• Title/Summary/Keyword: Size Distribution

Search Result 7,785, Processing Time 0.039 seconds

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

Density Effects on the Size of 2-1 Korean Pine and 1-1 Jack Pine Nursery Stock (잣나무 2-1 묘(苗)와 방크스소나무 1-1 묘(苗)의 생장(生長)에 미치는 밀도효과(密度効果))

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 1976
  • One of the most common needle leaf species used in planting in Korea is korean pine (Pinus koraiensis S. et Z.), and jack pine (Pinus banksiana Lamb.) is one of the test species for suitability. The relation of nursery bed density of 2-1 korean pine and 1-1 jack pine was studied at the Kwang Nung Nursery, Central Branch Station of Forest Research Institute, and about 40km north of Seoul. Nursery bed density of 2-1 korean pine, which ranged from 36 to 324 trees per square meters and of 1-1 jack pine, which ranged from 25 to 169 trees per square meters, had a marked effect on caliper, height, dry weight and percent and amount of plantable stock. The soil physical and chemical properties is silt plus clay, 50.55 percent; organic matter, 2.09 percent; total nitrogen, 0.13 percent; available phosphorus, 253.25 ppm; exchangeable potash, 0.46 m.e/100g; and pH, 5.58. As the density of the nursery seedling stand of 2-1 korean pine increases, the average tree height increases (Fig. 1A), but in 1-1 jack pine density do not affect to increase or decrease the average tree height. As the density of nursery bed increases, the average stem caliper (at 2cm above ground line) and dry weight decrease (Fig. 1B), but the decreasing rate is more seriously in 1-1 jack pine than 2-1 korean pine (Fig.5). As increasing the density of nursery bed, the T/R ratio of trees of the test species increase. Also the dry weight of leaf, stem and root parts are decreasing in proportion to the increase of stand density, but the drop rate of jack pine is more rapid than korean pine (table. 1) The patent facts of difference of growth characteristics between 2-1 korean pine and 1-1 jack pine were studied. These facts should be used to select the scale of stand density at the nursery bed or the plantable site. Korean pine is demanded high density, on the other hand in jack pine low density are more suitable to manage the stand density. Stands of comparatively low density had the greatest percentage of high-quality stock, and the stands of high density had less than the high quality trees of low density. An important criterion of the best density is percent and number of high-quality trees produced per square meter of bed area. Stem caliper and stem height of seedling is used in most public nurseries to sort seedling into plantable grades. The stock grade standard has set at 4.5mm caliper and 16cm height of 2-1 korean pine as the minimum desired stem caliper and height. By the result studies, the plantable stock grade standards of 2-1 korean pine used at stem height 16cm and stem caliper 4.5mm from public nurseries should be reformed to stem height 18cm and stem caliper 4.0mm by the growth characteristics and the tree distribution of stem height and caliper of relation to density. For the 2-1 korean pine, best density should be about 160 to 200 trees per square meter according to soil fertility. For the 1-1 jack pine, the suitable standard of plantable stock should be at stem height 25cm and caliper 6mm (at 2cm above ground line) and best density was about 100 to 120 trees.

  • PDF

Quality Characteristics of Adzuki Beans Sediment According to Variety (품종에 따른 팥 앙금의 품질 특성)

  • Song, Seuk-Bo;Seo, Hye-In;Ko, Jee-Yeon;Lee, Jae-Saeng;Kang, Jong-Rae;Oh, Byeong-Geun;Seo, Myung-Chul;Yoon, Young-Nam;Kwak, Do-Yeon;Nam, Min-Hee;Woo, Koan-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1121-1127
    • /
    • 2011
  • We evaluated the quality characteristics of adzuki bean sediment according to variety. The moisture, crude protein, and crude ash contents of the various adzuki bean varieties were 8.2~11.1, 15.4~20.6 and 3.3~3.6 g/100 g, respectively. The potassium contents of Chilbo-pat (CB) and Hongeon-pat (HE) were 875.1 and 873.1 mg/100 g, respectively. The calcium contents of Jungbu-pat (JB) and Kumsil-pat (KS)were 73.6 and 73.2 mg/100 g, respectively. A high level of magnesium (131.4 mg/100 g) was found in Yeonkeum-pat (YK). The yields of adzuki bean sediment according to variety were no different either wet (188.3~204.7%) or dry (62.1~66.0%). The L-values on sediment of YK and KS were 67.0 and 68.0, respectively; however, the CB L-value was low at 54.0. A high level of a- (6.6) and b-value (12.8) was found in YK; however, the values for CB were much lower at 3.8 and 5.9, respectively. There was no difference in particle-size distribution, water binding capacity, and solubility of adzuki bean sediment according to variety. High levels of peak (3.79 RVU), trough (3.75 RVU), final (7.33 RVU), and setback viscosity (3.54 RVU) were found in JB. The sensory properties of products in food processing are important, and the variety of adzuki bean sediment should be chosen depending on desired product characteristics.

Physical Properties of Pericarp in a Walnut Cultivar, 'Yongdong' (호도나무 '영동' 품종 과피의 물리적 특성)

  • Lee, Uk;Lee, Moon-Ho;Byun, Kwang-Ok;Jung, Myung-Suk
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.4
    • /
    • pp.455-461
    • /
    • 2007
  • This research was processed on morphological and physical characteristics of 'Yongdong' cultivar nuts. (1)Morphological properties of 'Yongdong' cultivar nuts were significantly different from the control, native species, in respect of all properties. (2) 'Yongdong' cultivar nuts showed higher figures than the native species on 9 items of morphological properties (kernel weight, size, length and width of pad on suture and etc.), whereas other 6 items (height of pad on suture, thickness of shell and septem, fragment numbers of isolated kernel, roundness index, and etc.) showed lower figures than those of the control. (3) In physical properties of the nut shells, 'Yongdong' cultivar was superior to the control at all items with the exception of compressive prove distance. Accordingly, it was also verified as effective cultivar of shelled walnut with suture line direction applied the minimum strength. (4) 'Yongdong' cultivar, 21.9 kg, was approximately twice lower than the control, 42.6 kg, on maximum compressive weight. It was demonstrated that the 'Yongdong' cultivar characterized by easily crushing shell by small strength was great in cracking properties. (5) On the study of yield strength, the native species being twice higher than 'Yongdong' cultivar showed the properties of the small elasticity and the shell hardness. While, the suture line of 'Yongdong' cultivar having the lowest yield strength 15.6 kg and 16.0 kg was identified the shell crushed easily. (6) The movement distance of the compressive prove of 'Yongdong' cultivar, 4.2 mm, was longer than that of the control, 2.7 mm. Subsequently, it means that the amount of loss possibly occurring to distribution process was not great, whereby productive value was high. (7) The compressive strength of the suture line of 'Yongdong' cultivar, $9.1kg/cm^2$, was much lower than total average of that $12.4kg/cm^2$. It was also statistically different with other properties. (8)The hardness examination by the compressive position revealed that the suture line of 'Yongdong' cultivar, $149.8kg/cm^2$, was lowest in contrast with the control, $300.9kg/cm^2$.

A Feasibility Study on the Use of Liner and Cover Materials Using Sewage Sludge (하수슬러지의 차수재 및 복토재로의 이용타당성에 관한 연구)

  • 유남재;김영길;박병수;정하익
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.2
    • /
    • pp.43-71
    • /
    • 1999
  • This research is an experimental work of developing a construction material using municipal wastewater sludge as liner and cover materials for waste disposal landfill. Weathered granite soil and flyash, produced as a by-product in the power plant, were used as the primary additives to improve geotechnical engineering properties of sludge. For secondary additives, bentonite and cement were mixed with sludge to decrease the permeability and to increase the shear strength, respectively. Various laboratory test required to evaluate the design criteria for liner and cover materials, were carried out by changing the mixing ratio of sludge with the additives. Basic soil properties such as specific gravity, grain size distribution, liquid and plastic limits were measured to analyze their effects on permeability, compaction, compressibility and shear strength properties of mixtures. Laboratory compaction tests were conducted to find the maximum dry densities and the optimum moisture contents of mixtures, and their effectiveness of compaction in field was consequently evaluated. Permeability tests of variable heads with compacted samples, and the stress-controlled consolidation tests with measuring permeabilities of samples during consolidation process were performed to obtain permeability, and to find the compressibility as well as consolidational coefficients of mixtures, respectively. To evaluate the long term stability of sludges, creep tests were also conducted in parallel with permeability tests of variable heads. On the other hand, for the compacted sludge decomposed for a month, permeability tests were carried out to investigate the effect of decomposition of organic matters in sludges on its permeability. Direct shear tests were performed to evaluate the shear strength parameters of mixed sludge with weathered granite, flyash and bentonite. For the mixture of sludge with cement, unconfined compression tests were carried out to find their strength with varying mixing ratio and curing time. On the other hand, CBR tests for compacted specimen were also conducted to evaluate the trafficability of mixtures. Various test results with mixtures were assessed to evaluate whether their properties meet the requirements as liner and cover materials in waste disposal landfill.

  • PDF

A study on urban heat islands over the metropolitan Seoul area, using satellite images (원격탐사기법에 의한 도시열섬 연구)

  • ;Lee, Hyoun-Young
    • Journal of the Korean Geographical Society
    • /
    • v.40
    • /
    • pp.1-13
    • /
    • 1989
  • The brightness temperature from NOAA AVHRR CH 4 images was examined for the metropolitan Seoul area, the capital city of Korea, to detect the characteristics of the urban heat island for this study. Surface data from 21 meteorological stations were compared with the brightness temperatures Through computer enhancement techniques, more than 20 heat islands could be recognized in South Korea, with 1 km spatii resolution at a scale of 1: 200, 00O(Fig. 3, 4 and 6). The result of the analysis of AVHRR CH 4 images over the metropolitan Seoul area can be summerized as follows (1) The pattern of brightness temperature distribution in the metropolitan Seoul area shows a relatively strong temperature contrast between urban and rural areas. There is some indication of the warm brightness temperature zone characterrizing built-up area including CBD, densely populated residential district and industrial zone. The cool brightness temperature is asociaed with the major hills such as Bukhan-san, Nam-san and Kwanak-san or with the major water bodies such as Han-gang, and reservoirs. Although the influence of the river and reservoirs is obvious in the brightness temperauture, that of small-scaled land use features such as parks in the cities is not features such as parks in the cities is not apperent. (2) One can find a linerar relationshop between the brightenss temperature and air temperature for 10 major cities, where the difference between two variables is larger in big cities. Though the coefficient value is 0.82, one can estimate that factors of the heat islands can not be explained only by the size of the cities. The magnitude of the horizontal brightness temperature differences between urban and rural area is found to be greater than that of horizontal air temperature difference in Korea. (3) Also one can find the high heat island intensity in some smaller cities such as Changwon(won(Tu-r=9.0$^{\circ}$C) and Po-hang(Tu-r==7.1$^{\circ}$~)T. he industrial location quotient of Chang-won is the second in the country and Po-hang the third. (4) A comparision of the enhanced thermal infrared imageries in 1986 and 1989, with the map at a scale of 1:200, 000 for the meotropolitan Seoul area showes the extent of possible urbanization changes. In the last three years, the heat islands have been extended in area. zone characterrizing built-up area including (5) Although the overall data base is small, the data in Fig. 3 suggest that brightness tempeautre could ge utilized for the study on the heat island characteristics. Satellite observations are required to study and monitor the impact of urban heat island on the climate and environment on global scale. This type of remote sensing provides a meams of monitoring the growth of urban and suburban aeas and its impact on the environment.

  • PDF

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

Geophysical and Geological Investigation for Selecting a Dinosaur Museum Site in the Dinosaur Egg Fossil Area, Gojeong-ri, Hwasung, Gyeonggi Province (경기도 화성 고정리 공룡알 화석지 공룡생태박물관 부지선정을 위한 지구물리 및 지질조사)

  • Kim, Han-Joon;Jeong, Gap-Sik;Yi, Bo-Yeon;Jo, Churl-Hyun;Lee, Kwang-Bae;Lee, Jun-Ho;Jou, Hyeong-Tae;Lee, Gwang-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.357-363
    • /
    • 2010
  • In this study, we investigated the geologic structure of the basement and overlying sediments of the construction site of the dinosaur egg fossil museum in Hwasung, Gyeonggi Province through refraction seismology, drilling, and downward seismic velocity measurements in the drill holes. The construction site ($350{\times}750\;m^2$) is located in the reclaimed area south of Sihwa Lake, Gojeong-ri. About 6,950 m of seismic refraction data consisting of 11 lines were acquired using a sledge hammer source. Drilling to the basement was performed at five sites. Sediment samples from drilling were analysed for grain-size distribution and age dating. At two drill holes, seismic velocity was measured with depth using a hammer as a seismic source. The geological structure of the study area consists of, from top to bottom, a tidal flat layer (5 ~ 12 m thick), a weathered soil layer (2 ~ 8 m thick), and the basement. The basement is interpreted as Cretaceous sedimentary rocks that tend to be shallow eastward. The volume of the tidal flat sediments and weathered soil in the study area is estimated as $1.4{\times}10^6\;m^3$, weighing $3.5{\times}10^6$ tons. The rate of sea level rise since 8,000 yrs BP is estimated to be 0.1 ~ 0.15 cm/yr.

Epidermal Structure and Stomatal Types in Some Species of Korean Crassulaceae (한국산 돌나물과(Crassulaceae) 수종의 표피구조와 기공유형)

  • Jeong, Woo-Gyu;Sung, Min-Wung
    • Journal of Plant Biology
    • /
    • v.28 no.2
    • /
    • pp.105-118
    • /
    • 1985
  • This study was carried out to investigate the epidermal structure and types of stomata on the upper and lower surfaces of the leaves in six species and one variety belonging to Korean Crassulaceae. The shape of epidermal cells was polygonal, isodiametric, or elongated. The cell wall was thick, sinuous or deeply sinuous. The subsidiary cell wall was thin or mostly arched. The cytolith-containing cells were found in Orostachys japonicus. The distribution of stomata was more on the upper surface than on the lower surface in the leaves of O. japonicus and Sedum sarmentosum. The stomata in the other species were less on the upper surface than on the lower surface, and stomatal size was different in each species. The great majority of stomatal types was the helico-eumesogenous type. This type was subdivided into two, parahelico-eumesogenous type and diahelico-eumesogenous type by us on the basis of the angle of division of guard mother cell and the long axis of the last-formed subsidiary cells. Sometimes allelo-eumesogenous type as well as aniso-eumesogenous type was found. The tetra-eumesogenous type with four mesogenous subsidiary cells was rarely observed. It was observed that the varieties of aniso-eumesogenous type with one to three subsidiary cells and one helix of subsidiary cells were developed by the secondary division of subsidiary cells of aniso-eumesogenous stoma. The compound shape of helico-eumesogenous stomata was found. Five new kinds of stomatal types were observed as follows; the helico-tetra-eumesogenous type, the coallelohelico-eumesogenous type, the cohelico-allelo-eumesogenous type, the duplotetra-eumesogenous type, and the aniso-euperigenous type. These types were reported here in the vascular plants for the first time.

  • PDF

Classification of the Family Congridae(Anguilliformes) from Korea (한국산(韓國産) 붕장어과(科)(뱀장어목(目)) 어류(魚類)의 분류(分類))

  • Lee, Chung-Lyul;Park, Mi-Hye
    • Korean Journal of Ichthyology
    • /
    • v.6 no.2
    • /
    • pp.132-159
    • /
    • 1994
  • The taxonomic revision of the family Congridae was made based on the specimens collected from the south-western coasts of the Korea from June 1988 to Oct. 1993. The family Congridae was classified into 8 species belonging to 6 genera. based on the external and internal morphological characters : Anago anago, Ariosoma anagodies, Ariosoma shiroanago shiroanago, Conger myriaster, Conger japonicus, Gnathophis nystromi nystromi, Rhechias retrotincta and Uroconger lepturus. Among the species reported as the congrid eels from Korea until now, four species were transferred into different generic or specific name Conger flavirostris into Ariosoma anagoides ; Astroconger myriaster into Conger myriaster ; Congrina retrotincta into Rhechias retrotincta and Rhynchocymba nystromi into Gnathophis nystromi nystromi. A Korean congrid eel, Ariosoma shiroanago shiroanago, was reported for first time in Korea. Intergeneric characters of the family Congridae were the form of the lateralline scales, the state of the tip of tail, the segmented state of the dorsal and anal fin rays, the existance of the supraoccipital bone and of lateral ethmoid process of the skull, the origin of dorsal fin and the forms of upper labial flange. The interspecific classification was made according to the characters such as the numbers of sensory pores of head part and in front of vent, teeth rows and numbers of upper and lower jaw, the numbers of vertebrae, the body color, the shapes of the head part, the color of intestine, the size of eye, the structure of air bladder and the number of branchiostegal rays. A new key on the taxonomical characteristics to the genera and species of the family Congridae has been estabilished and their distribution in Korea is described.

  • PDF