• Title/Summary/Keyword: Sinus floor elevation

Search Result 62, Processing Time 0.016 seconds

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.

Methemoglobinemia caused by a low dose of prilocaine during general anesthesia

  • Shibuya, Makiko;Hojo, Takayuki;Hase, Yuri;Kimura, Yukifumi;Fujisawa, Toshiaki
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.357-361
    • /
    • 2021
  • Methemoglobinemia is a blood disorder in which an abnormal amount of methemoglobin is produced, and prilocaine is one of the drugs that can cause this disorder. The maximum recommended dose of prilocaine is 8 mg/kg. We report a case of methemoglobinemia caused by the administration of 4.2 mg/kg of prilocaine without other methemoglobinemia-inducing drugs during general anesthesia. A 17-year-old girl with hyperthyroidism and anemia was scheduled to undergo maxillary sinus floor elevation and tooth extraction. The patient's peripheral oxygen saturation (SpO2) decreased from 100% at arrival to 95% after receiving prilocaine with felypressin following induction of general anesthesia. However, the fraction of inspired oxygen was 0.6. Blood gas analysis showed that the methemoglobin level was 3.8% (normal level, 1%-2%), fractional oxygen saturation was 93.9%, partial pressure of oxygen was 327 mmHg, and arterial oxygen saturation was 97.6%. After administration of 1 mg/kg of methylene blue, her SpO2 improved gradually to 99%, and the methemoglobin value decreased to 1.2%. When using prilocaine as a local anesthetic, it is important to be aware that methemoglobinemia may occur even at doses much lower than the maximum recommended dose.