• Title/Summary/Keyword: Size separation

Search Result 955, Processing Time 0.023 seconds

Hospital Financial Performances and Separation of Dispensary from Medical Practice (의약분업 전후 병원 재무성과의 변화)

  • Jung, Kyu-Eon;Ju, Jeong-Bun;Kim, Young-Kyu
    • Korea Journal of Hospital Management
    • /
    • v.9 no.3
    • /
    • pp.49-70
    • /
    • 2004
  • This study analyzes the effect of separation of dispensary from medical practice on hospital management performance. The results are as follow. The earning ratios of large size hospitals become deteriorated significantly after the separation of dispensary. The growth ratios of revenues from inpatient were unchanged, but the growth ratios of revenues from outpatient of large and middle size hospitals were decreased significantly. Hospitals can't sell the medicines to the outpatient after the separation of dispensary, but they can do to the outpatient. The labor cost ratios of small and large size hospitals are increased significantly after the separation of dispensary. There are two reasons for increase of labor cost ratios. One is the decrease of material cost ratio. The other is the increase of doctor's salary. The material cost ratios of every size hospital are decreased significantly after the separation of dispensary. Because medicines costs of outpatients are decreased. The labor cost and doctors' salary per patient of middle and large size hospitals are increased significantly after the separation of dispensary. And average treatment fees per day of inpatients of middle and large size hospitals are increased significantly after the separation of dispensary. But those of outpatients are decreased significantly. Average numbers of outpatients per bed of small and large hospitals are decreased significantly after the separation of dispensary. And average numbers of inpatients per bed of large hospitals are decreased significantly. In summary, as a consequence of separation of dispensary from medical practice, management performances of large size hospitals become deteriorated significantly.

  • PDF

Microstructure and Pore Size Control of Silica Membrane for Gas Separation at Elevated Temperatures

  • Lee Kew-Ho;Sea Bongkuk;Lee Dong-Wook
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.42-50
    • /
    • 2005
  • Among ceramic membranes developed to date, amorphous silica membranes are attractive for gas separation at elevated temperatures. Most of the silica membranes can be formed on a porous support by sol-gel or chemical vapor deposition (CVD) process. To improve gas permselectivity of the membrane, well-controlled pores having desired size and chemical affinity between permeates and membrane become important factors in the preparation of membranes. In this article, we review the literature and introduce our technologies on the microstructure to be solved and pore size control of silica membranes using sol-gel and CVD methods.

Effects of Competition between Phase Separation and Ester Interchange Reactions on the Phase Behavior in a Phase-Separated Immiscible Polyester Blend: Monte Carlo Simulation

  • Youk, Ji-Ho;Jo, Won-Ho
    • Fibers and Polymers
    • /
    • v.2 no.2
    • /
    • pp.81-85
    • /
    • 2001
  • The effects of rate of phase separation to ester interchange reactions and the repulsive pair interaction energy on the phase behavior in a phase-separated immiscible polyester blend are investigated using a Monte Carlo simulation method. The time evolution of structure factor and the degree of randomness are monitored as a function of homogenization time. When the phase separation is dominant over ester interchange reactions, the domain size slowly increases with homogenization time. However, when the pair interaction becomes less repulsive, the domain size does not significantly change with homogenization time. On the other hand, when ester interchange reactions are dominant over the phase separation, the homogenization proceeds without a change in the domain size. The higher the extent of phase separation, the lower the increasing rate of the DR. However, when the phase separation is sufficiently dominant, the effect of the extent of phase separation on the increasing rate of the degree of randomness become less significant.

  • PDF

Development of volume reduction method of cesium contaminated soil with magnetic separation

  • Yukumatsu, Kazuki;Nomura, Naoki;Mishima, Fumihito;Akiyama, Yoko;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.10-13
    • /
    • 2016
  • In this study, we developed a new volume reduction technique for cesium contaminated soil by magnetic separation. Cs in soil is mainly adsorbed on clay which is the smallest particle constituent in the soil, especially on paramagnetic 2:1 type clay minerals which strongly adsorb and fix Cs. Thus selective separation of 2:1 type clay with a superconducting magnet could enable to reduce the volume of Cs contaminated soil. The 2:1 type clay particles exist in various particle sizes in the soil, which leads that magnetic force and Cs adsorption quantity depend on their particle size. Accordingly, we examined magnetic separation conditions for efficient separation of 2:1 type clay considering their particle size distribution. First, the separation rate of 2:1 type clay for each particle size was calculated by particle trajectory simulation, because magnetic separation rate largely depends on the objective size. According to the calculation, 73 and 89 % of 2:1 type clay could be separated at 2 and 7 T, respectively. Moreover we calculated dose reduction rate on the basis of the result of particle trajectory simulation. It was indicated that 17 and 51 % of dose reduction would be possible at 2 and 7 T, respectively. The difference of dose reduction rate at 2 T and 7 T was found to be separated a fine particle. It was shown that magnetic separation considering particle size distribution would contribute to the volume reduction of contaminated soil.

Blind Source Separation U sing Variable Step-Size Adaptive Algorithm in Frequency Domain

  • Park Keun-Soo;Lee Kwang-Jae;Park Jang-Sik;Son Kyung Sik
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.6
    • /
    • pp.753-760
    • /
    • 2005
  • This paper introduces a variable step-size adaptive algorithm for blind source separation. From the frequency characteristics of mixed input signals, we need to adjust the convergence speed regularly in each frequency bin. This algorithm varies a step-size according to the magnitude of input at each frequency bin. This guarantee of the regular convergence in each frequency bin would become more efficient in separation performances than conventional fixed step-size FDICA. Computer simulation results show the improvement of about 5 dB in signal to interference ratio (SIR) and the better separation quality.

  • PDF

A Continuous Particle-size Sorter Using Negative a Dielectrophoretic Virtual Pillar Array (음의 유전영동에 의한 가상 기둥 어레이를 이용한 연속적 입자 크기 분류기)

  • Chang, Sung-Hwan;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.824-831
    • /
    • 2008
  • We present a continuous size-dependent particle separator using a negative dielectrophoretic (DEP) virtual pillar array. Two major problems in the previous size-dependent particle separators include the particle clogging in the mechanical sieving structures and the fixed range of separable particle sizes. The present particle separator uses the virtual pillar array generated by negative DEP force instead of the mechanical pillar array, thus eliminating the clogging problems. It is also possible to adjust the size of separable particles since the size of virtual pillars is a function of a particle diameter and applied voltage. At an applied voltage of 500 kHz $10\;V_{rms}$ (root mean sqaure voltage) sinusidal wave and a flow rate of $0.40\;{\mu}l\;min^{-1}$, we separate $5.7\;{\mu}m$-, $8.0\;{\mu}m$-, $10.5\;{\mu}m$-, and $11.9\;{\mu}m$-diameter polystyrene (PS) beads with separation purity of 95%, 92%, 50%, and 63%, respectively. The $10.5\;{\mu}m$- and $11.9\;{\mu}m$-diameter PS beads have relatively low separation purity of 50% and 63%. However, at an applied voltage of $8\;V_{rms}$, we separate $11.9\;{\mu}m$-diameter PS beads with separation purity over 99%. Therefore, the present particle separator achieves clog-free size-dependent particle separation, which is capable of size tuning of separable particles.

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

Microfluidic cell sizing using hydrophoretic size-based separation (유체영동 기반의 입자분리현상을 이용한 세포 크기 측정방법)

  • Choi, Sung-Young;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.245-249
    • /
    • 2008
  • This paper presents a microfluidic cell sizing method using hydrophoretic size-based separation. By exploiting slanted obstacles in a microchannel, we can generate a lateral pressure gradient so that microparticles can be deflected and arranged along lateral flows induced by the gradient. Using such movement of particles, we discriminated 8 to 15 μm-sized beads. We measured the size of U937 cells by comparing the hydrophoretic response of the cells to those of the size-standard beads whose diameters are known. Due to its simple design and fabrication, the sizing method can be easily integrated with other microfluidic components such as cell culture chambers conducting on-chip sizing and sorting.

Utilization of functionalized magnetic nanoparticles for high throughput DNA separation

  • Jang, Jeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.12.2-12.2
    • /
    • 2009
  • The work describes anoptimized process to highly efficient and convenient preparation in highthroughput magnetic human DNA separation with chemically functionalizedsilica-coated magnetic nanoparticles. The effect of nanoparticle's size and the surface's hydrophilicity change were studied for magnetic DNA separation process, inwhich the optimum efficiency was explored via the function of the amino-groupnumbers, particle size, the amount of the nanoparticles used, and theconcentration of NaCl salt. The DNA adsorption yields were high in terms of theamount of triamino-functionalized nanoparticles used, and the average particlesize was 25 nm. The adsorption efficiency of aminofunctionalized nanoparticleswas the 4-5 times (80-100%) higher compared to silica-coated nanoparticles only(10-20%). DNA desorption efficiency showed an optimum level of over 0.7 M ofthe NaCl concentration. To elucidate the agglomeration of nanoparticles afterelectrostatic interaction, the Guinier plots were calculated from small angleX-ray diffractions in a comparison of the results of electron diffraction TEM,and confocal laser scanning microscopy. Additionally, the direct separation ofhuman genomic DNA was achieved from human saliva and whole blood with highefficiency.

  • PDF

Development of Solid Separator for Selective Solid Circulation in Two-interconnected Fluidized Beds System (2탑 유동층 시스템에서 선택적 고체순환을 위한 고체분리기 개발)

  • Ryu, Ho-Jung;Park, Young Cheol;Lee, Seung-Yong;Kim, Hong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.195-202
    • /
    • 2009
  • As a basic research of developing two-interconnected fluidized beds system for selective solid circulation, a solid separator was developed to separate fine and coarse particles by means of particle size difference with particle size separation system equipped with metal screen. The effects of gas velocity, height of solid separator, and separation area on the solid separation rate were investigated as well. The solid separation rate increased as the gas velocity, height of solid separator, and separation area increased. As the gas velocity and height of the solid separator increased, the variation of the solid separation rate was consistent with that of bubble size. Consequently, coarse($212{\sim}300{\mu}m$) and fine($63{\sim}106{\mu}m$) particles were separated using the solid separator and the solid separation rate was ranged from 4.4 to 127 g/min. We also proposed two interconnenced fluidized beds system for sorption enhanced water-gas shift process equipped with the developed solid separator.