• Title/Summary/Keyword: Site amplification

Search Result 214, Processing Time 0.021 seconds

A Comparative Study of Microtremor HVSR from the Surface and Downhole Seismometers (지표형과 지중형 지진계의 상시미동 자료를 이용한 HVSR 비교 연구)

  • Su Young Kang;Kwang-Hee Kim
    • Journal of the Korean earth science society
    • /
    • v.44 no.6
    • /
    • pp.594-610
    • /
    • 2023
  • The horizontal-to-vertical spectral ratio (HVSR) has been widely applied to evaluate ground characteristics such as site response and thickness of the soft sedimentary layer on top of the bedrock via dominant frequencies and amplification factors of microtremors. Eight seismic stations were selected to investigate the HVSR results at the surface and at varying depths, and their variations due to wind speeds. These stations are equipped with seismic sensors on the surface and downhole(s) at depths. The borehole data analysis reveals that the geological condition at burial depth influences the HVSR results. Their dominant frequencies indicate the entire thickness of the soft layer, not the thickness to the bottom or top of the soft sedimentary layer from the seismometer burial depth. Analysis of the background noise observed at the surface showed that the resonance frequency estimation varied with wind speed changes. In the studied cases, the background noise observed in the sedimentary layer at depths of 20 to 66 meters yielded stable and consistent resonance frequency estimation regardless of wind speed fluctuations. The results of the seismic sensors buried deeper than 100 meters are unstable. The result indicates that the background noise from the buried seismometer at shallow depths (~0.3 m) under light wind conditions (wind speeds less than 3 m/s) is sufficient to achieve the purpose of the HVSR analysis.

MOLECULAR BIOLOGIC ANALYSIS OF FMR-1 GENE TRINUCLEOTIDE REPEATS IN AUTISTIC PATIENTS (자폐장애 환자에서 FMR-1 유전 삼염기 반복의 분자생물학적 분석)

  • Kwak, Ho-Soon;Chun, Hyo-Jin;Chang, Eun-Jin;Kim, Hee-Cheol;Kim, Jung-Bun;Park, Young-Nam;Jung, Chul-Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.3-15
    • /
    • 2000
  • Objectives:There has been a rapid expansion of studies aimed at elucidating the genetic basis of autistic disorder, especially it’ relationship to fragile-X syndrome. The detection of fragile X chromosome(Xq27.3) by cytogenetic analysis has revealed many difficulties in testing. Therefore, to explore the relationship between autistic disorder and fragile X syndrome, this study administered molecular biologic methods which examined an unstable CGG repeat within the fragile X mental retardation-1(FMR-1) gene. Methods:Ninety nine autistic children and eight normal control children were tested. The number of CGG repeats within FMR-1 gene was measured after amplification by PCR, and cytogenetic analysis was also carried out to detect fragile site Xq27.3. Southern blot hybridization, using StB12.3 and/or Pfxa3 probe, was done for the patients showing expansion of more than 50 CGG repeats (premutation). Results:All but two autistic patients had no expansion in CGG repeats by PCR and there was no significant statistical difference in number of CGG repeat in comparison with normal control. Two autistic patients, considered as premutation by PCR analysis, had no full mutation or premutation by Southern blot hybridization. All autistic children tested did not have any abnormal karyotype or fragile site Xq27.3. Conclusions:These results suggest that autistic patients may not have abnormality in FMR-1 gene or abnormal expansion in CGG repeat. In conclusion, fragile X syndrome may not be antecedent of autistic disorder.

  • PDF

The Study of DNA Mutations of Phenylketonuria in Koreans (한국인에서의 페닐케톤뇨증의 유전자변이에 대한 고찰)

  • Yoo, Su-Jung;Hong, Yong-Hee;Lee, Yong-Wha;Jung, Sung-Chul;Ki, Chang-Seok;Lee, Dong-Hwan
    • Journal of Genetic Medicine
    • /
    • v.5 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • Purpose : Phenylketonuria(PKU) is an inborn error of metabolism and a genetic disorder resulting from a deficiency of phenylalanine hydroxylase(PAH) and decreased activity of tetrahydrobiopterin(BH4).In this study the correlation between the DNA mutation and clinical manifestations was investigated and PAH DNA mutations were compared bewteen Asian and Caucasian populations. Methods : DNA was isolated from peripheral leukocytes. The PAH gene was amplified by Polymerase Chain Reaction(PCR) and the sequence was analyzed with Multiplex Ligation-dependent Probe Amplification(MLPA). Results : We characterized the PAH gene of 102 independent Korean patients with PKU. PAH nucleotide sequence analysis revealed 44 different mutations, including 10 novel mutations comprising 9 missense mutations(N207D, K95del, A447P, G344D, P69S, S391I, A202T, G103S, and I306L) and 1 novel splice-site variant mutation(IVS10-3C>G). R243Q was the most prevalent mutation in this study. A259T has not previously been reported in Asian populations, but we found that this mutation had a frequency of 10.1% in our study. Furthermore, the genotypes of $BH_4$ responsive patients were analyzed and were divided into two groups: $BH_4$ medication-only group and $BH_4$ medication with diet therapy group. In the $BH_4$ medication-only group and $BH_4$ medication with diet therapy group, R241C was the most common mutation. Conclusion : Novel mutations in the PAH gene of PKU patients are still being discovered. Additional information as to the frequency of mutations in the tetrahydrobiopterine responsive gene is also accumulating. We anticipate that knowledge of these PKU gene mutations will assist the diagnosis, genetic counseling, and therapeutic treatment of PKU patients in future.

  • PDF

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.