• Title/Summary/Keyword: Single-photon emission

Search Result 189, Processing Time 0.03 seconds

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

Radio-Iodinated arbutin for tumor imaging

  • Huynh, Phuong Tu;Ha, Yeong Su;Lee, Woonghee;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.72-79
    • /
    • 2017
  • Arbutin is a hydroquinone derivative with a glucose moiety. As a tyrosinase inhibitor, it is widely used as a skin-whitening cosmetic agent for the treatment of cutaneous hyperpigmentary disorders, such as melasma and freckles. In the medical field, many studies have addressed the use of arbutin in various tumors, but the mechanism for tumor uptake of arbutin is still unclear. In this paper, we radiolabeled arbutin using radioiodine and studied its pharmacokinetics and tumor uptake via biodistribution experiments and single-photon emission computed tomography (SPECT) imaging. Radiolabeled $^{131}I-arbutin$ was stable for up to 24 h in PBS and serum. Biodistribution studies and SPECT imaging indicated high uptake of the compound in the bladder and kidneys shortly after injection. Twenty-four hours post-injection, significant deiodination was observed. Apart from high thyroid uptake, selective tumor uptake was clearly observed. The tumor-to-muscle and tumor-to-blood ratios were 26 and 9, respectively.

A Novel In Situ Gel Formulation of Ranitidine for Oral Sustained Delivery

  • Xu, Haoping;Shi, Min;Liu, Ying;Jiang, Jinling;Ma, Tao
    • Biomolecules & Therapeutics
    • /
    • v.22 no.2
    • /
    • pp.161-165
    • /
    • 2014
  • The main purpose of this study was to develop a novel, in situ gel system for sustained delivery of ranitidine hydrochloride. Ranitidine in situ gels at 0.2%, 0.5%, and 1.0% gellan gum concentration (w/v) were prepared, respectively, and characterized in terms of preparation, viscosity and in vitro release. The viscosity of the gellan gum formulations in solution increased with increasing concentrations of gellan gum. In vitro study showed that the release of ranitidine from these gels was characterized by an initial phase of high release (burst effect) and translated to the second phase of moderate release. Single photon emission computing tomography technique was used to evaluate the stomach residence time of gel containing $^{99m}Tc$ tracer. The animal experiment suggested in situ gel had feasibility of forming gels in stomach and sustained the ranitidine release from the gels over the period of at least 8 h. In conclusion, the in situ gel system is a promising approach for the oral delivery of ranitidine for the therapeutic effects improvement.

Occlusion of the Middle Cerebral Artery Branch Mimicking Aneurysm

  • Lee, Jung-Hwan;Ko, Jun-Kyeung;Lee, Sang-Weon;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.413-415
    • /
    • 2007
  • A 26-year-old man was admitted to our department due to intermittent left hemiparesis for 3 months. Magnetic resonance Image showed subacute infarction in the right precentral gyrus. Digital subtraction angiography and magnetic resonance angiography revealed an aneurysmal protrusion at the right middle cerebral artery (MCA) bifurcation. It was difficult to differentiate the aneurysm from the occlusion of the middle trunk of the MCA trifurcation. Brain single photon emission computerized tomography showed a decrease in perfusion in the right posterior frontal lobe without vascular reserve. Therefore, we planned a superficial temporal artery MCA anastomosis with an exploration of the right MCA bifurcation. Intraoperatively, the aneurysmal opacification on preoperative angiography proved to be the proximal stump of the occluded middle trunk of the MCA trifurcation. An aneurysmal protrusion at the MCA bifurcation does not always indicate an aneurysm. In diagnosing protruding vascular lesions at the MCA bifurcation, the possibility of a vascular stump should be considered according to their angioanatomical appearance and the history of the patient.

Comparison of planar scintigraphy and bone SPECT with clinical findings and other imaging modalities in temporomandibular disorder patients (측두하악관절장애 환자에서의 평면 골 스캔 및 Bone SPECT 소견과 임상적 및 영상학적 소견과의 비교)

  • Jeong Hee-Jeong;Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.91-97
    • /
    • 2004
  • Purpose : This study was performed to evaluate the diagnostic value of both planar and SPECT imagings by comparing the results with the clinical and other imaging modalities findings. Materials and Methods: A total of 578 joints with TMJ complaints were examined using planar scintigraphy and SPECT. The planar scintigraphy and SPECT findings were analyzed and compared to the clinical findings of pain, clicking, crepitus and limitation of mouth opening. Moreover we compared the accuracy of the planar scintigraphy and SPECT methods with the one of the panoramic, transcranial, tomographic and MR imaging methods. Results: The planar scintigraphy and SPECT methods showed a high sensitivity of 0.76-0.84 and low specificity of 0.25-0.45 toward the clinical findings: pain, clicking, crepitus and mouth opening restriction. Simple radionuclide uptake ratio was high in each group of patients with pain, crepitus, limitation of mouth opening (p < 0.05) complaints, in each group with positive bone changes on panoramic, transcranial or tomographic images, and in disc displaced group. Conclusion: Although both planar and SPECT imagings have limited specificity, these techniques are sensitive for detection of internal derangement of the TMJ.

  • PDF

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

A case of tacrolimus-induced encephalopathy after kidney transplantation

  • Kim, Myoung-Uk;Kim, Sae-Yoon;Son, Su-Min;Park, Yong-Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.1
    • /
    • pp.40-44
    • /
    • 2011
  • We present a case of tacrolimus-induced encephalopathy after successful kidney transplantation. An 11-year-old girl presented with sudden onset of neurologic symptoms, hypertension, and psychiatric symptoms, with normal kidney function, after kidney transplantation. The symptoms improved after cessation of tacrolimus. Magnetic resonance imaging (MRI) showed acute infarction of the middle cerebral artery (MCA) territory in the right frontal lobe. Three days later, she had normal mental function and maintained normal blood pressure with left hemiparesis. Follow-up MRI was performed on D19, showing new infarct lesions at both cerebral hemispheres. Ten days later, MRI showed further improvement, but brain single photon emission computed tomography (SPECT) showed mild reduction of uptake in both the anterior cingulate gyrus and the left thalamus. One month after onset of symptoms, angiography showed complete resolution of stenosis. However, presenting as a mild fine motor disability of both hands and mild dysarthria, what had been atrophy at both centrum semiovale at 4 months now showed progression to encephalomalacia. There are two points of interest in this case. First, encephalopathy occurred after administration of tacrolimus and improved after discontinuation of the drug. Second, the development of right-side hemiplegia could not be explained by conventional MRI; but through diffusion tensor imaging (DTI) and diffusion tensor tractography (DTT) of white matter tract, visualization was possible.

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.

A Case of Intestinal Hemangioma Complicated with Thrombocytopenia (Kasabach-Merritt syndrome) in Premature Infant (미숙아에서 혈소판 감소증에 의해 발견된 장 혈관종(Kasabach-Meritt 증후군) 1례)

  • Lee, Young-Jin;Bae, Sul-Hee;Song, Eun-Song;Choi, Soo-Jin-Na;Kim, Yoon-Ha;Choi, Young-Youn
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.116-122
    • /
    • 2010
  • Kasabach-Merritt syndrome is a rare thrombocytopenic consumptive coagulopathy associated with a giant hemangioma. We experienced a case of unexplained ascites with thrombocytopenia in a 32 week premature infant. An exploratory laparotomy was performed to determine the cause of the refractory ascites and thrombocytopenia. An intestinal hemangioma was found, but, surgical removal was not performed due to the extensive involvement. Hemangioma was confirmed by SPECT (single-photon emission computed tomography) and the thrombocytopenia was treated with steroid therapy. It is recommended that hemangioma of the visceral organs should be suspected when unexplained thrombocytopenia and disseminated intravascular coagulopathy persist.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.