• 제목/요약/키워드: Size separation

검색결과 955건 처리시간 0.027초

의약분업 전후 병원 재무성과의 변화 (Hospital Financial Performances and Separation of Dispensary from Medical Practice)

  • 정규언;주정분;김영규
    • 한국병원경영학회지
    • /
    • 제9권3호
    • /
    • pp.49-70
    • /
    • 2004
  • This study analyzes the effect of separation of dispensary from medical practice on hospital management performance. The results are as follow. The earning ratios of large size hospitals become deteriorated significantly after the separation of dispensary. The growth ratios of revenues from inpatient were unchanged, but the growth ratios of revenues from outpatient of large and middle size hospitals were decreased significantly. Hospitals can't sell the medicines to the outpatient after the separation of dispensary, but they can do to the outpatient. The labor cost ratios of small and large size hospitals are increased significantly after the separation of dispensary. There are two reasons for increase of labor cost ratios. One is the decrease of material cost ratio. The other is the increase of doctor's salary. The material cost ratios of every size hospital are decreased significantly after the separation of dispensary. Because medicines costs of outpatients are decreased. The labor cost and doctors' salary per patient of middle and large size hospitals are increased significantly after the separation of dispensary. And average treatment fees per day of inpatients of middle and large size hospitals are increased significantly after the separation of dispensary. But those of outpatients are decreased significantly. Average numbers of outpatients per bed of small and large hospitals are decreased significantly after the separation of dispensary. And average numbers of inpatients per bed of large hospitals are decreased significantly. In summary, as a consequence of separation of dispensary from medical practice, management performances of large size hospitals become deteriorated significantly.

  • PDF

Microstructure and Pore Size Control of Silica Membrane for Gas Separation at Elevated Temperatures

  • Lee Kew-Ho;Sea Bongkuk;Lee Dong-Wook
    • Korean Membrane Journal
    • /
    • 제7권1호
    • /
    • pp.42-50
    • /
    • 2005
  • Among ceramic membranes developed to date, amorphous silica membranes are attractive for gas separation at elevated temperatures. Most of the silica membranes can be formed on a porous support by sol-gel or chemical vapor deposition (CVD) process. To improve gas permselectivity of the membrane, well-controlled pores having desired size and chemical affinity between permeates and membrane become important factors in the preparation of membranes. In this article, we review the literature and introduce our technologies on the microstructure to be solved and pore size control of silica membranes using sol-gel and CVD methods.

Effects of Competition between Phase Separation and Ester Interchange Reactions on the Phase Behavior in a Phase-Separated Immiscible Polyester Blend: Monte Carlo Simulation

  • Youk, Ji-Ho;Jo, Won-Ho
    • Fibers and Polymers
    • /
    • 제2권2호
    • /
    • pp.81-85
    • /
    • 2001
  • The effects of rate of phase separation to ester interchange reactions and the repulsive pair interaction energy on the phase behavior in a phase-separated immiscible polyester blend are investigated using a Monte Carlo simulation method. The time evolution of structure factor and the degree of randomness are monitored as a function of homogenization time. When the phase separation is dominant over ester interchange reactions, the domain size slowly increases with homogenization time. However, when the pair interaction becomes less repulsive, the domain size does not significantly change with homogenization time. On the other hand, when ester interchange reactions are dominant over the phase separation, the homogenization proceeds without a change in the domain size. The higher the extent of phase separation, the lower the increasing rate of the DR. However, when the phase separation is sufficiently dominant, the effect of the extent of phase separation on the increasing rate of the degree of randomness become less significant.

  • PDF

Development of volume reduction method of cesium contaminated soil with magnetic separation

  • Yukumatsu, Kazuki;Nomura, Naoki;Mishima, Fumihito;Akiyama, Yoko;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.10-13
    • /
    • 2016
  • In this study, we developed a new volume reduction technique for cesium contaminated soil by magnetic separation. Cs in soil is mainly adsorbed on clay which is the smallest particle constituent in the soil, especially on paramagnetic 2:1 type clay minerals which strongly adsorb and fix Cs. Thus selective separation of 2:1 type clay with a superconducting magnet could enable to reduce the volume of Cs contaminated soil. The 2:1 type clay particles exist in various particle sizes in the soil, which leads that magnetic force and Cs adsorption quantity depend on their particle size. Accordingly, we examined magnetic separation conditions for efficient separation of 2:1 type clay considering their particle size distribution. First, the separation rate of 2:1 type clay for each particle size was calculated by particle trajectory simulation, because magnetic separation rate largely depends on the objective size. According to the calculation, 73 and 89 % of 2:1 type clay could be separated at 2 and 7 T, respectively. Moreover we calculated dose reduction rate on the basis of the result of particle trajectory simulation. It was indicated that 17 and 51 % of dose reduction would be possible at 2 and 7 T, respectively. The difference of dose reduction rate at 2 T and 7 T was found to be separated a fine particle. It was shown that magnetic separation considering particle size distribution would contribute to the volume reduction of contaminated soil.

Blind Source Separation U sing Variable Step-Size Adaptive Algorithm in Frequency Domain

  • Park Keun-Soo;Lee Kwang-Jae;Park Jang-Sik;Son Kyung Sik
    • 한국멀티미디어학회논문지
    • /
    • 제8권6호
    • /
    • pp.753-760
    • /
    • 2005
  • This paper introduces a variable step-size adaptive algorithm for blind source separation. From the frequency characteristics of mixed input signals, we need to adjust the convergence speed regularly in each frequency bin. This algorithm varies a step-size according to the magnitude of input at each frequency bin. This guarantee of the regular convergence in each frequency bin would become more efficient in separation performances than conventional fixed step-size FDICA. Computer simulation results show the improvement of about 5 dB in signal to interference ratio (SIR) and the better separation quality.

  • PDF

음의 유전영동에 의한 가상 기둥 어레이를 이용한 연속적 입자 크기 분류기 (A Continuous Particle-size Sorter Using Negative a Dielectrophoretic Virtual Pillar Array)

  • 장성환;조영호
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.824-831
    • /
    • 2008
  • We present a continuous size-dependent particle separator using a negative dielectrophoretic (DEP) virtual pillar array. Two major problems in the previous size-dependent particle separators include the particle clogging in the mechanical sieving structures and the fixed range of separable particle sizes. The present particle separator uses the virtual pillar array generated by negative DEP force instead of the mechanical pillar array, thus eliminating the clogging problems. It is also possible to adjust the size of separable particles since the size of virtual pillars is a function of a particle diameter and applied voltage. At an applied voltage of 500 kHz $10\;V_{rms}$ (root mean sqaure voltage) sinusidal wave and a flow rate of $0.40\;{\mu}l\;min^{-1}$, we separate $5.7\;{\mu}m$-, $8.0\;{\mu}m$-, $10.5\;{\mu}m$-, and $11.9\;{\mu}m$-diameter polystyrene (PS) beads with separation purity of 95%, 92%, 50%, and 63%, respectively. The $10.5\;{\mu}m$- and $11.9\;{\mu}m$-diameter PS beads have relatively low separation purity of 50% and 63%. However, at an applied voltage of $8\;V_{rms}$, we separate $11.9\;{\mu}m$-diameter PS beads with separation purity over 99%. Therefore, the present particle separator achieves clog-free size-dependent particle separation, which is capable of size tuning of separable particles.

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

유체영동 기반의 입자분리현상을 이용한 세포 크기 측정방법 (Microfluidic cell sizing using hydrophoretic size-based separation)

  • 최성용;박제균
    • 센서학회지
    • /
    • 제17권4호
    • /
    • pp.245-249
    • /
    • 2008
  • This paper presents a microfluidic cell sizing method using hydrophoretic size-based separation. By exploiting slanted obstacles in a microchannel, we can generate a lateral pressure gradient so that microparticles can be deflected and arranged along lateral flows induced by the gradient. Using such movement of particles, we discriminated 8 to 15 μm-sized beads. We measured the size of U937 cells by comparing the hydrophoretic response of the cells to those of the size-standard beads whose diameters are known. Due to its simple design and fabrication, the sizing method can be easily integrated with other microfluidic components such as cell culture chambers conducting on-chip sizing and sorting.

Utilization of functionalized magnetic nanoparticles for high throughput DNA separation

  • 장정호
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.12.2-12.2
    • /
    • 2009
  • The work describes anoptimized process to highly efficient and convenient preparation in highthroughput magnetic human DNA separation with chemically functionalizedsilica-coated magnetic nanoparticles. The effect of nanoparticle's size and the surface's hydrophilicity change were studied for magnetic DNA separation process, inwhich the optimum efficiency was explored via the function of the amino-groupnumbers, particle size, the amount of the nanoparticles used, and theconcentration of NaCl salt. The DNA adsorption yields were high in terms of theamount of triamino-functionalized nanoparticles used, and the average particlesize was 25 nm. The adsorption efficiency of aminofunctionalized nanoparticleswas the 4-5 times (80-100%) higher compared to silica-coated nanoparticles only(10-20%). DNA desorption efficiency showed an optimum level of over 0.7 M ofthe NaCl concentration. To elucidate the agglomeration of nanoparticles afterelectrostatic interaction, the Guinier plots were calculated from small angleX-ray diffractions in a comparison of the results of electron diffraction TEM,and confocal laser scanning microscopy. Additionally, the direct separation ofhuman genomic DNA was achieved from human saliva and whole blood with highefficiency.

  • PDF

2탑 유동층 시스템에서 선택적 고체순환을 위한 고체분리기 개발 (Development of Solid Separator for Selective Solid Circulation in Two-interconnected Fluidized Beds System)

  • 류호정;박영철;이승용;김홍기
    • Korean Chemical Engineering Research
    • /
    • 제47권2호
    • /
    • pp.195-202
    • /
    • 2009
  • 선택적 고체순환이 가능한 2탑 유동층 공정 개발을 위한 기초연구로 금속 망이 장착된 입자크기분리 시스템에 의해 입자크기 차이를 이용하여 고운입자와 굵은입자를 분리할 수 있는 고체분리기를 개발하였으며 고체분리속도에 미치는 유속, 고체분리기의 설치높이 및 분리면적의 영향을 측정 및 고찰하였다. 고체분리기에 의한 고체분리속도는 기체유속, 고체분리기의 설치높이, 분리면적이 증가함에 따라 증가하였다. 기체유속 및 고체분리기 설치높이 증가에 따른 고체분리속도의 변화경향은 기포크기의 변화경향과 유사하였다. 본 연구에서 개발한 고체분리기를 이용하여 굵은입자($212{\sim}300{\mu}m$)와 고운입자($63{\sim}106{\mu}m$)의 분리가 가능하였으며 고체분리속도는 4.4~127 g/min의 범위를 나타내었다. 개발된 고체분리기를 회수증진 수성가스변환 공정에 적용하여 선택적 고체순환이 가능한 2탑 유동층 공정구성을 제안하였다.