• Title/Summary/Keyword: Skewness Method

Search Result 187, Processing Time 0.029 seconds

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Detection of TFT-LCD Defects Using Independent Component Analysis (독립성분분석을 이용한 TFT-LCD불량의 검출)

  • Park, No-Kap;Lee, Won-Hee;Yoo, Suk-In
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.5
    • /
    • pp.447-454
    • /
    • 2007
  • TFT-LCD(Thin Film transistor liquid crystal display) has become actively used front panel display technology with increasing market. Intrinsically there is region of non uniformity with low contrast that to human eye is perceived as defect. As the gray level difference between the defect and the background is hardly distinguishable, conventional thresholding and edge detection techniques cannot be applied to detect the defect. Between the patterned and un-patterned LCD defects, this paper deals with un-patterned LCD defects by using independent component analysis, adaptive thresholding and skewness. Our method showed strong results even on noised LCD images and worked successfully on the manufacturing line.

A Comparison of Confidence Intervals for the Difference of Proportions (모비율 차이의 신뢰구간들에 대한 비교연구)

  • 정형철;전명식;김대학
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.377-393
    • /
    • 2003
  • Several confidence interval estimates for the difference of two binomial proportions were introduced. Bootstrap confidence interval is also suggested. We examined the over estimation property of approximate intervals and under estimation trend of exact intervals for the difference of proportions. We compared these confidence intervals based on the average coverage probability, expected width and skewness measure. Particularly actual coverage probability were calculated by using the prior distribution of parameters. Monte Carlo simulation for small sample size is conducted. Some interesting contour plots of average coverage probability and marginal plots for several interval estimates are presented.

An Experimental Study on the Swirling Flow Field in the Tangentially Fired Furnace (접선식 배치로내의 선회유동장에 관한 실험적 연구)

  • ;;;Yoon, S. H.;Sim, J. K.;Song, H. B.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3003-3013
    • /
    • 1995
  • The characteristics of the flow field in the tangentially fired furnace are presented. Experiments are conducted in the simplified cold type isothermal flow model. In the measurement of flow field, a hot wire anemometer is used. The hot wire was calibrated by lookup table method. The mean velocity field and turbulence characteristics are showed with changing the nozzle angle. In the center of the model, the low speed, unstable flow region is formed. The size and position of these regions are varied with changing the nozzle angle. It can be used as fundamental data in the design of the large furnace. From the experimental results, various turbulent characteristics of swirling flow field is obtained. And the entrainment mechanism of the jet flow field is described from the distribution of the skewness and the flatness. It can be used the raw data of approximate calculation and turbulent modelling.

Improvement of Historical-Hanja Recognition Using a Nonlinear Transform of Contour Directional Feature Vectors

  • Kim, Min Soo;Kim, Jin Hyung
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.3
    • /
    • pp.503-511
    • /
    • 2004
  • In Korea, OCR-based techniques have been developed for digital library construction of historical documents. In this paper, we propose the nonlinear transform of contour directional feature (CDF) vectors using log it and power transforms with skewness criterion to enhance the discriminant power. Experiments were conducted using samples from Seung-jung-won diaries (Diaries of King's Secretaries). Our results show that proposed method outperforms the others like Box-Cox transform in this database.

Relationship Between the Mean and Median in a Skewed Frequency Distribution

  • Shin, Mi-Young;Cho, Tae Kyoung
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.3
    • /
    • pp.513-518
    • /
    • 2004
  • The well-known mode-mean-median inequality for the unimodal population distribution does not always hold for the frequency distribution. But many elementary statistics text books just mention that the relative location of the mean and median can be used to determine whether a distribution is positively or negatively skewed. In this paper we introduce the method generating data that is positively skewed but mean

Feature Extraction of Simulated fault Signals in Stator Windings of a High Voltage Motor and Classification of Faulty Signals

  • Park, Jae-Jun;Jang, In-Bum
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.965-975
    • /
    • 2005
  • In the case of the fault in stator windings of a high voltage motor. it facilitates certain destructive characteristics in insulations. This will result in a decreased reliability in power supplies and will prevent the generation of electricity, which will result in huge economic losses. This study simulates motor windings using normal windings and four faulty windings for an actual fault in stator winding of a high voltage motor. The partial discharge signals produced in each faulty winding were measured using an 80 PF epoxy/mica coupler sensor. In order to quantified signal waves its a way of feature extraction for each faulty signal, the signal wave of winding was quantified to measure the degree of skewness shape and kurtosis, which are both types of statistical parameters, using a discrete wavelet transformation method for each faulty type. Wave types present different types lot each faulty type, and the skewness and kurtosis also present different quantified values. The result of feature extraction was used as a preprocessing stage to identify a certain fault in stater windings. It is evident that the type of faulty signals can be classified from the test results using faulty signals that were randomly selected from the signal, which was not applied in the training after the training and learning period, by applying it to a back-propagation algorithm due to the supervising and learning method in a neural network in order to classify the faulty type. This becomes an important basis for studying diagnosis methods using the classification of faulty signals with a feature extraction algorithm, which can diagnose the fault of stator windings in the future.

A study for the efficiency of the cut-off method in highly skewed populations (왜도(Skewness)가 심한 모집단에서의 절사법효과에 관한 연구)

  • 한근식;김용철
    • The Korean Journal of Applied Statistics
    • /
    • v.9 no.2
    • /
    • pp.161-169
    • /
    • 1996
  • In the design of the sampling, it is important to make a decision about the size of the sample to be selected from the population. We often have a problem to get the optical size of the sample to be considered for cost and time expended for selecting sample unit from highly skewed population. In this case, we give a graphical criterion with Take-all Stratum rate to choose a method and also illustrate the efficiency between the Neyman allocation and the cut-off method with real data.

  • PDF

A Statistical Method of Estimation of Extreme Sea Level (극한 파고 추정의 통계적 방법)

  • Gwon, Sun-Hong;Lee, Tae-Il;Jeon, Yeong-Gi
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.43-50
    • /
    • 1991
  • 본 연구에서는 극한 파고를 추정하는 방법을 제시하였다. Type III분포에 근거해서 4가지의 방법들에 의해 분포 함수의 파라미터들을 추정하였다. 실제 자료와 추정된 분포 함수 값의 차이를 다항식을 도입하여 함으로써 그 오차를 줄였다. 이 방법들의 타당성을 보이기 위해 실제 해상의 자료들을 이용하여 분포 함수를 구하고 조우 주기들에 해당하는 극한 파고를 계산하여 보았다.

  • PDF

A Study on Diagnosis of Transformers Aging Sate Using Wavelet Transform and Neural Network (이산웨이블렛 변환과 신경망을 이용한 변압기 열화상태 진단에 관한 연구)

  • 박재준;송영철;전병훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.1
    • /
    • pp.84-92
    • /
    • 2001
  • In this papers, we proposed the new method in order to diagnosis aging state of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion skewness, kurtosis) about each acoustic emission signal. Also, these coefficients are used to identify normal and fault signal of internal partial discharge in transformer. As improved method for classification use neural network. Extracted statistical parameters are input into an back-propagation neural network. The number of neurons of hidden layer are obtained through Result of Cross-Validation. The network, after training, can decide whether the test signal is early aging state, alst aging state or normal state. In quantity analysis, capability of proposed method is superior to compared that of classical method.

  • PDF