• 제목/요약/키워드: Single-photon emission

검색결과 189건 처리시간 0.029초

Eco-Friendly Light Emitting Diodes Based on Graphene Quantum Dots and III-V Colloidal Quantum Dots

  • Lee, Chang-Lyoul
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.65-65
    • /
    • 2015
  • In this talk, I will introduce two topics. The first topic is the polymer light emitting diodes (PLEDs) using graphene oxide quantum dots as emissive center. More specifically, the energy transfer mechanism as well as the origin of white electroluminescence in the PLED were investigated. The second topic is the facile synthesis of eco-friendly III-V colloidal quantum dots and their application to light emitting diodes. Polymer (organic) light emitting diodes (PLEDs) using quantum dots (QDs) as emissive materials have received much attention as promising components for next-generation displays. Despite their outstanding properties, toxic and hazardous nature of QDs is a serious impediment to their use in future eco-friendly opto-electronic device applications. Owing to the desires to develop new types of nanomaterial without health and environmental effects but with strong opto-electrical properties similar to QDs, graphene quantum dots (GQDs) have attracted great interest as promising luminophores. However, the origin of electroluminescence (EL) from GQDs incorporated PLEDs is unclear. Herein, we synthesized graphene oxide quantum dots (GOQDs) using a modified hydrothermal deoxidization method and characterized the PLED performance using GOQDs blended poly(N-vinyl carbazole) (PVK) as emissive layer. Simple device structure was used to reveal the origin of EL by excluding the contribution of and contamination from other layers. The energy transfer and interaction between the PVK host and GOQDs guest were investigated using steady-state PL, time-correlated single photon counting (TCSPC) and density functional theory (DFT) calculations. Experiments revealed that white EL emission from the PLED originated from the hybridized GOQD-PVK complex emission with the contributions from the individual GOQDs and PVK emissions. (Sci Rep., 5, 11032, 2015). New III-V colloidal quantum dots (CQDs) were synthesized using the hot-injection method and the QD-light emitting diodes (QLEDs) using these CQDs as emissive layer were demonstrated for the first time. The band gaps of the III-V CQDs were varied by varying the metal fraction and by particle size control. The X-ray absorption fine structure (XAFS) results show that the crystal states of the III-V CQDs consist of multi-phase states; multi-peak photoluminescence (PL) resulted from these multi-phase states. Inverted structured QLED shows green EL emission and a maximum luminance of ~45 cd/m2. This result shows that III-V CQDs can be a good substitute for conventional cadmium-containing CQDs in various opto-electronic applications, e.g., eco-friendly displays. (Un-published results).

  • PDF

Alzheimer's Disease의 대사영상패턴 분석 (Metabolic impairment pattern analysis of the Alzheimer's disease)

  • 주라형;이창욱;정용안;최보영;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.91-95
    • /
    • 2004
  • 알츠하이머병에서는 전산화 단층촬영영상이나 자기공명영상을 이용하여 구조적, 비특이적 뇌 위축등의 병변을 진단할 수는 있으나 뇌 당대사 및 혈류 분포에 의한 이상 유무를 진단하기 위해서는 단일광자방출 단층촬영술 (single photon emission computed tomography, SPECT) 이나 양전자 방출 단층촬영술 (positron emission tomography, PET)을 이용한 국소 뇌혈류나 뇌 당대사 변화를 관찰한 진단이 필수적이다. 따라서 SEPCT나 PET영상 위에 직접 관심영역(region of interest, ROI)를 그려서 ROI를 관찰하여 해부학적 뇌위축과 국소 뇌혈류나 뇌 당대사 변화를 분석하였으나 ROI 방법은 주관적인 영향과 많은 분석 시간을 요하는 단점이 있다. 따라서 통계적 분석 방법을 이용한 맵핑방법으로 voxel based morphometry 방법을 수행하였고 MMSE 값을 분산분석변수로 하여 영상분석하여 $^{18}$F-labeled 2-deoxyglucose ($^{18}$F-FDG) positron emission tomography(PET)-CT 영상을 분석하였다. MMSE 값을 변수로 분석한 voxel based morphemetry 방법에서는 MMSE 값에 의한 대사저하의 변화는 무의미하였다. 알츠하이머병에서는 측두두정엽(temporoparietal cortex)의 cerebral blood flow, oxygen utilization, glucose metabolism은 줄어들고, 일차시각피질, 일차감각피질, 기저핵, 시상, 소뇌는 유지되며 voxel based morphometry 방법은 알츠하이머병을 분석하는데 유용한 분석방법이다.

  • PDF

뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구 (A study on image registration and fusion of MRI and SPECT/PET)

  • 주라형;최용;권수일;허수진
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 1998
  • 방사성 의약품 또는 방사성 동위원소를 이용하여 동적 상태의 변화를 측정하고 핵자기 공명 영상에서 해부학적 기준 정보를 얻어 영상을 융합, 등록하고 같은 대상에서 비슷한 검사를 계속해서 비교하게 되며 해부학적 기준 정보나 다른 검사 기기 종류에서 반복되는 검사의 비교를 위해 영상 합성 연구가 유효하며 기능적 특성 때문에 단일 광자 방출 전산화 단층 촬영과 양전자 방출 단층 촬영은 해부학적 기준 정보가 필요하게 되고 같은 대상에서 이러한 해부학적 기준 정보를 얻고 기능적인 이상과 상관관계를 찾아내고 반복되는 진단에 대한 비교를 위해서 영상등록과 융합을 시행하였다. 해부학적 구조가 같은 특성을 갖는 여러 영상 시스템들을 이용하여 해부학적기준과 동적 정보를 함께 얻고 등록하기 위해 짝을 이루는 점올 이용하여 2 가지 영상 데이터에서 4 점 쌍 이상을 선택하여 등록하였다. 기준 영상과 짝을 이루는 점과 대응한 영상은 다른 색을 선택하여 영상을 구분하였으며 핵자기 공명영상을 기준영상으로 하고 단일 광자 방출 컴퓨터 단층 촬영 영상, 양전자 방출 전산화 단층 촬영 영상을 기준영상에 1:1 대응하여 영상을 등록하기 위해서 변환한다. 핵자기 공명 영상이 기준 영상으로 사용되지만 인터폴레이션 에러는 주어진 영상의 공간 주파수에 따라 달라지므로 낮은 해상도를 갖는 양전자 방출 전산화 단층 촬영 영상과 단일 광자 방출 컴퓨터 단층 촬영 영상의 인터폴레이션 에러는 적다. 따라서 방사성 동위원소를 이용하여 질병의 진단 및 질환의 병태 생리 생화학적 연구를 통한 신체의 동역학적 상태의 변화를 측정할 수 있는 이런 정량적이고 기능적인 정보를 해부학적 기준 정보를 주는 핵자기 공명 영상이나 컴퓨터 단층 촬영에서 반복 시행하여 검사와 진단에 용이하게 이용하고, 비교를 위해서 영상을 등록하고 융합하여 진단에 보다 좋은 결과를 얻을 수 있도록 하였다.

  • PDF

핀홀콜리메이터를 사용한 핵의학영상기기의 순환적 영상 재구성을 위한 비동일 시스템 모델 개발 (Development of Unmatched System Model for Iterative Image Reconstruction for Pinhole Collimator of Imaging Systems in Nuclear Medicine)

  • 배재건;배승빈;이기성;김용권;정진훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.353-360
    • /
    • 2012
  • 핵의학 영상 기기 중 SPECT시스템은 촬영목적에 따라 다양한 콜리메이터를 사용하며 영상 재구성을 위해서는 각 콜리메이터의 기하학적 특성을 반영하는 것이 필요하다. 본 연구에서는 이 중 핀홀 콜리메이터를 사용한 핵의학 영상기기의 영상 재구성에 관한 연구를 수행하였으며 특히 핀홀 콜리메이터 영상 재구성시 발생하는 샘플링 문제를 제거하는 방법에 대한 연구를 수행하였다. 순환적 영상 재구성 방법의 투사(projection)와 역투사(back-projection)시 각기 다른 방식으로 구축된 시스템 모델을 반영한 비동일 시스템 모델 방식을 개발하여 최대우도 기댓값최대화(maximum likelihood expectation maximization, ML-EM) 알고리듬에 적용하였다. 설계한 재구성 알고리듬을 성능을 검증하기 위해 geant4 application for tomographic emission(GATE) 시뮬레이션 툴을 이용하여 핀홀 콜리메이터의 디지털 팬텀 시뮬레이션을 수행하고 이를 이용하여 기존방식과 제안한 방식의 재구성 알고리듬에 대한 비교평가 연구를 수행하였다. 그 결과 본 연구에서 제안한 비동일 시스템 모델 사용 영상 재구성 방법은 동일 시스템 모델을 사용한 순환적 재구성 알고리듬에 비해 효과적으로 샘플링 문제를 제거할 수 있는 것을 확인 할 수 있었다. 본 연구에서 제안한 영상 재구성 방법은 다양한 콜리메이터에 확대적용 되어 사용 될 수 있을 것으로 기대된다.

합성용질확산법에 의한 GaP결정의 성장과 전기루미네센스 특성 (On the Crystal Growth of Gap by Synthesis Solute Diffusion Method and Electroluminescence Properties.)

  • 김선태;문동찬
    • 한국재료학회지
    • /
    • 제3권2호
    • /
    • pp.121-130
    • /
    • 1993
  • 합성용질확산법으로 GaP 단결정을 성장시키고, 몇가지 성질을 조사하였다. 결정성장용 석영관을 전기로내에서 1.75mm/day의 속도로 하강시킴으로써 양질의 GaP 단결정을 성장하였다. 에치피트 밀도는 결정의 성장축 방향으로 3.8 ${\times}{10^4}$c$m^{-2}$부터 2.3 ${\times}{10^5}$c$m^2$이었다. 에너지갭의 온도의존성은 실험적으로 $E_g$(T)=[2.3383-(6.082${\times}{10^{-4}}$)$T^2$(373.096+T)eV로 구하여졌다. 저온에서의 광루미네센스 스펙트럼은 구속된 여기자의 복사재결합과 재결합 과정에 포논의 참여로 인하여 에너지갭 부근의 복잡한 선 스펙트럼이 나타났다. n형의 GaP내에서 Zn의 확산깊이는 확산시간의 제곱근에 비례하였으며, 확산계수의 온도의존성은 D(T)=3.2${\times}{10^3}$ exp(-3.486/KbTc$m^2$/sec이었다. p-nGaP 동종접합다이오드의 전기루미제센스 스펙트럼은 깊은 준위의 도너인 Zn-O 복합중심(complex center)과 Zn가 형성한 역셉터 준위사이의 도너-억셉터 쌍 재결합 천이에 의한 630nm의 발광과 에너지갭 부근의 케리어 재결합 처이에 의한 550nm의 발광으로 구성되었으며, 100mA보다 낮은 전류 영역에서 광자의 방출은 bane-filling 과정으로 이루어 진다.

  • PDF

Optical Characterizations of TlBr Single Crystals for Radiation Detection Applications

  • Oh, Joon-Ho;Kim, Dong Jin;Kim, Han Soo;Lee, Seung Hee;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.167-171
    • /
    • 2016
  • Background: TlBr is of considerable technological importance for radiation detection applications where detecting high-energy photons such as X-rays and ${\gamma}$-rays are of prime importance. However, there were few reports on investigating optical properties of TlBr itself for deeper understandings of this material and for making better radiation detection devices. Thus, in this paper, we report on the optical characterizations of TlBr single crystals. Spectroscopic ellipsometry (SE) and photoluminescence (PL) measurements at RT were performed for this work. Materials and Methods: A 2-inch TlBr single crystalline ingot was grown by using the vertical Bridgman furnace. SE measurements were performed at RT within the photon energy range from 1.1 to 6.5 eV. PL measurements were performed at RT by using a home-made PL system equipped with a 266 nm-laser and a spectrometer. Results and Discussion: Dielectric responses from SE analysis were shown to be slightly different among the different samples possibly due to the different structural/optical properties. Also from the PL measurements, it was observed that the peak intensities of the middle samples were significantly higher than those of the other two samples. With the given values for permittivity of free space (${\varepsilon}_0=8.854{\times}10^{-12}F{\cdot}m^{-1}$), thickness (d = 1 mm), and area ($A=10{\times}10mm^2$) of the TlBr sample, capacitances of TlBr were 6.9 pF (at $h{\nu}=3eV$) and 4.4 pF (at $h{\nu}=6eV$), respectively. Conclusion: SE and PL measurement and analysis were performed to characterize TlBr samples from the optical perspective. It was observed that dielectric responses of different TlBr samples were slightly different due to the different material properties. PL measurements showed that the middle sample exhibited much stronger PL emission peaks due to the better material quality. From the SE analysis, optical, dielectric constants were extracted, and calculated capacitances were in the few pF range.

단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가 (Comparative Evaluation of Resolution according to Frequency Change for SPECT)

  • 김성철;박수연;조영권;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.322-331
    • /
    • 2009
  • SPECT 장치에서 반치폭은 분해능을 평가할 수 있는 척도가 되므로, 본 연구에서는 검출기가 각각 2개와 3개가 있는 장치를 이용하여 우리나라에서 가장 많이 사용되는 7개의 필터 - Band limited, Sheep-logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth - 에 대해 세 개의 점선원으로 filter별로 MTF curve를 얻어 각각의 축방향에 따른 cut off level 과 profile 곡선을 이용하여 반치폭(FWHM)의 크기의 변화를 관찰하였다. 실험 결과 모든 filter에서 cut off level 0.4였을 때 가장 큰 반치폭의 길이가 측정되어 분해능이 가장 떨어졌고, cut off level 0.7에서 가장 높은 분해능을 보였다. MS2에서 가장 짧은 반치폭은 Butterworth filter사용시 $11.07\pm0.07mm$이었으며, MS3에서는 Hanning filter사용시 $8.44\pm0.19mm$로 나타났다.

VRML을 이용하는 3 차원 융합 영상의 가시화와 위치 측정 구현 : 간질 환자의 적용 예

  • 이상호;유선국;정해조;강원석;성민모;이재훈;김새롬;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.50-50
    • /
    • 2003
  • World Wide Web (WWW)에서 Virtual Reality Modeling Language (VRML)를 이용하는 3 차원 (3D) 디스플레이는 사용자에게 직관적인 정보를 더 효과적으로 제공해 준다. 웹을 기반으로 하는 해부학적 영상과 융합되는 기능적 영상의 3D 가시화는 아직까지 체계적인 방식으로 연구가 활발히 진행되지 않았다. 이 연구의 목적은 2D 영상들과 함께 웹에서 VRML을 이용하여 구현되는 3D 해부학적 표면 영상들과 기능적 표면 영상들을 동시적으로 관찰할 수 있게 하고 VRML을 통해 만들어진 거리 측정 도구를 가지고 관심영역의 공간적인 위치 정보를 제공하는 것이다. 본 연구에서는 한 명의 간질 환자로부터 Magnetic Resonance (MR) 축면 영상과 발작기 및 발작간기 Single Photon Emission Computed Tomo graphy (SPECT) 축면 영상들을 각각 획득하였다. 발작 진원지의 확인을 향상시키기 위해서 subtraction ictal SPECT co registered to MRI (SISCOM) 을 수행하였다. SISCOM 결과로 나타난 각 2D 영상들은 모든 voxel 들의 평균 값 위로 1 표준편차와 2 표준편차에 해당하는 문턱 이상의 영상 값을 갖도록 하였다. SISCOM으로 나타나는 간질 발작 진원지들과 MRI 영상에서 회색질, 백색질 및 뇌척수액의 경계들을 각각 분할하고 marching cube 알고리즘에 의해 VRML 표면 영상들로 나타내었다. 축면 영상에서 실제 거리를 나타내는 x, y 축의 길이를 측정하고 z 축선의 길이를 계산하였다. VRML을 이용한 거리 측정 도구를 만들어 이전의 VRML 표면 영상들과 융합하였다. MRI 영상을 이용하여 3D 표면 영상들의 단면을 나타내고 3D 표면 영상들의 투명도를 설정하기 위해 Java Script 루틴을 사용자 인터페이스 도구로서 삽입하였다. 웹 페이지에서 구현되는 3D 표면 영상들의 투명도와 관찰 위치를 조절함에 따라 모델들 사이의 공간적인 정보를 직관적으로 알 수 있었다. 간질 발작 진원지에 대응하는 해부학적 구조를 3D 표면 영상들을 가로지르는 MRI 평면 영상들을 통해서 확인하였다. 결론적으로 본 연구에서 제시하는 웹에 근거한 3D 융합 영상의 가시화와 위치 측정은 진단 및 치료 방사선학과 외과학 등의 분야에서 온라인 방식의 연구와 교육에 있어 많은 도움을 줄 것이다.

  • PDF

SPECT Image Analysis Using Computational ROC Curve Based on Threshold Setup

  • Kim, Moo-Sub;Shin, Han-Back;Kim, Sunmi;Shim, Jae Goo;Yoon, Do-Kun;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.77-82
    • /
    • 2017
  • We proposed the objective ROC analysis method based on the setting of threshold value for evaluation of single photon emission computed tomography (SPECT) image. This proposed ROC analysis method uses the quantification computational threshold value to each signal on the SPECT image. The SPECT images for this study were acquired by using Monte Carlo n-particle extended simulation code (MCNPX, Ver. 2.6.0, Los Alamos National Laboratory, USA). The basic SPECT detectors and specific water phantom were realized in the simulation, and we could get the simulation results by the simulation operation. We tried to analyze the reconstructed images using threshold value application based objective ROC method. We can get the accuracy information of reconstructed region in the image. This proposed ROC technique can be helpful when we have to evaluate the weak signal for the NM image. In this study, the proposed threshold value based computational ROC analysis method can provide better objectivity than the conventional ROC analysis method.

Neurological Improvement after Cranioplasty in Patients with Surgical Bony Defects : The Usefulness of Acetazolamide Activated $^{99m}Tc-HMPAO$ SPECT

  • Seo, Won-Duck;Kim, Young-Don;Hong, Dae-Young;Kim, Dae-Hyun;Choi, Gi-Hwan;Yeo, Hyung-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권6호
    • /
    • pp.434-440
    • /
    • 2006
  • Objective : The purpose of this study is to examine the influence of cranioplasty on dynamics of cerebral blood flow[CBF] and cerebrovascular reserve capacity[CVRC], and to investigate the usefulness of single photon emission computed tomography [SPECT] as a prognostic factor for neurological improvement after cranioplasty. Methods : Between March 2003 and December 2005, a prospective study was performed on 24 patients who had undergone total 25 cranioplasty operations. Cerebral blood flow velocities in the middle cerebral artery[MCA] and internal carotid artery[ICA] were obtained by transcranial Doppler ultrasonography[TCD]. The CVRC was assessed by SPECT in the natural state and after stimulation with 1g of acetazolamide. Neurological improvement after cranioplasty was compared between patients who showed hyperactivity to acetazolamide-activated SPECT [Group 1, n=7] and hypoactivity to acetazolamide-activated SPECT [Group 2, n=17]. These measurements were obtained two weeks prior to and two weeks after cranioplasty. Results : The blood flow velocities at the opposite site to the cranioplasty as well as at the cranioplasty site were significantly increased [P<0.05]. Compared with Group 2, there was significant increase in CBF and neurological improvement after cranioplasty in Group 1. Conclusion : Among patients with surgical bony defects, the patients who had normal reactivity of the CVRC showed a significant increase in CBF and neurological improvement after cranioplasty. The authors suggest that CVRC measurement prior to surgery may be an important prognostic factor for neurological improvement after cranioplasty.