• Title/Summary/Keyword: Single-shade composite resin

Search Result 7, Processing Time 0.029 seconds

Color Matching of Single-Shade Composite Resin by Various Pulp Capping Materials in Anterior Teeth

  • Sohyun Park;Jongsoo Kim;Jongbin Kim;Mi Ran Han;Jisun Shin;Joonhaeng Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.2
    • /
    • pp.176-184
    • /
    • 2024
  • This study aimed to compare color matching between single-shade composite resin-restored teeth with various pulp capping materials and the dentin surrounding the restoration through instrumental analysis and visual evaluation of the color difference. Fifty maxillary right central incisor acrylic resin teeth were prepared with standardized Class III cavities on the proximal surfaces. These teeth were divided into five groups: restored with single-shade composite resin only; Ultra-BlendTM plus followed by single-shade composite resin; TheraCal PTTM followed by single-shade composite resin; Endocem® MTA premixed followed by single-shade composite resin; and Well-root PTTM followed by single-shade composite resin. The color difference (ΔEab*) between the restored area and the center of the resin teeth was measured using a spectrophotometer. No significant color difference was observed in groups restored with only single-shade composite resin, Ultra-BlendTM plus, and TheraCal PTTM. The visual evaluation revealed that Ultra-BlendTM plus exhibited the best color matching score, whereas the Endocem® MTA premixed and Well-root PTTM groups showed significantly lower color matching scores than the single-shade composite resin-only group. When opting for single-shade composite resin usage for anterior tooth restorations with the aim of reducing chair time, pulp capping materials Ultra-BlendTM plus and TheraCal PTTM provide esthetically pleasing results.

Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth (유치에서의 단일 색조 복합레진의 색조 적응력 평가)

  • Yongsoon Kim;Howon Park;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.113-120
    • /
    • 2023
  • Restoring composite resins with the optimal shades for all primary teeth is a great challenge for pediatric dentists. A newly developed single-shade composite resin can exhibit a color similar to that of the surrounding tooth structure based on the structural color phenomenon. This study aims to evaluate the color adjustment potential (CAP) of a single-shade composite resin compared to conventional multi-shade composite resins in primary teeth. A single-shade composite resin and two conventional multi-shade composite resins were included in this study. Two types of specimens, a single specimen and a dual specimen, were evaluated. For single specimens, duplications of the primary second molar denture teeth were made using experimental composite resins. For dual specimens, cavities were prepared on the buccal surfaces of extracted primary second molars and restored with experimental composite resins. The L*, a*, and b* values were measured using a colorimeter for the extracted teeth and specimens. The mean ΔEab* values for single and dual specimens and CAP were calculated. Bonferroni post-hoc analysis was performed to confirm the statistical significance between the ΔEab* and CAP values of the experimental resins. Among the single specimens, the single-shade composite resin showed significantly higher ΔESingle compared to other composite resins (p < 0.0167). There was no significant difference between ΔEDual for all experimental resins. The single-shade composite resin showed highest CAP compared to other multi-shade composite resins. A single-shade composite resin exhibited the most prominent color adaptability compared to other conventional multi-shade composite resins for primary second molars. A single-shade composite resin can simplify shade matching and provide esthetic outcomes for the restoration of primary second molars.

Colorimetric comparison of single layered dental composite with double layered dental composite (색상 측정 기기를 이용한 복합레진 적층 수복과 단일 수복의 색상 비교 분석)

  • Song, Young-Sang;Kim, Ja-Hyun;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • Objectives: This study analyzed the difference in color caused by different thickness in enamel layer of composite resins when applied with single and layering placement technique, and evaluated if the results agreed with the shade guide from the manufacturers to verify reliability of the color matching process of the manufacturers. Materials and Methods: For single composite resin samples, 6 mm diameter and 4 mm thickness cylindrical samples were fabricated using Ceram-X mono (DENTSPLY DeTrey) and CIE $L^*a^*b^*$ values were measured with spectrophotometer. Same process was done for layering composite resin samples, making 3 dentinal shade samples, 4 mm thickness, for each shade using Ceram-X duo (DENTSPLY DeTrey) and enamel shade resins were layered in 2 mm thickness and CIE $L^*a^*b^*$ values were measured. These samples were ground to 0.2 mm thickness each time, and CIE $L^*a^*b^*$ values were measured to 1 mm thickness of enamel shade resin. Results: Color difference (${\Delta}E^*$) between single and layering composite resin was 1.37 minimum and 10.53 maximum when layering thicknesses were between 1 mm and 2 mm and 6 out of 10 same shade groups suggested by manufacturer showed remarkable color difference at any thickness (${\Delta}E^*$ > 3.3). Conclusion: When using Ceram-X mono and duo for composite resin restoration, following the manufacturer's instructions for choosing the shade is not appropriate, and more accurate information for Ceram-X duo is needed on the variation and expression of the shades depending on the thickness of the enamel.

Color discrepancy of single-shade composites at different distances from the interface measured using cell phone images

  • Marcia Luciana Carregosa Santana;Gabriella de Jesus Santos Livi;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.1
    • /
    • pp.7.1-7.11
    • /
    • 2024
  • Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS (광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Yang, Chol-Young;Yoo, Hyeon-Mee;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF