• 제목/요약/키워드: Sizing system

검색결과 576건 처리시간 0.032초

손측정변수들 간의 연관성 분석을 통한 장갑설계의 중요변수 결정 및 치수체계 적용 (Determination and Application of Key Dimensions for a Sizing System of Glove by Analyzing the Relationshiops Between Hand Anthropometric Variables)

  • 권오채;정기효;선미선;유희천;김희은
    • 대한인간공학회지
    • /
    • 제23권3호
    • /
    • pp.25-38
    • /
    • 2004
  • Selection of a key dimension (s) by considering the characteristics of hand dimensions is needed to design gloves and construct a sound sizing system for gloves The present study identified key dimensions of glove design by analyzing the relationships between hand dimensions and demonstrated the construction process of a glove sizing system. By conducting correlation and regression analyses on 70 hand dimensions including 3 key dimension candidates (hand length; hand circumference; hand breadth) with the 1988 US Army data, hand length and hand circumference were selected as key dimensions for glove design. Glove sizing systems were constructed for males and females by applying the selected key dimensions, 0.5 inch of sizing intervals, and 2% of presence rate criterion to the US Army data. This study suggests that glove sizing systems for males and females be very different from each other and a glove sizing system for males include more sizes than that for females.

4륜구동 직렬형 하이브리드 전기추진시스템의 구성품 용량 최적화 연구 (A Study on Optimization of Components Sizing for 4×4 Series Hybrid Electric Propulsion Systems)

  • 장명언;정순규;한규홍;여승태
    • 한국군사과학기술학회지
    • /
    • 제17권2호
    • /
    • pp.159-166
    • /
    • 2014
  • The study is conducted on the subject of optimization of components sizing for series hybrid electric propulsion systems. The components sizing of series type hybrid system is very important because each component of series type is larger than the corresponding component of the parallel type or series-parallel type. If the components sizing is greater or less than what is required to this system, the performance of the system is getting worse. The methodology for the sizing of a driving motor is introduced based on the foundation of determined system configuration and performance target. And the sizing of an engine/generator and a battery is achieved based on simulation results using Dynamic Programming. It is possible to find the optimal sizing of these components by comparing fuel efficiency of hybrid electric propulsion system for 8 driving cycles.

아동화의 치수규격설계를 위한 탐색적 연구 (A Tentative Study on Sizing System for Children's Shoes)

  • 전은경;권숙희
    • 한국생활과학회지
    • /
    • 제16권1호
    • /
    • pp.173-181
    • /
    • 2007
  • This is a tentative study to provide prototype of sizing system for children's shoes. For this study, 364 elementary school girls from KyungIn and YeongNam areas were participated in the measurement. The results of the analysis on four measurement items related to foot can be summarized as followings: 1. All of the foot related items were increased according to their growth. Especially, foot length, foot width, and toe width showed a high correlation. 2. The result also revealed that the current sizing system can cover only 70.9% of children in measurement, which means that a new sizing system is required. 3. We suggested a new standard size for foot size/foot circumference based on the results above according to current sizing system, and a new standard size for foot circumference/foot width based on ISO standard. The results of this study would be helpful in the design of sizing system of children's shoe if applied with the raw data of the Size Korea recently measured.

청소년 전기 남학생의 상의 치수 체계에 관한 연구 (The Apparel Sizing System of the Upper Garments for Early Adolescent Boys)

  • 김경아;어미경;서미아
    • 복식문화연구
    • /
    • 제15권6호
    • /
    • pp.1008-1022
    • /
    • 2007
  • The purpose of this study is to propose apparel sizing system for each body shape of early adolescent boys. The subjects of this study were 549 boys in the capital area. Their body shapes were classified and apparel sizing system was proposed for each body shape. For data analysis were performed descriptive statistics, correlation analysis and crosstabulation using SPSS Ver. 12. The control dimensions to propose apparel sizing system were stature and bust circumference for the upper garments. Intervals between sizes were 5cm for stature and irregular for bust circumference. For each type, $5{\sim}7$ sizes were proposed for upper garments. Reference measurements suggested for upper garments were 9 items. This study is meaningful in that it classified early adolescent boys' body shapes and proposed apparel sizing system for each type of body shape under the current circumstances where basic data for body shape classification and apparel sizing system of early adolescent boys were not in place.

  • PDF

비만 여성의 의복 치수체계 및 커버율에 판한 연구 (A Study on the Cover Ratio and the Sizing System of Apparels for Obese Women)

  • 이진희
    • 한국의류학회지
    • /
    • 제22권6호
    • /
    • pp.737-748
    • /
    • 1998
  • This study was carried out on 132 obese women who satisfied both of conditions for obesity: equal to or over 1.6 in Rohrer index and 90 in bust girth. The purpose of the study was to set up a sizing system using the loss function which would be a guide for obese women to select ready-to-wear of suitable size. The results were as follows. 1) In the sizing system for large size apparel industry, each company has 4 to 7 sizes that differ in their content and number. Producing only 5 sizes was trying to minimize the producti on expenses. 2) The sizing system according to the loss function was the follwings. The height was 3: 149, 154.5 and 161 cm. The bust girth was 5:96.5, 100.5, 104, 107.5, 112 cm. The hip girth was 5: 95, 99, 102.5, 105.5, 110 cm. 3) In comparing the cover ratio of the newly suggested sizing system for obese women's garment with that of the Korea Sizing system for women's garment, the former was founded to have the greater cover ratio.

  • PDF

한국인의 의복 제작을 위한 체형별 사이징 체계 개발 (A Methodology for Developing a Korean Apparel Sizing System by Body Types)

  • 성덕현;정의승;조용주
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.31-37
    • /
    • 2005
  • Resulting anthropometric data recently measured and cataloged through 5th national anthropometric survey that is called Size Korea is highly useful in clothing industries. This study aims at suggesting a statistical methodology for apparel sizing that reflects recent changes in Korean anthropometry and improves customer fitness. Based on previous research on body types such as triangular, rectangular, inverted body types, etc., factors that represent human sizes were extracted and then clustered into groups by their body types. These body type-based groups with respect to the factors obtained yielded a sizing system of which the interval of each factor is of equi-distance by their factor scores. However, each interval of the sizing system is non-linear in terms of individual anthropometric variables. The sizing system being proposed in this study was compared to that of KS K 0050 and had a broader coverage for the Korean population surveyed. The apparel sizing scheme is expected to improve customer fitness when applied to garment sizing and to provide more information on what percentage of population is included in each classification.

의료용 압박스타킹의 사이즈 체계에 관한 연구 -한국 시장에서의 수입 의료용 압박스타킹을 중심으로- (Sizing System for Medical Compression Stockings -Focus on Imported Medical Compression Stockings in the Korean Market-)

  • 도월희;김남순
    • 한국의류학회지
    • /
    • 제36권8호
    • /
    • pp.860-874
    • /
    • 2012
  • This study provides size information on current imported medical compression stockings in Korea. A total 20 brands from 6 countries imported and sold in the Korean on-off line markets were selected for this study and the sizing system of medical compression stockings was researched. The results of this study were as follows: there were size differences among different USA brands according to product type or compression class of medical compression stockings. To establish the sizing system for medical stockings of the German brands, the basic body measurements standard was set as cA, cY, cB, cB, cC, cD, cE, cF, cG, cH, cT, lD, lG, and lT. Italian brands developed the sizing system for medical compression stockings by compression class. In the Swiss brands, size types were sub-divided as 'Normal', 'Plus', 'Short', and 'Long'. The sizing 1 were confined within very narrow limits. There were differences of the basic body measurements between Taiwan brands. The results of the comparison of the size range of the imported brands with Size Korea (KATS, 2010) by two-way size distribution shows that the sizing systems of the imported brands were unsuitable for Koreans. To enhance the suitability of the sizing system for medical compression stockings, a new sizing system for Korean adult males and females needs to be established.

치수체계의 신체 적합도를 개선하기 위한 수리적 방법 연구: -미국 해군 여성의 신체측정치를 중심으로-

  • 김미숙;김정룡
    • 대한인간공학회지
    • /
    • 제16권1호
    • /
    • pp.47-61
    • /
    • 1997
  • A statistical method was developed to examine the US navy women's sizing system. Subjects including 906 navy female personnels were classified into seven groups based on the body type. Regression analyses were performed within seven groups to determine the sizing system maximizing the fitness of clothing in each group. New parameters were developed and used to statistically investigate the fitness level based upon boty navy sizing system and regression based system in this study. A customizef SAS program was used to compute the fitness levels. Results indicated that the navy sizing system showed lower fitness level in most groups except Juniour than the regression based system. It was concluded that the current method with new parameters could be used as an objective tool to evaluate the existing or new sizing system. This method can be further validated in other sample populations.

  • PDF

시판 유아용 커버롤의 치수적합성에 관한 연구 (A Study on the Appropriateness of the Current Sizing System of Infant Coveralls)

  • 도월희;최혜선;김은경
    • 한국의류학회지
    • /
    • 제27권2호
    • /
    • pp.277-288
    • /
    • 2003
  • The purpose of this study was to provide information on how to improve the current sizing system of infant coveralls through analysis of the present system. In order to compile the information about dissatisfaction with the appropriateness of the fit of infant coveralls, a questionnaire was administered to mothers of 241 infants (aged under 36 months) living in Seoul, and analyzed using the SPSS WIN.10.0 program. Also, the manufacturers'basic body sizes were investigated. The results of this study were as follows : 1. The results of the comparison between the manufacturers'basic body sizes and the body measurement values obtained as the physical standard of the nation(1997) show that in terms of length and hip circumference, the manufacturers'body sizes were larger. On the other hand, in the waist circumference, the manufacturers'body sizes were smaller than the national average. 2. Research on the production sizing system of domestic and international brands, showed that the sizing interval of domestic brands were 6 months, whereas the international brands were 3 months f3r infants under 12 months. 3. Concerning fit, the areas causing most dissatisfaction were: the trunk length, sleeve length, inside leg length, and neck depth. The results showed that dissatisfaction with the suitability of the sizing of current infant coveralls according to the body part differed among the groups according to the month of age.

액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법 (Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior)

  • 이지영;김경철;김철환;;박현진;김성호;심성웅;조후승
    • 펄프종이기술
    • /
    • 제44권2호
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.