• 제목/요약/키워드: Sinus elevation

검색결과 103건 처리시간 0.022초

상악동 거상술을 동반한 임플란트 식립 후 생존율에 대한 후향적 연구 (The retrospective study of survival rate of implants with maxillary sinus floor elevation)

  • 유정아;이상민;유미경;정의원;김창성;최성호;박필규;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제39권3호
    • /
    • pp.293-301
    • /
    • 2009
  • Purpose: The purpose of this study is to show the total survival rate of implants with maxillary sinus floor elevation and the effects that reach the survival rate by classifying types of graft materials, implant surface, operation method, bone height. Methods: In a total of 131 patients, 251 implants with sinus floor elevation were installed simultaneously or after regular healing. Various bone grafts (autograft, xonograft, allograft, alloplast) and implant surface (MTX-HA implant, chemical etching implant, Titanium oxide surface implant, resorbable blasting media implant, resorbable blast texturing implant, HA-coated implant) were used. All implants were investigated clinically and radiographically, being with 1 to 5 years follow-up period after installation. Results: The survival rate of 251 implants with maxillary sinus floor elevation was 94%. The types of implant, surface, graft material, bone height have no statistically signi-ficant differencies. Conclusions: It can be suggested that maxillary sinus floor elevation may have predictable result with various bone graft materials and implant surface.

상악동거상술시 자가골 복합이식이 골재생에 미치는 영향 (The effects of autogenous composite grafts on bone regeneration after sinus elevation)

  • 나의성;권영혁;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제34권2호
    • /
    • pp.377-392
    • /
    • 2004
  • The purpose of this present study was to investigate the effect of autogenous bone with histological evaluation of regenerated bone after sinus elevation. The study involved genaral healthy 6 patients participated in this study and were treated with 2-stage sinus elevation procedures using a combination of demineralized freezed-dried bone allograft (DFDBA) and coralline calcium carbonate with or without autogenous bone. At 6months after sinus elevation, bone specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation. The results of this study were as follows : 1. Autogenous bone grafts present trabecular patterns at 6 months in test groups, consist of woven bone and lamellar bone, but more compact than control groups. 2. Resorption of bone graft particles, osteoblast-like cells, newly formed osteoid tissue were observed at 6 months in test groups, but seems to be more frequently than control groups. 3. New osteoid tissue was formed from the surface of graft materials and gradually expanded around them. 4. The appearance of connective tissue around graft materials was densely formed, but more prominent in test groups than control groups. 5. Bone graft particles were resorbed incompletely and slight inflammatory infiltrate, newly formed capillaries, and adipocytes were observed. From the above results, autogenous bone is effective in bone regeneration after sinus elevation, could provide favorable conditions in implant placement.

Sinus floor elevation and simultaneous implant placement in fresh extraction sockets: a systematic review of clinical data

  • Ekhlasmandkermani, Mehdi;Amid, Reza;Kadkhodazadeh, Mahdi;Hajizadeh, Farhad;Abed, Pooria Fallah;Kheiri, Lida;Kheiri, Aida
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권6호
    • /
    • pp.411-426
    • /
    • 2021
  • Combining different procedures to reduce the number of surgical sessions and patient discomfort in implant placement and sinus floor elevation has been recommended, and evidence supports good outcomes. The aim of this study was to review the results of clinical studies on sinus floor elevation through extraction sockets and simultaneous immediate posterior implant placement. An electronic search was carried out in PubMed, Scopus, and Web of Science to find English articles published in or before August 2020. A manual search was also performed. Titles, abstracts, and the full-text of the retrieved articles were studied. Thirteen studies met our eligibility criteria: 6 retrospective case series, 3 case reports, 2 prospective cohort case-series, 1 prospective case series, and 1 randomized controlled trial. Overall, 306 implants were placed; 2 studies reported implant survival rates of 91.7% and 98.57%. The others either did not report the survival rate or reported 100% survival. Sinus floor elevation through a fresh extraction socket and simultaneous immediate implant placement appears to be a predictable modality with a high success rate. However, proper case selection and the expertise of the clinician play fundamental roles in the success of such complex procedures.

Assessment of dentists' subjective satisfaction with a newly developed device for maxillary sinus membrane elevation by the crestal approach

  • Kim, Young-Kyun;Cho, Yong-Seok;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.308-314
    • /
    • 2013
  • Purpose: The purposes of this study were to assess the dentists' subjective satisfaction with the crestal approach sinus (CAS) kit, a device for maxillary sinus membrane elevation by the crestal approach using a special drilling system and hydraulic pressure, and to summarize the subjective satisfaction of dental implants placed after a sinus lift procedure with the CAS kit. Methods: Thirty dental clinicians who had experience with dental implant placement after a sinus lift procedure with the CAS kit from June 2010 to May 2012 were included in this study. The questionnaire for the evaluation of the dentists' subjective satisfaction with the CAS kit was sent to the respondents and returned. The questionnaire was composed of two main parts. The first part was related to the sinus membrane perforation rate. The second part was related to the dentists' subjective satisfaction with the CAS kit. Results: A total of 28 dentists answered the questionnaire. Among 924 implant cases, sinus membrane perforation occurred in 38 cases (4.1%). Among the 28 dentists, 26 dentists (92.9%) were satisfied or very satisfied with the CAS kit. In particular, 24 dentists (85.7%) reported that safety, cutting performance, and user-friendliness of the CAS drill were advantages of the CAS kit. However, 7 dentists (25%) did not routinely use the hydraulic lifter for sinus membrane elevation. Conclusions: From the survey, it was shown that the respondents were generally satisfied with the CAS kit and that the cutting performance and safety of the drill component were considered strengths of the CAS kit.

Multicenter clinical study on the hydrodynamic piezoelectric internal sinus elevation (HPISE) technique

  • Lee, Hyung-Ju;Moon, Jee-Won;Lee, Ju-Hyoung;Park, In-Sook;Kim, Nam-Ho;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권2호
    • /
    • pp.85-89
    • /
    • 2012
  • Objectives: This study was to evaluate the effect of vertical bone gain and success rate and analyze the failure cases using the hydrodynamic piezoelectric internal sinus elevation (HPISE) technique. Materials and Methods: Patients who had been operated in the three centers including Daegu Catholic University Medical Center were selected for this study. The mucoperiosteal flap was elevated, and the sinus floor was then broken by specially designed piezoelectric insert, with hydraulic pressure applied to the sinus membrane for even elevation. Afterward, implants were placed. Panoramic radiogram or computed tomogram was taken before and after surgery and at the second operation and prosthesis placement. Later, changes in vertical height were measured and compared. The survival rate was based on the criteria of Buser et al. and Cochran et al. Results: In this study, 8 implants failed out of a total of 169 implants, resulting a success rate of 95.3%. These failure cases were due to insufficient initial stability or sinus membrane perforation. The mean of radiographic vertical height change at prosthesis placement was 5.7 mm (0.5-10.5 mm). Conclusion: In this study, HPISE technique was found to be a predictable treatment for atrophic maxilla and an alternative technique to the lateral approach.

Prognosis of Maxillary Sinus Augmentation in the Presence of Antral Pseudocyst: Case Reports

  • 마득현;김수관;오지수;유재식;김원기;양정은;임형섭
    • 대한치과의사협회지
    • /
    • 제54권10호
    • /
    • pp.771-779
    • /
    • 2016
  • Purpose: Antral pseudocyst is a common benign lesion that exists in the maxillary sinus. Because of this possible complication, controversy remains with respect to sinus floor elevation operations. The purpose of this study was to analyze the antral pseudocyst related to maxillary sinus augmentation. Patients and Methods: The radiographs of 268 patients who visited Chosun University Dental Hospital from 2008 to 2010 and underwent the maxillary bone grafting procedure were examined. Results: Of the 268 patients who underwent the maxillary bone grafting procedure, 5 patients (1.86%) were diagnosed with antral pseudocysts. In all cases, maxillary sinus floor elevation was performed without aspiration, biopsy or extraction of the antral pseudocyst. Conclusion: Antral pseudocysts are not considered a contraindication for maxillary sinus bone grafting procedure.

  • PDF

Benign paroxysmal positional vertigo as a complication of sinus floor elevation

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • 제40권2호
    • /
    • pp.86-89
    • /
    • 2010
  • Purpose: Osteotome sinus floor elevation (OSFE) is an often-used technique of great utility in certain implant patients with resorbed posterior maxilla. Recently benign paroxysmal positional vertigo (BPPV) has been reported as an early postoperative complication following OSFE. Although OSFE-induced BPPV commonly resolves itself within a month without treatment, this complication can be a cause of trouble between the implant surgeon and patient. This report presents a case of BPPV following OSFE. Methods: A 27-year-old man without any significant medical problems and missing his maxillary right first molar, was scheduled for OSFE and simultaneous implant placement. Results: The patient suffered dizziness accompanied by nausea immediately after implant placement using OSFE. Following referral to the ear nose throat clinic, "right posterior canal BPPV" was diagnosed. Despite anti vertigo medication and a single episode of the Epley maneuver, the condition did not improve completely. The Epley maneuver was then applied 7 and 8 days later and the symptoms of BPPV disappeared. One year later, the patient remained symptom-free. Conclusions: Before sinus elevation with an osteotome, implant surgeons should screen out patients with a history of vertigo, to diminish the possibility of BPPV. Operators should be aware of BPPV symptoms. As the symptoms may be very incapacitating, immediate referral to an otorhinolaryngologist is recommended.

콘빔형 전산화단층영상을 이용한 상악동 측벽의 형태학적 분석 (Morphological Analysis of the Sinus Lateral Wall Using Cone-Beam Computed Tomography)

  • 안서영;김용건
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.349-357
    • /
    • 2012
  • 이번 연구의 목적은 콘빔형 전산화단층촬영술(cone-beam computed tomography)을 이용하여 상악동 측벽의 두께를 측정하고, 이를 바탕으로 상악동 거상술을 위한 측벽창(lateral wall window)형성 시 가장 적절한 수직적 위치를 평가하는 것이다. 2010년 7월부터 2012년 6월까지 경북대학교 치과병원에 내원한 53명(남 : 36명, 여 : 17명, 평균나이 : 51.5세)의 상악동거상술 예정 환자의 콘빔형 전산화단층영상을 대상으로 하였다. 상악동 측벽의 두께는 상악 제2소구치, 제1대구치, 제2대구치 부위에서 상악동 하연을 포함하여 상악동 하연을 기준으로 수직적으로 1 mm 간격으로 6 mm 까지 측정하였고, 2회 반복 측정하여 평균을 구하였다. 상악동 측벽의 두께는 상악동 하연(Sinus Inferior Border, SIB)을 기준으로 상방 2 mm (SIB+2)까지는 2 mm 이상으로 관찰되었고, 상악동의 하연을 기준으로 3 mm 상방 (SIB+3)에서는 2 mm 미만으로 나타났으며, 상악동 하연을 기준으로 4 mm 상방에서는 두께가 거의 일정한 것으로 나타났다. 이번 연구 결과를 바탕으로 측방 접근법을 이용한 상악동 거상술에서 측벽창의 하방 위치는 상악동 측벽의 두께를 고려할 때 상악동의 하연을 기준으로 약 3 mm 상방에서 형성하는 것이 적절할 것으로 생각된다.

한국인에서의 상악동 골이식술과 관련된 상악동 동맥 분포에 대한 예비 연구 (ARTERIAL ARCADE OF THE MAXILLARY SINUS RELATED TO SINUS BONE GRAFT IN KOREAN POPULATION ; A PRELIMINARY STUDY USING COMPUTED TOPOGRAPHIES)

  • 김기영;김상균;서현수;송윤정;김미자;홍순민;박준우
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권4호
    • /
    • pp.475-479
    • /
    • 2008
  • Aim: The aim of this study was to investigate the arterial arcade of maxillary sinus by determining the distance between the alveolar crest and the inferior border of the vessels in Korean population. Materials and methods: 76 patients and 87 available sinuses were determined by CT scan (Implagraphy, Vatech, Seoul, Korea). The distance between alveolar crest and inferior border of the vessel was determined considering the tooth area of posterior maxilla. Results: The lowest distance was observed on first molar area and the average distance is 16.9 mm. Discussions: it is important in sinus lift surgery that the vessels not to be damaged and that the anastomosis is situated in the lateral wall of maxillary sinus, which has to be exposed to gain access to the maxillary sinus. The knowledge of arterial arcade of maxillary sinus is important to perform the sinus floor elevation procedure effectively.