduction and low semi-die angle at the final stage of drawing operation reduces dramatically the both axial and hoop residual stresses after drawing.

  • PDF

Shape Decision of the Stainless Steel at the Skin Pass Mill (스테인리스 냉연공정에서 강판의 형상판정)

  • Hur, Yone-Gi;Choi, Young-Kiu
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1047-1048
    • /
    • 2008
  • The objective of this paper is to build a decision method of the shape quality for the stainless steel and ensure reducibility of working-load for next rolling process. The criterion of the shape quality is derived from the customer needs, and Automatic Shape Decision System is implemented in SPM (Skin Pass Mill). The methods of shape decision are based on curve fitting and frequency analysis and so on. The Field Test with concerned customers is successful. The performance of right decision is 99% and the claims from the customer have been largely reduced.

  • PDF

Development of set-up model for elongation control in steel skin pass mill (강판의 연신율제어를 위한 Set-Up 모델 개발)

  • 이원호;이규택;류율리
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.317-317
    • /
    • 2000
  • The mathematical set-up model was developed to reduce the mechanical property deviation in annealed and slightly rolled steel strip. The mechanical peculiarities of temper rolling process, such as high friction value and non-circular contact arc, Low reduction and non-negligible entry and exit elastic zones as well as central restricted deformation zone are all taken into account. The deformation of work rolls is calculated with the influence function method and arbitrary contact arc shape is permitted. The strip deformation is modeled by slab method and the entry and exit elastic deformation zones are included. The restricted deformation Bone near the neutral point is also considered. It was revealed that the new model has better accuracy than present regression model by statistical analysis with actual mill rolling data.

  • PDF

Design of myoelectrical sensor for myoelectric hand prosthesis (전동의수용 근전위 센서 설계)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF

Correlation Between Skin Roughness and Dermal Density of Skin Wrinkle Evaluation (피부 주름 평가에 있어서의 피부 거칠기와 진피 치밀도의 상관성 연구)

  • Lee, Hee-Kyung;Back, Ji-Hwoon;Koh, Jae-Sook;Park, Deok-Hoon;Lee, Jong-Sung;Jung, Eun-Sun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.2 s.57
    • /
    • pp.123-127
    • /
    • 2006
  • In this study, we evaluated the crow's fret of 95 Korean female by using mechanical assessments; Skin-Visiometer SV 600 and Dermascan C. Transparency profilometry (Skin Visiometer) were using a very thin skin print which allowed parallel light to pass through and was analysed immediately after production. High-frequency (20 MHz) ultrasonography (Dermascan C) enabled non-invasive evaluation in skin thickness and echodensity. We found a correlation between skin roughness and dermal density. Particularly, we showed a significant correlation between skin roughness (R2) and dermal thickness. Also, we demostrated a significant negative correlation between dermal density and dermal thickness (p < 0.05). Therefore, the ultrasonography system might be considered a very useful method in wrinkle evaluation with the transparency profilometry. Further study will be required.

Enhancement of Transdermal Drug Delivery Using Ultrasound (초음파를 이용한 경피약물수송의 촉진)

  • Park, Seung-Kyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.719-726
    • /
    • 2001
  • Transdermal drug delivery offers various advantages over conventional drug delivery systems, such as avoidance gastrointestinal degradation and hepatic first-pass effect. encourages patient compliance. and possible sustained release of drugs. However, transdermal transport of drugs is low permeability of the stratum corneum, the superficial layer of the skin. Many physicochemical and biological factors influencing transdermal transport is described together with the corresponding experimental and clinical results. Phonophoresis is medical treatment with drugs introduced into the skin by ultrasound energy. Enhanced drug penetration is through to result from the biophysical alterations of skin structure by ultrasound waves. The frequency used for phonophoresis is usually from 20 kHz to 15MHz. Phonophoresis can be categorized in to three ranges: low-frequency range(below 1 MHz). therapeutic frequency range(1 to 3MHz), and high-frequency range(above 3 MHz). The depth of penetration of ultrasound into skin is inversely proportional to the frequency. Cavitation may cause mechanical stress. temperature elevation, or enhanced chemical reactivity causing drug transport. One theory is that ultrasound affects the permeation of the stratum corneum lipid structure as the limiting step in permeating through the skin. The range of indications for phonophoresis is wide. Aspecific classification of the range of indications is obtained by classification of pathological conditions. The continuous research is needed for many interesting issucs of phonophoretic transdermal delivory in new future.

  • PDF

The Study of Age-related Skin Pigmentation Changes in Korean Female (한국 여성의 연령에 따른 색소 침착 변화 연구)

  • Myeongryeol Lee;Yuchul Jung;Byung-Fhy Suh;Eunjoo Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.2
    • /
    • pp.177-182
    • /
    • 2023
  • Since facial skin pigmentation is one of the visual characteristics of skin aging, it is important to evaluate skin pigmentation in the cosmetics and aesthetic fields. Several groups have investigated and developed the image analysis methods for skin pigmentation and some of the groups reported the age-related changes of the number and size of facial pigmented spots. However, they didn't show the changes of the number and size of pigment spots by defined size, and there is no report for Korean female regarding pigmentation. A total of 194 Korean females aged 20 ~ 79 (48.97 ± 17.11 years) were analyzed for the number, size, and intensity of pigmented spots using various filters such as large high-pass filter and median filter in their digital facial images. There were significant correlations between age and total pigmented spot number (No.), size, and intensity (I) (pearson's correlation coefficient r = 0.688, r = 0.645, r = -0.563), and significant correlations were also observed between the number and intensity of pigmented spots of different sizes. According to the ANOVA results, there were significant differences in the percentage of spot size of 2 ~ 4 mm2 and > 20 mm2 between 20's and 70's. In other words, with aging, pigmentation increases in the facial skin, and the large increase in pigmentation is particularly noticeable in Korean women.

Physiological Responses and Subjective Sensation of Human Body Wearing OnMapsi in Heating Environment (난방환경에서 온(溫)맵시 착용에 따른 생리적 반응 및 주관적 감각)

  • Na, Young-Joo;Lee, Ji-Yun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.1
    • /
    • pp.1-12
    • /
    • 2011
  • This study tests the performance of the recommended winter dress OnMapsi for an office worker through the analysis of skin temperature changes according to the heating environment. We tested and compared the effects of with/without undergarments for 4 male subjects in an artificial-climate chamber with two air temperatures of $19^{\circ}C$ and $22^{\circ}C$, $50{\pm}10%$ R.H. During the 60 minute experiment that simulated office work, the subjective feelings (that included thermal, humidity and comfort sensation, and skin temperature) were measured at equal intervals. The results show that the forehead and chest skin temperatures were not affected by air temperature or clothing type, while the hand and foot skin temperatures were affected at $0.3-0.9^{\circ}C$ depending on clothing type and $1.9-2.2^{\circ}C$ depending on air temperature. The mean skin temperature was decreased by the experimental time pass more with regular formal wear than with OnMapsi. The second experiment located the ambient temperature in which subjects wearing OnMapsi show equal skin temperaturesto those without undergarments at $22^{\circ}C$. Therefore it is possible to decrease heating temperatures to $18-21^{\circ}C$ in the office for winter OnMapsi wear that produces a skin temperature and thermal sensation that is the same as those at $22^{\circ}C$.