• 제목/요약/키워드: Single-Phase

검색결과 5,326건 처리시간 0.03초

공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템 (Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side)

  • 유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

다중적분기 사용 +1, 0, -1 계수의 선형위상 FIR 필터의 설계 (FIR Linear Phase Filter Design Using Coefficients +1,0.-1 and Multiple Integrator)

  • Kim, Hyung-Myung
    • 대한전자공학회논문지
    • /
    • 제26권12호
    • /
    • pp.2046-2054
    • /
    • 1989
  • Improved algorithms are presented to design linear phase digital FIR filters with coefficients of +1,0,-1 only followed by a multiple integrator. It has been shown that the existing linear phase filter design concept for the single integrator(or, accumulator)case can be extended to the case of the multiple integrator. Linear phase conditions for the multiple integrators are summarized. Filter design methods with double or triple integrator are exploited in datail and its computer simulation results are presented to deduce the advantages of multiple integrator to the single integrator.

  • PDF

3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석 (Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL)

  • 박형민;최효상;조용선;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

보조계면활성제가 비이온 계면활성제의 Water in Oil 마이크로에멀젼을 이용한 실리카 나노입자 제조에 미치는 영향 (Effect of Cosurfactant on Preparation of Silica Nanoparticles using Water in Oil Microemulsion of Nonionic Surfactant)

  • 김태훈;임종주
    • Korean Chemical Engineering Research
    • /
    • 제46권2호
    • /
    • pp.356-368
    • /
    • 2008
  • 본 연구에서는 계면활성제, 오일, 암모니아 수용액으로 이루어진 시스템에 보조계면활성제 첨가가 단일상의 마이크로에멀젼을 이용한 실리카 나노입자 제조에 미치는 영향에 관하여 살펴보았다. 동일한 연속상의 오일을 사용한 경우, 단일상의 W/O 마이크로에멀젼 영역은 계면활성제와 연속상 오일의 상호작용에 의하여 결정되었다. 예를 들어 연속상 오일로 cyclohexane을 사용한 경우에는 실험에 사용한 NP(nonylphenol ethoxylate) 계면활성제 중에서 NP-5가 가장 넓은 W/O 마이크로에멀젼 영역을 나타냈으며, NP-4가 가장 좁은 W/O 마이크로에멀젼 영역을 나타내었다. NP 계면활성제 시스템에 n-propanol을 보조계면활성제로 첨가한 경우, 단일상의 영역은 연속상 오일의 종류에 따라 증가 또는 감소하였다. 예를 들어, cyclohexane과 isooctane 시스템에서는 n-propanol 첨가에 따라 단일상의 마이크로에멀젼 영역은 감소하나 n-heptane 시스템의 경우에는 증가하였다. 실리카 나노입자 실험을 수행한 결과에 의하면 NP 계면활성제 시스템의 경우 보조계면활성제를 첨가함에 따라 한 상의 영역에서의 제조와 관계없이 많은 수의 불균일한 입자가 생성되었다. LA-5 계면활성제와 n-heptane 시스템에서의 n-propanol 첨가는 입자의 크기는 감소하며, 개수는 증가하는 경향을 나타내었다. 이는 n-propanol 첨가량이 증가함에 따라 계면활성제의 소수 결합이 증가하여 마이크로에멀젼 사이의 상호 물질 교환이 잘 일어나지 않기 때문으로 생각된다.

KAlSiO4의 단결정 합성 및 동질 다상 (Synthesis of Single Crystal and Polymorphism of KAlSiO4)

  • 박병규;정수진
    • 한국세라믹학회지
    • /
    • 제25권1호
    • /
    • pp.73-77
    • /
    • 1988
  • Single crystals of kalsilite were synthesized by hydrothermal method at 420$^{\circ}C$-480$^{\circ}C$ and 100 atm-1500 atm. The crystal habits are similar to those of KLiSiO4 single crystals. The crystal structure was investigated by means of X-ray single crystal diffraction. The space group of kalsilite is P63. Phase transitiions were determined by use of DTA and high temperature X-ray Guinier camera. Phase transitions of kalsilite are summerized and discussed.

  • PDF

단상 유도형 동기 전동기(LSPM)의 특성해석에 관한 연구 (A Study on the Characteristics in Single-Phase Line-Start Permanent Magnet Moter)

  • 정대성;김승주;이진헌;최재학;이주
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.125-131
    • /
    • 2007
  • 가전분야에서의 전동기 효율향상을 통한 에너지 소비절감 효과는 상당히 크지만 이를 위한 전동기의 설계/해석 기술 확보가 아직은 미흡한 상태이다. 이에 따라 유도형 동기전동기가 제안되었지만, 유도형 동기 전동기는 유도전동기와 통기전동기의 특성을 동시에 가지고 있어, 해석 및 설계가 쉽지 않다. 따라서 본 논문에서는 기존의 냉장고 압축기용 전동기인 단상유도전동기를 대처할 수 있는 단상 유도형 동기전동기를 이용해 파라미터에 따라 특성이 어떻게 바뀌는가에 대해 서술하였다. 그에 따라 단상유도전동기의 정상상태 특성을 해석하고 제안모델의 성능을 기존모델과 비교하고 실험하여 해석결과의 신뢰성을 검증한다. 또한 본 논문에서는 제안모델의 기존 고정자 형상이나 권선 스팩을 유지하고 회전자의 형상이나 구조만을 변경시켜 성능향상을 도모하였다. 해석방법으로는 전자장 수치 해석적인 방법으로 널리 이용되고 있는 유한요소법(Finite Element Method : FEM)을 이용하였다.

분극된 <001> 방위 Pb(Mg1/3Nb2/3)O3-PbTiO3 단결정의 유전 특성 및 상전이 (Dielectric Properties and Phase Transformation of Poled <001>-Oriented Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystals)

  • 이은구;이재갑
    • 한국재료학회지
    • /
    • 제22권7호
    • /
    • pp.342-345
    • /
    • 2012
  • The dielectric properties and phase transformation of poled <001>-oriented $Pb(Mg_{1/3}Nb_{2/3})O_3-x%PbTiO_3$(PMN-x%PT) single crystals with compositions of x = 20, 30, and 35 mole% are investigated for orientations both parallel and perpendicular to the [001] poling direction. An electric-field-induced monoclinic phase was observed for the initial poled PMN-30PT and PMN-35PT samples by means of high-resolution synchrotron x-ray diffraction. The monoclinic phase appears from $-25^{\circ}C$ to $100^{\circ}C$ and from $-25^{\circ}C$ to $80^{\circ}C$ for the PMN-30PT and PMN-35PT samples, respectively. The dielectric constant (${\varepsilon}$)-temperature (T) characteristics above the Curie temperature were found to be described by the equation$(1/{\varepsilon}-1/{\varepsilon}_m)^{1/n}=(T-T_m)/C$, where ${\varepsilon}_m$ is the maximum dielectric constant and $T_m$ is the temperature giving ${\varepsilon}_m$, and n and C are constants that change with the composition. The value of n was found to be 1.82 and 1.38 for 20PT and 35PT, respectively. The results of mesh scans and the temperature-dependence of the dielectric constant demonstrate that the initial monoclinic phase changes to a single domain tetragonal phase and a to paraelectric cubic phase. In the ferroelectric tetragonal phase with a single domain state, the dielectric constant measured perpendicular to the poling direction was dramatically higher than that measured in the parallel direction. A large dielectric constant implies easier polarization rotation away from the polar axis. This enhancement is believed to be related to dielectric softening close to the morphotropic phase boundary.

Application of single phase D-Q rotating frame theory in a traction co-phase power supply system

  • Park, In Kwon;Elimban, Sumek;Zhang, Yi;Kuffel, Rick
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.216-218
    • /
    • 2017
  • The imbalance at the 3-phase side at the railway power supply substation has been a well-known issue. Due to the difference in status of loads at each phase at any given moment, it is difficult to maintain the balance in the 2-phase side of the transformer. Consequently, the 3-phase side also presents a certain level of imbalance as well. A co-phase power supply was proposed as a solution. The real application of such system is gradually expanding, proving the effectiveness of the system. In this paper, the application of the single phase D-Q rotating frame theory was applied to the control of the co-phase power supply system. In addition, the power stack of the system was composed of MMC valves, which offers superior operational characteristics. The effectiveness of the system was verified with a real-time simulation, and the results are presented.

  • PDF

Digital Control Strategy for Single-phase Voltage-Doubler Boost Rectifiers

  • Cho, Young-Hoon;Mok, Hyung-Soo;Ji, Jun-Keun;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.623-631
    • /
    • 2012
  • In this paper, a digital controller design procedure is presented for single-phase voltage-doubler boost rectifiers (VDBR). The model derivation of the single-phase VDBR is performed in the s-domain. After that the simplified equivalent z-domain models are derived. These z-domain models are utilized to design the input current and the output dc-link voltage controllers. For the controller design in the z-domain, the traditional K-factor method is modified by considering the nature of the digital controller. The frequency pre-warping and anti-windup techniques are adapted for the controller design. By using the proposed method, the phase margin and the control bandwidth are accurately achieved as required by controller designers in a practical frequency range. The proposed method is applied to a 2.5 kVA single-phase VDBR for Uninterruptible Power Supply (UPS) applications. From the simulation and the experimental results, the effectiveness of the proposed design method has been verified.

1선 지락사고에 대한 초전도한류기의 불평형 특성 (Unbalanced Characteristics of the Superconducting Fault Current Limiters with a Single Line-to-ground Fault)

  • 최효상;이나영;이상일
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.851-855
    • /
    • 2005
  • We investigated the unbalanced characteristics of the superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased about 6 times of transport currents after the fault onset but was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unbalanced rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unbalanced rates of currents were noticeably improved within one cycle after the fault onset. We calculated the zero phase currents for a single line-to-ground fault using the balanced component analysis. The positive sequence resistance was reduced remarkably right after the fault onset but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase balanced state in about 60 ms after the fault onset at the three-phase system.