• Title/Summary/Keyword: Skin Mesh

Search Result 51, Processing Time 0.034 seconds

Use of the Full-thickness Free Skin Mesh Graft for Reconstruction of Wound in a Dog (개의 피부손상에 대한 전층망상식피술 증례)

  • Kim, Joo-Ho;Lee, Jong-Il;Lee, Hae-Beom;Heo, Su-Young;So, Kyoung-Min;Ko, Jae-Jin;Chon, Seung-Ki;Lee, Cheol-Ho;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.280-283
    • /
    • 2007
  • A 6-year-old male dog was referred to Animal Medical Center, Chonbuk National University with large distal extremity abrasion wound to the hind limb by automobile accident. The wound was reconstructed with an autogenous, full-thickness skin mesh graft. The graft was harvested from the ventrolateral abdominal wall and transplanted to the wound. The skin mesh graft survived successfully without any noticeable complications. Successful grafting requires asepsis, an adequately prepared recipient bed through the surgical debridement and lavage, proper harvesting and preparation of the graft. Full-thickness skin mesh graft has lesser skin contraction which prevents formation of scar. Meshing the graft provides more graft flexibility over uneven, convex and concave surfaces and allows adequate drainage. The full-thickness skin mesh graft can be successfully used for the treatment of large distal skin wounds in dogs.

Application of Grid-based Approach for Auto Mesh Generation of Vacuum Chamber (자동 요소망 생성을 위한 격자구성기법 적용)

  • Lee J.S.;Park Y.J.;Chang Y.S.;Choi J.B.;Kim Y.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.844-847
    • /
    • 2005
  • A seamless analysis of complex geometry is one of greatly interesting topic. However, there are still gaps between the industrial applications and fundamental academic studies owing to time consuming modeling process. To resolve this problem, an auto mesh generation program based on grid-based approach has been developed for IT-product in the present study. At first, base mesh and skin mesh are generated using the information of entities which extracted from IGES file. Secondly the provisional core mesh with rugged boundary geometry is constructed by superimposing the skin mesh as well as the base mesh generated from the CAD model. Finally, the positions of boundary nodes are adjusted to make a qualified mesh by adapting node modification and smoothing techniques. Also, for the sake of verification of mesh quality, the hexahedral auto mesh constructed by the program is compared with the corresponding tetrahedral free mesh and hexahedral mapped mesh through static finite element analyses. Thereby, it is anticipated that the grid-based approach can be used as a promising pre-processor for integrity evaluation of various IT-products.

  • PDF

Flexural Behavior of Highly Ductile Cement Composites Mimicking Boundary Conditions of Shellfish Skin Layer (패류 껍질층의 경계면을 모방한 고연성 시멘트 복합재료의 휨 거동)

  • Kwon, Ki-Seong;Chun, Jae-Yeong;Bang, Jin-Wook;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.108-115
    • /
    • 2020
  • In this study, the flexural performance of Highly Ductile Cement Composites(HDCC) mimicking boundary conditions of shellfish skin layer was evaluated. To improve ductility by mimicking the boundary skin layer structure of shellfish, the method of stratification by charging between precast panels using HDCC and the method of distributing PE-mesh to the interface surface were applied. Evaluation of flexural performance of layered cement composite materials mimicking boundary conditions of shellfish skin layer resulted in increased ductility of all test specimens applied with stratified cross-section compared to typical bending test specimens. The layered method by inserting PE-mesh showed excellent ductility. This is most likely because the inserted PE-mesh made an interface for separating the layers while the HDCC pillars in the PE-mesh gave adhesion between layers.

Comparison and validation of Brass mesh bolus using tissue equivalent bolus in the breast cancer radiotherapy (유방암 방사선치료시 조직등가보상체와의 비교를 통한 Brass mesh bolus의 유용성 평가)

  • Bong, Juyeon;Kim, Kyungtae;jeon, Mijin;Ha, Jinsook;Shin, Dongbong;Kim, Seijoon;Kim, Jongdae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2017
  • Purpose: In breast cancer radiotherapy, brass mesh bolus has been recently studied to overcome disadvantage of conventional bolus. The purpose of this study is to investigate the stability of first introduced the brass mesh in the country, and evaluate the skin surface dose of that. Materials and Methods: The measurement of skin surface dose was evaluated to verify similar thickness of the Brass mesh bolus that compared conformal tissue equivalent bolus with 5 mm thickness. We used 6 MV photons on an ELEKTA VERSA linear accelerator and optically stimulated luminescent dosimeter (OSLD). In addition, two opposed beam using IMRT phantom was applied to comparative study of brass mesh bolus between tissue equivalent bolus. Results: The results showed that similar thickness of the Brass mesh bolus was 3 mm compared with 5 mm tissue equivalent bolus by measuring the skin surface dose of solid phantom. The surface dose for IMRT thorax phantom using 3 mm brass mesh bolus was about 1.069 times greater than that using tissue equivalent bolus. Conclusion: In this study, we found that the brass mesh bolus improved better reduction of skin sparing effect and dose uniformity than tissue equivalent bolus. However evaluation for various clinic cases should be investigated.

  • PDF

Reconstructing individual hand models from motion capture data

  • Endo, Yui;Tada, Mitsunori;Mochimaru, Masaaki
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we propose a new method of reconstructing the hand models for individuals, which include the link structure models, the homologous skin surface models and the homologous tetrahedral mesh models in a reference posture. As for the link structure model, the local coordinate system related to each link consists of the joint rotation center and the axes of joint rotation, which can be estimated based on the trajectories of optimal markers on the relative skin surface region of the subject obtained from the motion capture system. The skin surface model is defined as a three-dimensional triangular mesh, obtained by deforming a template mesh so as to fit the landmark vertices to the relative marker positions obtained motion capture system. In this process, anatomical dimensions for the subject, manually measured by a caliper, are also used as the deformation constraints.

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

Implications of using a 50-μm-thick skin target layer in skin dose coefficient calculation for photons, protons, and helium ions

  • Yeom, Yeon Soo;Nguyen, Thang Tat;Choi, Chansoo;Han, Min Cheol;Lee, Hanjin;Han, Haegin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1495-1504
    • /
    • 2017
  • In a previous study, a set of polygon-mesh (PM)-based skin models including a $50-{\mu}m-thick$ radiosensitive target layer were constructed and used to calculate skin dose coefficients (DCs) for idealized external beams of electrons. The results showed that the calculated skin DCs were significantly different from the International Commission on Radiological Protection (ICRP) Publication 116 skin DCs calculated using voxel-type ICRP reference phantoms that do not include the thin target layer. The difference was as large as 7,700 times for electron energies less than 1 MeV, which raises a significant issue that should be addressed subsequently. In the present study, therefore, as an extension of the initial, previous study, skin DCs for three other particles (photons, protons, and helium ions) were calculated by using the PM-based skin models and the calculated values were compared with the ICRP-116 skin DCs. The analysis of our results showed that for the photon exposures, the calculated values were generally in good agreement with the ICRP-116 values. For the charged particles, by contrast, there was a significant difference between the PM-model-calculated skin DCs and the ICRP-116 values. Specifically, the ICRP-116 skin DCs were smaller than those calculated by the PM models-which is to say that they were under-estimated-by up to ~16 times for both protons and helium ions. These differences in skin dose also significantly affected the calculation of the effective dose (E) values, which is reasonable, considering that the skin dose is the major factor determining effective dose calculation for charged particles. The results of the current study generally show that the ICRP-116 DCs for skin dose and effective dose are not reliable for charged particles.

Pencil Curve Computation for Clean-up Machining (잔삭 가공을 위한 펜슬커브 생성)

  • Park T.J.;Park S.C.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2006
  • This paper presents a procedure to compute pencil curves from a triangular mesh which is offset with the radius of a given ball-end mill. An offset triangular mesh has numerous self-intersections caused by an abundance of invalid triangles, which do not contribute to the valid CL-surface. Conceptually, we can obtain valid pencil curves by combining all intersections tying on the outer skin of the offset triangular mesh, i.e., the valid CL-surface. The underlying concept of the proposed algorithm is that visible intersections are always valid for pencil curves, because visible intersections lie on the outer skin of the offset model. To obtain the visibility of intersections efficiently, the proposed algorithm uses a graphics board, which performs hidden surface removal on up to a million polygons per second.

Sensor Circuit Design using Carbon Nanotube FET for Artificial Skin

  • Kim, Yeon-Bo;Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.3
    • /
    • pp.41-48
    • /
    • 2014
  • This paper proposes a new sensor circuit using a 32 nm carbon nanotube FET (CNFET) technology for artificial skin. For future robotic and prosthetic applications, it is essential to develop a robust and low power artificial skin for detecting the environment through touch. Therefore, a sensor circuit for the artificial skin also has to be developed to detect the sensor signals and convert them into digital bits. The artificial skin sensor is based on a mesh of sensors consisting of a nxn matrix using CNFET, and the sensor outputs are connected to a current monitoring circuit proposed as the sensor circuit. The proposed sensor provides pressure measurements and shape information about pressure distribution.

TISSUE-ENGINEERED RECONSTITUTION OF ORAL MUCOSA USING POLYDIOXANONE MESH (Polydioxanone mesh를 이용한 구강점막의 조직 공학적 재건)

  • Moon, Seon-Jae;Joo, So-Yeon;Kim, Jin;Kim, Hak-Yong;Park, Jung-Keug;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.249-256
    • /
    • 2003
  • The lack of sufficient oral mucosa available for intra-oral reconstruction has been dealt with by the use of skin or oral mucosa grafts harvested from donor sites but grafts requires more than one surgical procedures and could cause donor site morbidity. Many investigators have attempted to increase available soft tissue by tissue engineered skin or oral mucosa replacements for clinical applications. But, reconstructed mucosa by several methods have low physical properties such as rolling and contraction. The aims of this study were to develope an in vitro experimental model that maintains an epithelial-mesenchymal interaction by organotypic raft culture, and to characterize biologic properties of three-dimensionally cultured oral mucosa embedded with Polydioxanone mesh by histological and immunohistochemical analysis. The results were as follows; 1. Oral mucosa reconstructed by three-dimensional organotypic culture revealed similar morphologic characteristics to equvalent normal oral mucosa in the point that they show stratification and differentiation. 2. The expression of cytokeratin 10/13 and involucrin in the cultured tissue showed the same pattern with normal oral mucosa suggesting that organotypic co-culture condition is able to induce cellular differentiation. 3. After insertion of polydioxanone mesh, increased tensile strength were observed. These results suggest that three-dimensional organotypic co-culture of the oral mucosa cell lines with the dermal equvalent consisting type I collagen and fibroblasts reproduce the morphologic and immunohistochemical characteristics similar to those in vivo condition. And increased physical properties by use of polydioxanone mesh will helpful for clinical applications.