• 제목/요약/키워드: Size distributions

검색결과 1,180건 처리시간 0.033초

간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교 (Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site)

  • 박병도;정상훈;박성호;곽정원;김종훈;윤상민;안승도
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.106-113
    • /
    • 2012
  • 본 연구에서는 종양이 간원개에 위치한 환자들을 대상으로 Eclipse 치료계획시스템(treatment planning system V8.9 : TPS, Varian)에서 쓰이는 두 종류의 선량계산 알고리즘(pencil beam convolution : PBC, anisotropic Analytical algorithm : AAA)들을 적용하여 육안적종양체적(gross tumor volume : GTV), 내부표적체적(internal target volume : ITV), 계획용표적체적(planning target volume : PTV) 및 주요 관심장기에 전달되는 선량의 변화를 정량적으로 평가하고, 선량분포에 영향을 미칠 수 있는 인자들을 분석하고자 하였다. 본원에서 치료받은 간암환자 20명을 대상으로 하였고 그 중 10명의 환자들에 대해서는 정위적 방사선치료(stereotactic body radiation therapy : SBRT) 기술을 적용, 다른 10명의 환자들에 대해서는 3차원 입체조형 방사선치료(three-dimensional conformal radiation therapy : 3DCRT) 기술을 적용하여 치료하였다. 조사선량은 우선적으로 PBC 알고리즘을 적용하여 선량계산을 하였고 동일한 빔 정렬 및 콜리메이터(Collimator), Monitor Unit (MU) 그리고 Field 가중치를 적용시켜서 AAA 선량계산법으로 다시 계산 한 후, 두 알고리즘에 대한 처방선량 100%에 해당하는 체적(V100)의 lesion coverage factor (CVF) 들을 비교하였다. SBRT 기술을 이용한 환자들의 치료계획에서 전체 PTV에 대한 CVF의 경우, 두 선량계산 알고리즘사이 통계학적으로 유의한 상관관계(p=0.018)를 보였다. 또한, 3DCRT 기술을 이용한 환자들의 치료계획에서는 전체 PTV (p=0.006), 간원개에 위치한 PTV (p=0.013), 전체 ITV (p=0.024)에 대하여 각각 통계학적으로 유의한 상관관계를 보였다. 복부에 위치한 주요 관심장기에 대하여 SBRT 기술을 이용한 환자들의 치료계획에서 정상 간과 신장에 조사되는 최대선량에 대하여 통계학적으로 각각 유의한 상관관계(정상간: p=0.009, 신장: p=0.037)를 보였다. 본 연구에서 선택한 선량변화 예측인자들에 대하여 대응표본 T-검정(paired T-test)을 시행한 결과, 전체 PTV에 대한 간원개에만 위치하는 PTV의 비율($PTV_{dome}$/PTV)과 두 알고리즘에 의한 CVF 비율의 상관관계에 있어서 통계학적으로 유의미한 상관관계를 보였다(p<0.01). 또한, 종양의 크기에 대한 두 알고리즘의 CVF 비율에 있어서 통계학적으로 의미가 있는 상관관계를 보였다(SRS환자 p=0.017, 3DCRT환자 p=0.023). 본 연구에서는 15MV x-ray beam으로 선량을 계산할 때 PBC와 AAA간의 선량계산 차이를 분석하여 선택한 선량변화 예측인자 중 간원개에 위치한 종양의 크기와 계획용 표적체적에 대한 관계성을 알아내었다. 일반적으로 15MV x-ray beam에 의한 선량분포를 정확하게 알아내는 것은 AAA으로도 불충분하다는 것이 일반적인 사실로 받아들여지고 있어 이를 AAA와 PBC간의 차이로 그 정확성을 간접적으로 유추하여 실질적인 선량분포에 대한 치료계획단계에서의 선량분포의 차이의 경향성을 보고자 하였다.

暴雨의 時間的 分布에 關한 硏究 (Studies on the Time Distribution of Heavy Storms)

  • 이근후
    • 한국농공학회지
    • /
    • 제26권2호
    • /
    • pp.69-84
    • /
    • 1984
  • This study was carried out to investigate the time distribution of single storms and to establish the model of storm patterns in korea. Rainfall recording charts collected from 42 metheorological stations covering the Korean peninsula were analyzed. A single storm was defined as a rain period seperated from preceding and succeeding rainfall by 6 hours and more. Among the defined single storms, 1199 storms exceeding total rainfall of 80 mm were qualified for the study. Storm patterns were cklassified by quartile classification method and the relationship between cummulative percent of rainfalls and cummulative storm time was established for each quartile storm group. Time distribution models for each stations were prepared through the various analytical and inferential procedures. Obtained results are summarized as follows: 1. The percentile frequency of quartile storms for the first to the fourth quartile were 22.0%, 26.5%, 28.9% and 22.6%, respectively. The large variation of percentile frequency was show between the same quartile storms. The advanced type storm pattern was predominant in the west coastal type storm patterns predominantly when compared to the single storms with small total rainfalls. 3. The single storms with long storm durations tended to show delayed type storm patterns predominantly when compared to the single storms with short storm durations. 4. The percentile time distribution of quartile storms for 42 rin gaging stations was estimated. Large variations were observed between the percentiles of time distributions of different stations. 5. No significant differences were generally found between the time distribution of rainfalls with greater total rainfall and with less total rainfall. This fact suggests that the size of the total rainfall of single storms was not the main factor affecting the time distribution of heavy storms. 6. Also, no significant difference were found between the time distribution of rainfalls with long duration and with short duration. The fact indicates that the storm duration was no the main factor affecting the time distribution of heavy storms. 7. In Korea, among all single storms, 39.0% show 80 to 100mm of total rainfall which stands for the mode of the frequency distribution of total rainfalls. The median value of rainfalls for all single storms from the 42 stations was 108mm. The shape of the frequency distribution of total rainfalls showed right skewed features. No significant differences were shown in the shape of distribution histograms for total rainfall of quartile storms. The mode of rainfalls for the advanced type quartile storms was 80~100mm and their frequencies were 39~43% for respective quartiles. For the delayed type quartile storms, the mode was 80~100mm and their frequencies were 36!38%. 8. In Korea, 29% of all single storms show 720 to 1080 minutes of storm durations which was the highest frequency in the frequency distribution of storm durations. The median of the storm duration for all single storms form 42 stations was 1026 minutes. The shape of the frequency distribution was right skewed feature. For the advanced type storms, the higher frequency of occurrence was shown by the single storms with short durations, whereas for the delayed type quartile storms, the higher frequency was shown gy the long duration single storms. 9. The total rainfall of single storms was positively correlated to storm durations in all the stations throughout the nation. This fact was also true for most of the quartile storms. 10. The third order polynomial regression models were established for estimating the time distribution of quartile storms at different stations. The model test by relative error method resulted good agreements between estimated and observed values with the relative error of less than 0.10 in average.

  • PDF

수정된 폴리올 방법을 적용하여 합성한 PtM 촉매들의 산소환원반응성 연구 (A Study on Oxygen Reduction Reaction of PtM Electrocatalysts Synthesized by a Modified Polyol Process)

  • 양종원;현규환;추천호;권용재
    • 공업화학
    • /
    • 제25권1호
    • /
    • pp.78-83
    • /
    • 2014
  • 본 연구에서는 수정된 폴리올법에 의해 합성된 백금-이트륨 및 백금-니켈 합금 촉매들의 성능 및 특성 평가를 진행하였다. 그렇게 합성된 합금 촉매들은 고분자전해질연료전지의 공기극 촉매로 사용되며 그 촉매들의 산소환원반응성 및 연료전지의 전기적 성능이 측정되고 상업적으로 사용되는 백금 촉매와 해당하는 결과들이 비교되었다. 성능 및 특성 비교를 위해, 백금 합금 촉매들의 입자크기와 분포는 투과전자현미경에 의해 관측되었고 활성표면적은 반복주사 전압-전류법에 의해 측정되었으며 그들의 산소환원반응성 및 연료전지의 전기적 성능은 회전원판 및 회전-고리 원판전극을 이용한 선형주사 전압-전류법 및 완전지 테스트를 통해 평가되었다. 그 결과 백금 합금 촉매들의 구조적 특성인 입자크기 및 분포 및 활성표면적은 상용 백금 촉매와 그 특성이 비슷하였다. 촉매들의 산소환원반응성의 경우에도 백금 합금 촉매들은 상용 백금 촉매와 비슷하거나 더 나은 반파장전위, 속도론적 전류밀도, 산소분자당 전이되는 전자수, 과산화수소 생성율을 나타내었다. 촉매의 구조적 특성 및 산소환원반응성에 입각해서 완전지 성능을 평가했을 때, 백금 합금 촉매들은 상용백금 촉매보다 더 우수한 0.6 V에서 전류밀도 및 최대출력밀도 값을 나타내었다. 이를 토대로 수정된 폴리올법에 의해 합성된 백금 합금 촉매들은 상용백금 촉매보다 비슷하거나 우수한 산소환원반응성 및 완전지 성능을 가질 수 있음을 제시하였다.

기계학습을 활용한 동아시아 지역의 TROPOMI 기반 SO2 지상농도 추정 (Estimation of TROPOMI-derived Ground-level SO2 Concentrations Using Machine Learning Over East Asia)

  • 최현영;강유진;임정호
    • 대한원격탐사학회지
    • /
    • 제37권2호
    • /
    • pp.275-290
    • /
    • 2021
  • 대기 중의 이산화황(SO2)은 주로 인위적 배출원에 의해 발생하며 화학 반응을 통해 (초)미세먼지를 형성하여 직간접적으로 주변 환경 및 인체 건강에 해로운 영향을 주는 물질이다. 특히 지상에서의 농도는 인간 활동과 밀접한 관련이 있어 모니터링의 필요성이 매우 크다. 따라서, 본 연구에서는 TROPOMI SO2 연직 컬럼 농도 산출물 및 타 위성 산물과 모델 산출물 등을 융합 활용하여 기계학습 기법에 적용하여 SO2 지상 농도 추정모델을 개발하였다. 기계학습 기법으로는 널리 활용되고 있는 RF(Random Forest)에 잔차 보정 과정을 결합한 2-step 잔차 보정 RF를 적용하였다. 개발된 모델은 무작위, 공간 및 시간별 10-fold 교차 검증을 통하여 검증하였으며, 기울기(slope) 값이 1.14-1.25, 상관계수(R) 값이 0.55-0.65, rRMSE 값이 약 58-63% 정도로 나타났다. 이는 잔차 보정이 적용되지 않은 기존의 RF 대비 slope의 경우 약 10%, R과 rRMSE의 경우 약 3% 가량 향상된 결과를 보인다. 국가별로 나누어 분석하였을 때에는 샘플 수가 적고 SO2의 전반적인 농도가 낮은 일본 지역에서의 공간별 10-fold 교차검증 성능이 소폭 감소하는 것으로 나타났다. SO2 지상농도 분포를 계절별로 표출하였을 때, 일본의 경우 다른 지역 대비 연중 저농도가 관찰되며 높은 결측 값 비율로 인하여 관측소 농도 대비 2-step 잔차 보정 RF 모델에서 과대 모의하는 경향이 관찰되었다. 대표적 고농도 발생지인 중국의 YRD(Yangtze River Delta) 와 한국의 SMA(Seoul Metropolitan Area)의 계절적 분포 변화를 추가적으로 분석하였을 때, 연료 연소로 인한 겨울철 농도 증가 패턴이 나타났다. 이는 인위적 배출원의 영향을 크게 받는 SO2의 시공간적인 분포 특성을 잘 반영하고 있는 결과이다. 따라서, 본 연구를 통하여 제안한 모델은 장기적으로 SO2 지상 농도의 시공간적 분포를 파악하는 데에 활용될 수 있을 것으로 기대된다.

U.K. 지구시스템모델 UM의 리눅스 클러스터 설치와 성능 평가 (An Installation and Model Assessment of the UM, U.K. Earth System Model, in a Linux Cluster)

  • 윤대옥;송형규;박성수
    • 한국지구과학회지
    • /
    • 제43권6호
    • /
    • pp.691-711
    • /
    • 2022
  • 지구 대기에 영향을 주는 거의 모든 인간활동과 자연현상을 수치적으로 담아내는 지구시스템모델은 기후 위기의 시대에 활용될 가장 진보한 과학적 도구이다. 특히 우리나라 기상청이 도입한 지구시스템모델인 Unified Model (UM)은 지구 대기 연구의 과학적 도구로써 매우 활용성이 높다. 하지만 UM은 수치 적분과 자료 저장에 방대한 자원이 필요하여 개별 연구자들은 최근까지도 기상청 슈퍼컴퓨터에만 UM을 가동하는 상황이다. 외부와 차단된 기상청 슈퍼컴퓨터만을 이용하여 모델 연구를 수행하는 것은 UM을 이용한 모형 개선과 수치 실험의 원활한 수행에 있어 효율성이 떨어진다. 본 연구는 이러한 한계점을 극복할 수 있도록 개별 연구자가 보유한 고성능 병렬 컴퓨터(리눅스 클러스터) 에서 최신 버전 UM을 원활하게 설치하여 활용할 수 있도록 UM 시스템 환경 구축 과정과 UM 모델 설치 과정을 구체적으로 제시하였다. 또한 UM이 성공적으로 설치된 리눅스 클러스터 상에서 N96L85과 N48L70의 두 가지 모형 해상도에 대하여 UM 가동 성능을 평가하였다. 256코어를 사용하였을 때, 수평으로 1.875° ×1.25° (위도×경도)와 수직으로 약 85 km까지 85층 해상도를 가진 N96L85 해상도에 대한 UM의 AMIP과 CMIP 타입 한 달 적분 실험은 각각 169분과 205분이 소요되었다. 저해상도인 3.75° ×2.5° 와 70층 N48L70 해상도에 대해 AMIP 한달 적분은 252코어를 사용하여 33분이 소요되는 적분 성능을 보였다. 또한 적분을 위해 사용된 코어의 개수에 비례하여 적분 성능이 향상되었다. 성능 평가 외에 29년 간의 장기 적분을 수행하여 과거 지상 2-m 온도와 강수 강도를 ERA5 재분석자료와 비교하였고, 해상도에 따른 차이도 정성적으로 살펴보았다. 재분석자료와 비교할 때, 공간 분포가 유사하였고, 해상도와 대기-해양 접합에 따라 모의 결과에서 차이가 나타났다. 본 연구를 통해 슈퍼컴퓨터가 아닌 개별 연구자의 고성능 리눅스 클러스터 상에서도 UM이 성공적으로 구동됨을 확인하였다.

북동중국해 대륙붕 저서성 유공충 군집 분포와 형성 기작 (The Formation Mechanism and Distribution of Benthic Foraminiferal Assemblage in Continental Shelf of the northern East China Sea)

  • 정다운;이연규
    • 한국해양생명과학회지
    • /
    • 제8권1호
    • /
    • pp.8-31
    • /
    • 2023
  • 북동중국해 대륙붕 표층 퇴적물에서 산출하는 저서성 유공충의 군집 분포와 형성 기작을 파악하기 위하여 32개 정점에서 표층 퇴적물을 채취하고, 입도조성, 저서성 유공충 군집분석, 14C 연대측정을 실시하였다. 표층 퇴적물은 사질(평균: 52.04%)의 잔류 퇴적물과 니질(평균: 47.92%)의 현생 퇴적물과의 혼합 퇴적상이다. 저서성 유공충은 총 48속 104종(사질 유공충, 석회질 유리상 및 석회질 자기상 유공충)이 분류되었다. 사질 유공충은 양쯔강 앞 해역으로 산출빈도(30%)가 증가하며, 부유성 유공충은 제주 남서해역에서 높은 산출빈도를 보인다. 우점종은 Ammonia ketienziensis, Bolivina robusta, Eggella advena, Eilohedra nipponica, Pseudorotalia gaimardii, Pseudoparrella naraensis 총 6종이다. 이들 중 가장 높은 산출빈도를 보이는 Bolivina robusta와 Pseudorotalia gaimardii의 14C 연대측정 결과 각각 2,360±40 B.P., 2,450±40 B.P.로 나타났다. 군집분석 결과, P. gaimardii 군집, B. robusta 군집 및 A. ketienziensis-P. naraensis 군집으로 대별된다. 양쯔강 담수 유입 영향을 받는 양쯔강 앞 해역에는 P. gaimardii 군집, 쿠로시오 해류의 영향을 받는 제주도 남서해역에서 B. robusta 군집 그리고 북서측 황해 중앙부 니질대 해역에 A. ketienziensis-P. naraensis 군집이 분포한다. 이러한 저서성 유공충 군집 조성 및 분포는 약 2.5 ka BP 부터 형성되기 시작하였으며, 홀로세 후기 해수면 상승에 의한 저서 생태계 서식지 환경 변화를 반영하고 있는 것으로 생각된다.

뽕나무애바구미의 생태 및 방제에 관한 연구 (Studies on Biology and Control of the Mulberry Small Weevil, Baris deplanata ROELOFS (Coleoptera: Curculionidae))

  • 백현준;백운하
    • 한국잠사곤충학회지
    • /
    • 제18권2호
    • /
    • pp.65-78
    • /
    • 1976
  • 본 시험은 뽕나무애바구미의 외부형태, 생활사 및 약제방제법을 구명하기 위하여 실시하였다. 그 결과는 다음과 같다. 1. 성충은 칠흑색, 장정원형이고 주둥이는 길다. 암컷의 체장은 3.30$\pm$0.04mm, 폭 1.47$\pm$0.04mm, 주둥이 길이는 1.25$\pm$0.014mm이고 숫컷의 체장은 3.28% 0.06mm, 체폭 1.40$\pm$0.04mm, 주둥이 길이는 1.30$\pm$0.02mm이었다. 더듬이는 12절의 슬상이다. 숫컷의 복부는 끝이 뽀족하게 튀어 나왔고 암컷은 거의 일직선이다. 2. 난은 유백색의 장타원형이고 길이 0.51$\pm$0.05mm, 폭 0.32$\pm$0.02mm이었다. 3. 유충은 유백색, 원통형이며 두부는 농갈색이다. 다리는 없고 체장 3.88$\pm$0.06mm, 체폭 1.40$\pm$0.02mm이고 각절에는 많은 주름과 잔털이 있다. 4. 용은 장타원형 유백색이며 나용이다. 체장은 3.53$\pm$0.09mm. 체폭 1.40$\pm$0.03mm이었다. 5. 대부분 1년1세대이고 벌채후 남는 가지속에서 성충으로 월동하며 이듬해 4월하순에서 5월초순에 탈출한다. 그러나 일부 암컷은 당년에 탈출산난하며 유충(0.4%)이나 용(0.1%)으로 월동한다. 6. 난은 대부분 벌채후 남은 가지의 전피층에 산난하고 암컷의 평균 산난수는 73.44$\pm$8.74개이고 평균 산난일수는 33.88$\pm$6.04일이었다. 난기간은 11.69$\pm$0.39일, 유충기간은 45.04$\pm$1.63일, 용기간은 11.05$\pm$0.49일이었다. 성충의 잠복기는 약 270일이고 활동기간은 46.7$\pm$5.9일이었다. 7. 유충은 가지의 형성층을 먹고 성충은 동아, 잠복아, 엽병, 신초의 기부를 가해한다. 8. 성충의 발생소장은 춘벌유전에서는 5월초순에, 하벌유전에서는 6일 중순에 두면 peak를 나타냈다. 9. 유충밀도와 가지의 지름과 길이와는 정(+)의 상관을 이루었다. 10. 뽕나무애바구미의 가지당 성충의 분포는 부(-)의 이항분포를 이루였다. 11. 조사된 천적은 유충외부에 기생하는 좀벌이 발견되었고 이 좀벌의 기생률은 11.9%이었다. 12. Phosvel분제, Halir분제, Salithion유제, DDVP유제, Cidial 유제의 성충에 대한 방제효과가 우수하였고 핵충에 대해서는 Satchukoto-S유제, Salithion유제가 비교적 우수한 편이였다.

  • PDF

비대칭 헤드기어의 적용시 상악제 1 대구치에 나타나는힘과 변위 및 초기 응력분포에 관한 3차원 유한요소법적 연구 (A THREE-DIMENSIONAL FEM COMPARISON STUDY ABOUT THE FORCE, DISPLACEMENT AND INITIAL STRESS DISTRIBUTION ON THE MAXILLARY FIRST MOLARS BY THE APPLICATION OF VAR10US ASYMMETRIC HEAD-GEAR)

  • 김종수;차경석;주진원;이진우
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.25-38
    • /
    • 2001
  • 편측성 II급 부정 교합 환자를 만나는 것은 임상에서는 흔한 일이지만, 치료 방법은 제한적 인 것이 사실이다. 그 중에서도 asymmetric head-gear는 그 사용의 횟수에 비해 정확하고 완전한 이해가 부족한 실정이며, 효과를 극대화시키기 위한 장치의 디자인에 대한 정보 역시 아직도 논란이 많고, 그 동안의 연구들도 확실한 해답을 주지는 못하고 있다. 더욱이 asymmetric iace-bow를 유한요소법을 통해 해석한 것은 그 예를 찾아볼 수 없었기에 본 연구를 시행하게 되었다. 발치나 교정치료의 경험이 없는 정상교합자를 대상으로 유한요소법을 사용하여 편측성 II급 부정교합의 상악 치열궁을 모델링하고, RMO사의 Face-Bow($Penta-Form^{TM}$/Medium size)를 기본 모델로 오른쪽의 outer-bow가 15mm, 25mm, 35mm씩 짧은, 세 개의 asymmetric face-bow를 모델링한 후, 편측성 II급 부정교합 상악 치열궁 모델의 좌,우측 상악 제 1대구치에 세 종류의 asymmetric face-bow를 적용, 편측당 0.3kgf의 힘으로 견인하여 비교한 결과, 다음의 결론을 얻었다. 1. 양쪽 제 1 대구치가 받는 힘의 총합은 세 경우 모두에서 거의 차이가 없었으나, outer-bow의 길이가 짧아질수록 근심위치된 치아가 받는 힘의 크기는 증가하였고, 정상 위치된 치아가 받는 힘의 크기는 감소하는 결과를 보였다. 2. 양쪽 제 1 대구치가 받는 측방력은, 정상 위치된 치아에서는 outer-bow의 길이가 짧아질수록 협측으로의 힘이 커졌고, 근심 위치된 치아에서는 협측으로의 힘이 작아지는 경향을 보여, outer-bow의 길이가 짧아질수록 전체적인 측방력이 정상 위치된 치아의 협측으로 이동되는 경향을 보이긴 했지만, 양쪽 제 1 대구치 모두 협측으로 힘을 받는 것으로 나타나 "Archial Expansion Effect"를 보였다. 3. 양쪽 제 1 대구치가 받는 원심력과 정출력, 그리고 distal tipping의 양은, 정상 위치된 치아에서는 outer-bow의 길이가 짧아질수록 감소하였고, 근심 위치된 치아에서는 outer-bow의 길이가 짧아질수록 증가하는 경향을 보였다. 4. 양쪽 제 1 대구치의 rotation은, 정상 위치된 치아에서는 distal-in의 rotation을 보였으며 outer-bow의 길이가 짧아질수록 그 양이 증가하였고, 근심 위치된 치아에서는 두 가지의 결과를 나타냈는데, outer-bow가 15mm 짧은 경우에는 distal-in의 rotation을 보였으나, 25mm와 35mm 짧은 경우에는 distal-out의 rotation을 보여 15mm와 25mm 사이에 변환점이 존재하는 것으로 나타났다. 5. 치근 분지부 직하방에서 치근막의 초기 응력분포를 관찰한 결과, 정상 위치된 치아의 원심협측 치근에서 outer-bow의 길이가 짧아짐에 따라 압축응력이 구개측에서 원심측으로, 그리고 협측으로 이동하는 양상을 나타내었다. 6. 치근 분지부 직하방에서 치근막의 초기 응력분포를 관찰한 결과, 정상 위치된 치아의 원심협측 치근을 제외한 근심협측 치근과 구개측 치근, 그리고 근심 위치된 치아의 세 개의 치근 모두는, outer-bow의 길이가 짧아질수록 응력의 크기만 변할 뿐 전체적인 응력분포의 양상에는 변화가 없었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF