• Title/Summary/Keyword: Size and Location

Search Result 2,378, Processing Time 0.027 seconds

Effect of orientation, interval size, target location on interpolation estimates on CRT display. (CRT 표시장치에서 내삽 추정치에 대한 방향, 크기, 위치의 효과)

  • 노재호
    • Journal of the Ergonomics Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1990
  • This study is concerned with the accuracy, of error with which subjects can interpolate the location of a target between two graduation markers with 4 orientations and 6 sizes CRT display. Stimuli were graphic images on CRT with a linear, end-markec, ungraduated scales having a target. The location of a target is estimated in units over te range 1-99. Smallest error of estimates was at the near ends and middle of the base-line. The median error was less than 2 units, modal error was 1, and the most error (; 99.7%) was within 10. A proper size to make an minimum error in interpolation exists such that size 400 pixels. Interpolation estimation is shown to be affected by the size, location and interaction (orientation x location, size x location). The accuracy, interpolation performance are discussed in relation to absolute error associated with visual performance.

  • PDF

The Transportation Size and the Location of Distribution Centers in a Distribution System (물류시스템에서 수송크기와 물류센터의 위치)

  • Chang, Suk-Hwa
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.3
    • /
    • pp.12-19
    • /
    • 2007
  • This paper is to determine the transportation size and the location of distribution centers to minimize logistics cost in a distribution system where products are transported from the distribution centers to the retailers. Logistics cost consists of the fixed cost of distribution centers, the transportation cost from the distribution centers to the retailers and the inventory holding cost in the retailers. The logistics cost is affected by the transportation size and the location of distribution centers. The transportation size affects transportation cost and inventory holding cost. The location of distribution centers affects the transportation cost. A mathematical model is formulated and the algorithm is developed. A numerical example is shown to explain the problem.

The Study on the Size of the Registration Database for Location Registration Area in Mobile Communication Networks (이동통신망에서의 위치등록 데이타베이스 크기에 대한 연구)

  • Park, Jeong-Hoon
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.81-85
    • /
    • 1998
  • Location Registration and deregistration is necessary to mobility management in a Mobile Communication networks when a mobile phone moves between location registration areas. After considering several deregistration schemes, a sample scheme that eliminate network traffic is chosen. However, this scheme may delete valid registration record, so the size of location registration database must be sufficiently large to ensure low probability that a valid records are deleted. This paper describes an analytic model to determine the size of location registration database for a location registration area in this simple scheme. The simulation results of analytic model show that the size of database must 3-5 times than the expected number of mobile phones in a location registration area.(Mobile, Communications, Location, Deregistration, Database)

  • PDF

Distribution Characteristics of 3,369 Chinese Colorectal Cancer Patients for Gender, Age, Location and Tumor Size During Colonoscopy

  • Cai, Bin;Wang, Mu-Yong;Liao, Kai;Xu, Yan-Song;Wei, Wei-Yuan;Zhuang, Yuan;Zhang, Sen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8951-8955
    • /
    • 2014
  • Background: Studies have shown the existence of gender- and age-related differences in the incidence and anatomic distribution of colorectal cancers. The purposes of this study were to analyze the distribution characteristics of colorectal cancer patients regarding gender, age, location and tumor size in the course of colonoscopy. Materials and Methods: All colorectal cancer patients who underwent colonoscopy in the First Affiliated Hospital of Guangxi Medical University from 2003 to 2012 were included in our retrospective study. Demographic information (age and gender) and colonoscopy report information (tumor size and location) were collected and analyzed. To compare the gender differences in tumor location and tumor size, as well as the size differences in tumor location, the chi-square test was used. Results: A total of 3, 369 colorectal cancer patients (2, 007 men vs 1, 362 women) were included in our study. Statistical analysis showed there was no gender difference in the anatomic distribution of the tumors (p>0.05). However, there was a gender difference in tumor size (p<0.05). In addition, our study found there was a significant difference in tumor size between rectal and colon tumors (p<0.001). Conclusions: There was no gender difference in the anatomic distribution of colorectal tumors. In addition, tumors observed in men were larger than in women.

Selection of Optimal Location and Size of Distributed Generation Considering Power Loss (전력손실을 고려한 분산전원의 최적 위치 및 용량 선정)

  • Lee, Soo-Hyoung;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.551-559
    • /
    • 2008
  • Increase in power consumption can cause a serious stability problem of an electric power system without construction of new power plants or transmission lines. Also, it can generate large power loss of the system. In costly and environmentally effective manner to avoid constructing the new infrastructures such as power plants and transmission lines, etc, the distributed generation(DG) has paid great attentions so far as a solution for the above problem. Selection of optimal location and size of the DG is the necessary process to maintain the stability and reliability of existing system effectively. However, the systematic and cardinal rule for this issue is still open question. In this paper, the method to determine optimal location of the DG is proposed by considering power loss when the DG is connected to an electric power grid. Also, optimal size of not only the corresponding single DG but also the multi-DGs is determined with the proposed systematic approach. The IEEE benchmark 30-bus test system is analyzed to evaluate the feasibility and effectiveness of the proposed method.

A robust identification of single crack location and size only based on pulsations of the cracked system

  • Sinou, Jean-Jacques
    • Structural Engineering and Mechanics
    • /
    • v.25 no.6
    • /
    • pp.691-716
    • /
    • 2007
  • The purpose of the present work is to establish a method for predicting the location and depth of a crack in a circular cross section beam by only considering the frequencies of the cracked beam. An accurate knowledge of the material properties is not required. The crack location and size is identified by finding the point of intersection of pulsation ratio contour lines of lower vertical and horizontal modes. This process is presented and numerically validated in the case of a simply supported beam with various crack locations and sizes. If the beam has structural symmetry, the identification of crack location is performed by adding an off-center placed mass to the simply supported beam. In order to avoid worse diagnostic, it was demonstrated that a robust identification of crack size and location is possible if two tests are undertaken by adding the mass at the left and then right end of the simply supported beam. Finally, the pulsation ratio contour lines method is generalized in order to be extended to the case of rectangular cross section beams or more complex structures.

Evaluation of Radiation Dose according to Aneurysm Size and Location during Cerebral Aneurysm Coil Embolization (뇌동맥류 코일 색전술 시술 시 동맥류 크기 및 위치에 따른 방사선량 평가)

  • An, Hyun
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.407-412
    • /
    • 2022
  • Cerebral aneurysm coil embolization has the advantages of accurate, low patient burden, and fast recovery time, but efforts are needed to reduce dose due to the burden of exposure radiation dose during interventional procedures. In this study, the area dose product(DAP/Gy·cm2) and fluoro time(min) according to the size of the aneurysm and the location of aneurysm were investigated according to insurance recognition regulations aneurysm classification cerebral aneurysm coil embolization. According to the research method, classification according to the size and location of the aneurysm is first, the size of the aneurysm is divided into less than 4mm, more than 4mm to less than 8mm, and more than 8mm, and second, the dose to the area based on the location site (DAP/Gy·cm2) and fluoro time(min) based on the location site were observed. As a result, the location of the cerebral aneurysm procedure was found to be the Paraclinoid site. During cerebral aneurysm coil embolization, the area dose was 107 Gy·cm2 and fluoro time was 47.41 minutes, showing lower results than domestic studies, and when comparing the area dose product with foreign studies, the area dose product results were similar to that of Turkey and Saudi Arabia. It is expected that it can be used as an objective analysis indicator to establish diagnostic reference levels (DRLs) and patient radiation defense guidelines according to the size of cerebral aneurysm and location of cerebral aneurysm procedures during interventional procedures.

Effect of Interval Size on Interpolation Estimates between Graduation Markers on CRT Display (CRT 표시장치에서 내삽 추정치에 대한 구간크기의 효과)

  • Ro, Jae-Ho
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.67-77
    • /
    • 1989
  • This study is concerned with the accuracy, the pattern of error with which subjects can interpolate the location of a pointer or a target between two graduation markers with various size on CRT display. Stimuli were graphic images on CRT with a linear, end-marked, ungraduated scales having a target for t base-line sizes. The location of a target is estimated in units over the range 1-99. Smallest error of estimates was at the near ends and middle of the base-line. The median error was less 2 units, modal error was 1, and most error(;99.6%) was within 10. Subjects had a more tendency to overestimate than to underestimate at the left-part of base-line in all siges, and an opposite tendency at the right-part. A proper size to minimize the interpolation error exists such that size 500. It is suggested that interpolation of fifths and even tenths will give a reguired accuracy for certain situations, and relative location and base-line size has a relevant attribute to interpolate.

  • PDF

A Primary Study on the Location and Size of Railway Station Facilities (철도 역시설의 입지와 규모에 관한 기초 연구)

  • 문대섭;이경철;정병현
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.116-121
    • /
    • 2002
  • This primary study has some bounds md limits owing to the descriptive reviews but not detailed analyses. However, 1 tried to do the comparative analyses and case studies about location and size of rail station for future efficient use of spatial structure. Therefore, I reviewed the location of railway station and some design standards of railway station facilities by type (high speed rail, conventional rail and urban rail), and also, suggested future direction for rail station as the core of city development relating with urban structures and human settlement system reformation.

  • PDF

Evaluation of characteristics of drainage layer according to particle size, particle size, and compositional location of aggregate using fluid analysis program (유체해석 프로그램을 이용한 골재의 입자크기 및 입도, 구성위치에 따른 배수층의 특성 평가)

  • Lim, Chang-Min;Kwon, Hyun-Woo;Kim, Young-Min;Cho, Do-Young;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.147-148
    • /
    • 2022
  • Due to recent climate abnormalities, the form of rainfall is changing to localized torrential rains. Localized torrential rains cause flooding in urban areas. In addition, in various industrial fields, there are cases where materials necessary for the process are kept outdoors, and damage from material loss and flooding of stockyards occurs during heavy rain. Accordingly, it is necessary to introduce a drainage layer where flooding is expected. This drainage layer places the aggregate inside and allows rainwater to penetrate and drain into the voids between the aggregates. However, the amount of voids differs according to the particle size distribution and particle size of the aggregate, and the drainage performance varies according to the compositional location of the aggregate. Therefore, in this study, the drainage characteristics according to the particle size, particle size, and compositional location of aggregates are analyzed using a fluid analysis program.

  • PDF