• Title/Summary/Keyword: Skin Detection

Search Result 573, Processing Time 0.205 seconds

T-SPOT.TB for Detection of Tuberculosis Infection among Hematological Malignancy Patients and Hematopoietic Stem Cell Transplant Recipients

  • Qin, Li-Li;Wang, Qin-Rong;Wang, Qian;Yao, Hong;Wen, Li-Jun;Wu, Li-Li;Ping, Na-Na;Xie, Jun-Dan;Chen, Mei-Yu;Chen, Su-Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7415-7419
    • /
    • 2013
  • The diagnosis of latent Mycobacterium tuberculosis infection (LTBI) is recommended in hematological malignancy patients and before hematopoietic stem cell transplantation (Guidelines for the prevention and management of infectious complications of solid organ transplantation, 2004). Compared to traditional methods such as tuberculin skin test (TST), T-SPOT.TB has been shown to be more specific. In the present study we enrolled 536 patients for whom T-SPOT.TB was performed, among which 295 patients also received the TST test. The agreement (79%) between T-SPOT.TB and TST was poor (x=0.274, P<0.001). The patients with positive T-SPOT.TB results numbered 62 (11.6%), in which only 20 (48.8%) of the 41 receiving the TST test had positive results. A majority of the patients with T-SPOT.TB positive results had some other evidence ofTB, such as TB history, clinical symptoms and an abnormal chest CT scan. Active TB was found in 9 patients, in which 2 had negative TST results. We followed up the patients and no one developed active TB. Our study suggested that the T-SPOT.TB may be more useful for screening LTBI and active TB in hematological malignancy patients and hematopoietic stem cell transplant recipients than the TST test.

Clinical Significance of Interferon $\gamma$ Release Assay for Diagnosis of Tuberculosis in Children (소아 결핵 진단에 있어서 결핵 특이항원자극 인터페론 감마 측정검사의 임상적 의의)

  • Lee, Hee Woo;Park, Hwa Young;Ahn, Young Min;Sohn, Keun Chan
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.137-147
    • /
    • 2010
  • Purpose : The purpose of this study is to evaluate the usefulness and limitation of QuantiFERON-TB Gold (QTB) for diagnosis of latent tuberculosis in children. Methods : The medical records of 112 children who were tested by tuberculin skin test (TST) and QTB for detection of latent tuberculosis (TB) in Eulji General Hospital during the period from January 2007 to June 2009 were retrospectively reviewed. Results : Of the 112 participants, the clinical TB group included 15 (13.4%), the contact group included 43 (38.4%), and the non-contact group included 54 (48.2%). Positive rates of TST and QTB were 100% and 80% in the clinical TB group, 64% and 14% in the close contact group, 27% and 0% in the casual contact group, and 52% and 2% in the non-contact group, respectively. Sensitivity of QTB was 80.0% and specificity was 92.6%. Agreement between QTB and TST was poor ($\kappa$=0.209). We also confirmed that the positive rate of QTB increased as the age of the patient increased (P=0.011). A QTB indeterminate result was observed in 11 (9.8%) subjects. QTB was retested in 15 subjects. In 5 of the 6 subjects who had positive results initially, positive results persisted for a median 2.2 months after termination of treatment. Conclusion : Although QTB was associated with several problems, including low sensitivity and a high rate of indeterminate results, it had clinical importance due to its high specificity. We found good correlation with regard to exposure and QTB positivity, including that of young children under 5 years of age. However, clinical application of interferon-$\gamma$ releasing assay for young children for diagnosis of active and latent tuberculosis will require additional prospective studies.

Simultaneous Analysis of Antimicrobial Three Straight Chain 1,2-alkanediols in Cosmetics by Gas Chromatography (가스크로마토그래피를 이용한 화장품 중 항균작용의 3종의 직쇄상 1,2-알칸디올류의 동시분석)

  • Lee, Hoo Seob;Lee, Sang Hun;Kim, Eun Juk;Chung, Cheol Hee;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • Preservatives such as paraben, phenoxyethanol, and chlorphene are commonly used in cosmetics thanks to cheap price and good antiseptic effect. Recently, consumers' concerns about their possible toxicity and skin irritation forced them to be replaced with straight 1,2-alkanediols. However, as the alkanediols may also irritate skin, limited amount of them should be used in cosmetics. Three 1,2-alkanediols including 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol in cosmetics were analyzed simultaneously by gas chromatogrphy with flame ionization detector. As a result of method validation, the specificity was confirmed by the calibration curves of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol showing good linearity correlation coefficient of above 0.999 over the concentration range of $100{\sim}1,200{\mu}g/g$. The limit of detection (LOD) and quantification (LOQ) of 1,2-pentanediol, 1,2-hexanediol, and 1,2-octanediol were 31, 40, and $19{\mu}g/g$ and 98, 108, and $57{\mu}g/g$, respectively. The precision (Repeatability) of the amount in cosmetics showed less than 2.0%. Relative Standard Deviation (% RSD) and the Accuracy (% recovery) of the amount in cosmetics showed 99.3 ~ 103.3, 99.4 ~ 106.7, 97.5 ~ 107.3% respectively. As a result, simultaneous analysis of antimicrobial three 1,2-alkanediols in cosmetics were possible. This method can be utilized in accurate quantitative analysis of 1,2-alkanediols in cosmetics.

Display of Irradiation Location of Ultrasonic Beauty Device Using AR Scheme (증강현실 기법을 이용한 초음파 미용기의 조사 위치 표시)

  • Kang, Moon-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.25-31
    • /
    • 2020
  • In this study, for the safe use of a portable ultrasonic skin-beauty device, an android app was developed to show the irradiation locations of focused ultrasound to a user through augmented reality (AR) and enable stable self-surgery. The utility of the app was assessed through testing. While the user is making a facial treatment with the beauty device, the user's face and the ultrasonic irradiation location on the face are detected in real-time with a smart-phone camera. The irradiation location is then indicated on the face image and shown to the user so that excessive ultrasound is not irradiated to the same area during treatment. To this end, ML-Kit is used to detect the user's face landmarks in real-time, and they are compared with a reference face model to estimate the pose of the face, such as rotation and movement. After mounting a LED on the ultrasonic irradiation part of the device and operating the LED during irradiation, the LED light was searched to find the position of the ultrasonic irradiation on the smart-phone screen, and the irradiation position was registered and displayed on the face image based on the estimated face pose. Each task performed in the app was implemented through the thread and the timer, and all tasks were executed within 75 ms. The test results showed that the time taken to register and display 120 ultrasound irradiation positions was less than 25ms, and the display accuracy was within 20mm when the face did not rotate significantly.

The Topical Absorption of Ketoprofen from Gels and Plaster in Human Volunteers (케토프로펜 겔제와 플라스터제의 피부 흡수 비교)

  • Gang, Won-Gu;Lee, Chang-Hyeon;U, Jong-Su;Gwon, Gwang-Il
    • YAKHAK HOEJI
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • This study was designed to compare the absorption fraction and extent of ketoprofen gels and a matrix typed ketoprofen plaster patch. 3g (90mg as ketoprofen) of the two gels whi ch has oleohydrogel or hydrogel as a base, respectively, and 3 pieces of plaster patches (90mg as ketoprofen) were, applied in the area of 210$cm^2$ on forearm in 12 volunteers by cross over design. Blood samples were collected serially up to 24 hours and the plasma concentrations of ketoprofen were analyzed by HPLC using flurbiprofen as an internal standard. The detection limit of the assay was 1ng/ml of ketoprofen in plasma. The pharmacokinetic parameters (e.g. $AUC_{24hr}$, $AUMC_{24hr}$, MRT, Fraction Absorbed) were calculated from the plasma concentrations time data of each volunteer. The oleo-hydrogel showed significantly higher absorption fraction and extent of ketoprofen than the current hydrogel. The mean plasma concentrations of the oleo-hydrogel were increased to 98.46${\pm}$23.15ng/ml by 6 hour after application, and increased futher to 100.61${\pm}$18.65ng/ml at 24 hour. On the other hand, those of the hydrogel were increased 17.61${\pm}$18.65ng/ml at 5 hour to 34.68${\pm}$9.65ng/ml at 24 hour gradually. Therefore the plasma concentrations of oleo-hydrogel at each measured time were 3~7 times greater than those of the hydrogel with statistical significance. The $AUC_{24hr}$ (1797.26${\pm}$52.09ng.h/ml) of the oleo-hydrogel was 3.5 times greater (P<0.05) than that (516.17${\pm}$104.52ng.h/ml) of the hydrogel. The plaster patches showed higher bioavailability ($AUC_{24hr}$ 2877.37${\pm}$578.27ng.h/ml) than the olea-hydrogel ($AUC_{24hr}$ 1797.26${\pm}$52.09ng.h/ml) without statistical significance. But the absorption fraction of the oleo-hydrogel was rather higher than that of the plaster patches during the first 6 hours after administration. These results suggest that newly developed ketoprofen gel which is used oleo-hydrogel as a base would show excellent skin permeation on topical application for the corresponding clinical indications and could be absorbed as well as plaster patches.

  • PDF

Efficient Intermediate Joint Estimation using the UKF based on the Numerical Inverse Kinematics (수치적인 역운동학 기반 UKF를 이용한 효율적인 중간 관절 추정)

  • Seo, Yung-Ho;Lee, Jun-Sung;Lee, Chil-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.39-47
    • /
    • 2010
  • A research of image-based articulated pose estimation has some problems such as detection of human feature, precise pose estimation, and real-time performance. In particular, various methods are currently presented for recovering many joints of human body. We propose the novel numerical inverse kinematics improved with the UKF(unscented Kalman filter) in order to estimate the human pose in real-time. An existing numerical inverse kinematics is required many iterations for solving the optimal estimation and has some problems such as the singularity of jacobian matrix and a local minima. To solve these problems, we combine the UKF as a tool for optimal state estimation with the numerical inverse kinematics. Combining the solution of the numerical inverse kinematics with the sampling based UKF provides the stability and rapid convergence to optimal estimate. In order to estimate the human pose, we extract the interesting human body using both background subtraction and skin color detection algorithm. We localize its 3D position with the camera geometry. Next, through we use the UKF based numerical inverse kinematics, we generate the intermediate joints that are not detect from the images. Proposed method complements the defect of numerical inverse kinematics such as a computational complexity and an accuracy of estimation.

Verification of Estrogen Like Activities of Herbal Medicines Using an In Vitro Detection System (In vitro 검출 시스템을 이용한 한약재 추출물들의 에스트로겐 유사활성 검증)

  • Park, Seong Hwan;Jeon, Myong Je;Jang, Min Kyung;Lee, Sol Jee;Kim, Bo Kyung;Jeon, Myeong Jeong;Kim, Seo Yeon;Kim, Mihyang;Lee, Dong Geun;Lee, Tae Ho;Nam, Jae Sub;Hur, Ji Won;Lee, Sang Hyeon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.752-758
    • /
    • 2013
  • Estrogen like activities were evaluated using ethanol and hot water extracts of herbal medicines by using an in vitro detection system. Bokryung (Poria cocos), Sanyak (root of Dioscorea batatas) and Mokdanpi (root skin of Paeonia suffruticosa) represented statistically significant estrogen-like activities (p<0.001), while Omija (fruit of Schizandra chinensis), Taeksa (root of Alisma canaliculatum A. BR.), Jihwang (root of Rhemannia glutinosa), and Sansuyu (fruit of Cornus officinalis) did not. Estrogen-like activities of Bokryung hot water extract (500 ${\mu}g/ml$) and ethanol extract (50 ${\mu}g/ml$) were almost same as that of a C M $17{\beta}$-estradiol. Furthermore, estrogen-like activities of ethanol extracts (500 ${\mu}g/ml$) of Bokryung and Mokdanpi were stronger than that of $10^{-7}$ M $17{\beta}$-estradiol. These results suggest that Bokryung, Sanyak and Mokdanpi show estrogen-like activities. Especially, Sanyak and Mokdanpi represented promotive effect on the proliferation of MC3T3-E1 osteoblastic cells. Bokryung, Sanyak and Mokdanpi also exhibited superior inhibitory effect on the viability of RAW 264.7 cells. In conclusion, these three herbal medicines might be interpreted as candidates for the further study or development of functional foods or medicine to prevent or avoid postmenopausal symptoms of women.

Hand Gesture Recognition Algorithm Robust to Complex Image (복잡한 영상에 강인한 손동작 인식 방법)

  • Park, Sang-Yun;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1000-1015
    • /
    • 2010
  • In this paper, we propose a novel algorithm for hand gesture recognition. The hand detection method is based on human skin color, and we use the boundary energy information to locate the hand region accurately, then the moment method will be employed to locate the hand palm center. Hand gesture recognition can be separated into 2 step: firstly, the hand posture recognition: we employ the parallel NNs to deal with problem of hand posture recognition, pattern of a hand posture can be extracted by utilize the fitting ellipses method, which separates the detected hand region by 12 ellipses and calculates the white pixels rate in ellipse line. the pattern will be input to the NNs with 12 input nodes, the NNs contains 4 output nodes, each output node out a value within 0~1, the posture is then represented by composed of the 4 output codes. Secondly, the hand gesture tracking and recognition: we employed the Kalman filter to predict the position information of gesture to create the position sequence, distance relationship between positions will be used to confirm the gesture. The simulation have been performed on Windows XP to evaluate the efficiency of the algorithm, for recognizing the hand posture, we used 300 training images to train the recognizing machine and used 200 images to test the machine, the correct number is up to 194. And for testing the hand tracking recognition part, we make 1200 times gesture (each gesture 400 times), the total correct number is 1002 times. These results shows that the proposed gesture recognition algorithm can achieve an endurable job for detecting the hand and its' gesture.

Face Tracking Method based on Neural Oscillatory Network Using Color Information (컬러 정보를 이용한 신경 진동망 기반 얼굴추적 방법)

  • Hwang, Yong-Won;Oh, Sang-Rok;You, Bum-Jae;Lee, Ji-Yong;Park, Mig-Non;Jeong, Mun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.40-46
    • /
    • 2011
  • This paper proposes a real-time face detection and tracking system that uses neural oscillators which can be applied to access regulation system or control systems of user authentication as well as a new algorithm. We study a way to track faces using the neural oscillatory network which imitates the artificial neural net of information handing ability of human and animals, and biological movement characteristic of a singular neuron. The system that is suggested in this paper can broadly be broken into two stages of process. The first stage is the process of face extraction, which involves the acquisition of real-time RGB24bit color video delivering with the use of a cheap webcam. LEGION(Locally Excitatory Globally Inhibitory)algorithm is suggested as the face extraction method to be preceded for face tracking. The second stage is a method for face tracking by discovering the leader neuron that has the greatest connection strength amongst neighbor neuron of extracted face area. Along with the suggested method, the necessary element of face track such as stability as well as scale problem can be resolved.

Simultaneous Determination of Heavy Metals in Cosmetic Products by Ion Chromatography (이온 크로마토그래피를 이용한 화장품 중 중금속 동시분석)

  • Lee, So-Mi;Jeong, Hye-Jin;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.1
    • /
    • pp.57-62
    • /
    • 2008
  • No matter how small amount of heavy metals it may be cause skin allergies through percutaneous adsorption when existing in cosmetic products as impurities. In order to develop a highly sensitive method for simultaneous determination of $Pb^{2+},\;Fe^{2+},\;Cu^{2+},\;Ni^{2+},\;Zn^{2+},\;Co^{2+},\;Cd^{2+},\;and\;Mn^{2+}$ in coloring agents and cosmetic products with rapidity and accuracy, we carried out the determination on ion chromatography. All of these metals are well separated through a bifunctional ion-exchange column(IonPac CS5A) and detected by post-column reaction and spectrophotometric detection. The calibration graphs are linear($r^2>0.999$) in the range $0.1{\sim}1000{\mu}g/mL$. Detection limits for 200 ${\mu}L$ of sample solution are at the level of ${\mu}g/L$, which is sufficient for judging whether the product is safe or not. The relative standard deviations(RSDs) of the retention time and the peak area are less than 0.21 and 1.24%, respectively. The recovery rates are $97{\sim}104%$. The new method was applied to analyze the amount of heavy metals which were contained in 22 cosmetic products and 11 coloring agents.