• Title/Summary/Keyword: Single-probe method

Search Result 141, Processing Time 0.025 seconds

Crystal growth and optical properties of near-stoichiometric $Zn:LiNbO_3$ fiber single crystal by ${\mu}-PD$ method (${\mu}-PD$ 법으로 성장시킨 near-stoichiometric 조성 $Zn:LiNbO_3$ fiber 단결정 성장 및 광손상 특성)

  • Lee, H.J.;Shur, J.W.;Shin, T.I.;Song, W.Y.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.6
    • /
    • pp.235-239
    • /
    • 2006
  • ZnO-doped near-stoichiometric $LiNbO_3$ single crystals of $0.8{\sim}1.0mm$ diameter and $30{\sim}35mm$ length were grown by the micro-pulling down (U-PD) method. The structure of the grown crystals was confirmed by powder x-ray diffraction (XRD) patterns. Electron probe micro analysis (EPMA) showed that Zn ions were homogeneously incorporated In grown crystals. The threshold in ZnO doping level was confirmed that an abrupt change in the features of $OH^-$ absorption band as doping level reaching about 2 mol%.

Thermo-piezoelectric $Si_3N_4$ cantilever array on a CMOS circuit for probe-based data storage using wafer-level transfer method (웨이퍼 본딩을 이용한 탐침형 정보 저장장치용 압전 켄틸레버 어레이)

  • Kim Young-Sik;Jang Seong-Soo;Lee Caroline Sun-Young;Jin Won-Hyeog;Cho Il-Joo;Nam Hyo-Jin;Bu Jong-Uk
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.96-99
    • /
    • 2006
  • In this research, a wafer-level transfer method of cantilever away on a conventional CMOS circuit has been developed for high density probe-based data storage. The transferred cantilevers were silicon nitride ($Si_3N_4$) cantilevers integrated with poly silicon heaters and piezoelectric sensors, called thermo-piezoelectric $Si_3N_4$ cantilevers. In this process, we did not use a SOI wafer but a conventional p-type wafer for the fabrication of the thermo-piezoelectric $Si_3N_4$ cantilever arrays. Furthermore, we have developed a very simple transfer process, requiring only one step of cantilever transfer process for the integration of the CMOS wafer and cantilevers. Using this process, we have fabricated a single thermo-piezoelectric $Si_3N_4$ cantilever, and recorded 65nm data bits on a PMMA film and confirmed a charge signal at 5nm of cantilever deflection. And we have successfully applied this method to transfer 34 by 34 thermo-piezoelectric $Si_3N_4$ cantilever arrays on a CMOS wafer. We obtained reading signals from one of the cantilevers.

  • PDF

Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP (몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가)

  • Kang, Sung-Il;Kim, Ji-Yeon;Kim, Suk Mi;Lee, Jin Ju;Sung, So-Ra;Kim, Yeon-Hee;Jung, Suk Chan;Her, Moon
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Up-conversion Property of Er2O3 and MgO Co-doped Stoichiometric LiNbO3 Single Crystal by Using the μ-PD Method (μ-PD법을 이용하여 성장시킨 Er2O3와 MgO를 첨가한 화학양론조성 LiNbO3 단결정의 Up-conversion 특성)

  • Shur, Joong-Won;Jeon, Won-Nam;Lee, Sung-Mun;Yang, Woo-Seok;Lee, Han-Young;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.835-839
    • /
    • 2002
  • Stoichiometric $LiNbO_3$(LN) single crystals of 1 mm diameter and 30∼40 mm length with co-doped the $Er_2O_3$ and MgO were grown by the Micro-Pulling Down(${\mu}$-PD) method. The grown crystals were investigated for the change of the up-conversion property by the $Er_2O_3$ and MgO addition and the optical damage by the MgO concentration. Also, the crystals were studied the defects using the optical microscope and it is identified the homogeneities of the distribution of the $Er_2O_3$ and MgO concentration by the Electron Probe Micro Analysis(EPMA).

TSSG-pulling of Sillenite $Bi_{12}TiO_{20}$ for EOS Application

  • Miyazawa, Shintaro
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.227-250
    • /
    • 1999
  • The reproducibility of successive growth of Bi12TiO20(BTO) single crystals using a top-seeded solution growth (TSSG) pulling method was evaluated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established experimentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasize that a starting solution, with a 10.0~10.1 mol% TiO2 concentration, results in large single crystals with a highly homogeneous lattice constant of within $\pm$1x10-4$\AA$, when the solidified fraction of the grown crystal is less than about 45%. A wavelength dispersion of refractive index was measured for the first time, an it was verified that the refractive index of BTO is larger than that of BSO(Bi12TiO20), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

TSSG-pulling of sillenite $Bi_{12}TiO_{20}$ for EOS application

  • Miyazawa, Shintaro
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.424-431
    • /
    • 1999
  • The reproducibility of successive growth of $Bi_{12}TiO_{20}$ (BTO) single crystlas using a top-seeded solution growth (TSSG) pulling method was evalutated by measuring the lattice constants and their standard deviations. A substantial phase diagram in the region close to the stoichiometric BTO was established expermentally for this purpose, and the existence of a retrograde solid solution close to a BTO was clarified. It was emphasized that a starting solution, with a 10.0~10.1 mol% $TiO_{2}$ concentration, results in large single crystals with a highly homogeneous lattice constant of within ${\pm}1{\times}10^{-4}\AA$, when the solidified fraction of the grown crystal is less than about 45 %. A wavelength dispersion of refractive index was measrued for the first time, and it was verified that the refractive index of BTO is larger than that of BSO($Bi_{12}TiO_{20}$), allowing the voltage sensitivity of EOS higher than the case with BSO as a probe head.

  • PDF

Fine YBaCuO Powder Prepared by Sol-gel Method

  • Soh, Deawha;Li, Fenghua;Wang, Jue;Fan, Zhanguo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.470-473
    • /
    • 2002
  • In order to get proper original suspension for the electrophoresis process of making YBaCuO films, YBaCuO superconductor powder was prepared with the Sol-gel method. The composition of the powder was analyzed by X-ray diffraction, which was identified as YBa$_2$Cu$_3$O$\sub$7-x/(Yl23) phase. The form of YBaCuO single particle was showed to be spherical by scanning electronic microscope and its size was among 0.2-1 $\mu\textrm{m}$. The critical transition temperature (T$\sub$c/) and the critical current density (J$\sub$c/) were measured with the four-probe, method. The T$\sub$c/ was about 91 K, and the J$\sub$c/ was 5-30 A/$\textrm{cm}^2$.

  • PDF

Experimental Study on Measuring the Intermittency in the Transitional Boundary Layer (천이경계층에서의 간헐도 측정에 관한 실험적 연구)

  • 임효재;안재용;백성구;정명균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • An experimental study was performed to investigate the turbulence intermittency measuring methods across the boundary layer in the transition region. A single type hot-wire probe was used to measure instantaneous streamwise velocities in laminar, transitional and turbulent boundary layer To estimate wall shear stresses on the flat plate, near wall mean velocities are applied to the principle of CPM. Distribution of intermittency factor is obtained by dual-slope method and compared to the results of four methods,$\'{u},\;\{U}$, TERA and M-TERA method. In these methods, M-TERA shows a good agreement in the near wall region. However, the result of M-TERA method shows that intermittency factor is underestimated in the outer part and outside of the boundary layer and the dimensional constant of M-TERA method should be changed appropriately depending on measuring point.

MLPA Applications in Genetic Testing (유전자진단에 있어서 Multiplex Ligation Dependent Probe Amplification (MLPA)의 이론과 실제)

  • Kim, Gu-Hwan;Lee, Beom-Hee;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.146-154
    • /
    • 2009
  • Multiplex ligation dependent probe amplification (MLPA) is a PCR-based method to detect gene dosage. Since its introduction, MLPA has been used to test a large number of genes for major deletions or duplications. Genetic testing, as a diagnostic tool for genetic disease, has been used primarily to identify point mutations, including base substitutions and small insertions/deletions, using PCR and sequence analysis. However, it is difficult to identify large deletions or duplications using routine PCR- gel based assays, especially in heterozygotes. The MLPA is a more feasible method for identification of gene dosage than another routine PCR-based methods, and better able to detect deleterious deletions or duplications. In addition to detection of gene dosage, MLPA can be applied to identify methylation patterns of target genes, aneuploidy during prenatal diagnoses, and large deletions or duplications that may be associated with various cancers. The MLPA method offers numerous advantages, as it requires only a small amount of template DNA, is applicable to a wide variety of applications, and is high-throughput. On the other hand, this method suffers from disadvantages including the possibility of false positive results affected by template DNA quality, difficulties identifying SNPs located in probe sequences, and analytical complications in quantitative aspects.

  • PDF

A Technique for Defect Detection of Condenser Tube in Support Plate Region using Guided Wave (유도초음파를 이용한 복수기 튜브지지판 영역에서의 결함검출기법)

  • Kim, Yong-Kwon;Park, Ik-Keun;Park, Sae-Jun;Ahn, Yeon-Shik;Gil, Doo-Song
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.36-41
    • /
    • 2012
  • General condensers consist of many tubes supported by tube sheets and support plates to prevent the deflection of the condenser tubes. When a fluid at high pressure and temperature runs over the tubes for the purpose of transferring heat from one medium to another, the tubes vibrate and their surface comes into contact with the support plates. This vibration causes damage to the tubes, such as cracks and wear. We propose an ultrasonic guided wave technique to detect the above problems in the support plate region. In the proposed method, the ultrasonic guided wave mode, L(0,1), is excited using an internal transducer probe from a single position at the end of the tube. In this paper, we present a preliminary experimental verification using a super stainless tube and show that the defects can be discriminated from the support signals in the support region.