• Title/Summary/Keyword: Single restoration

Search Result 354, Processing Time 0.035 seconds

Development of Load Duration Curve Methodology for TMDL Evaluation (오염총량평가를 위한 부하지속곡선 개발 및 적용)

  • Kang, Du-Kee;Kang, Soon-Ku;Kim, Sang-Dan;Shin, Hyun-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.652-656
    • /
    • 2007
  • The major streams in South Korea have established the TMDL(Total Maximum Daily Loads) regulation for just 4 years. Traditional concepts in water quality management in South Korea are based upon the selection of a design streram flow which is 10-year averged flow exeedance probability 75%(Q275). That is, a single flow value based upon average long term flow conditions is chosen for application in dilution calculations, permit design, water quality modeling, etc. While these TMDLs seems to satisfy the requirement of the target water quality regulations, they have contributed little to any watershed/waterbody assessment and restoration plans. These types of TMDLs do little to characterize the problems the TMDLs are intended to address. For TMDLs to be more beneficial in the assessment and implementation process, TMDLs should reflect adequate water quality across flow conditions rather than at a single flow value such as average daily flow. In this paper, we developed LDC (load duration curve) methodology for theevaluation of Korean TMDL evaluation based on watershed scaled, physically based on SWAT(Soil and Water Assessment Tool) model.

  • PDF

Real-time Fluorescence Lifetime Imaging Microscopy Implementation by Analog Mean-Delay Method through Parallel Data Processing

  • Kim, Jayul;Ryu, Jiheun;Gweon, Daegab
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.6-13
    • /
    • 2016
  • Fluorescence lifetime imaging microscopy (FLIM) has been considered an effective technique to investigate chemical properties of the specimens, especially of biological samples. Despite of this advantageous trait, researchers in this field have had difficulties applying FLIM to their systems because acquiring an image using FLIM consumes too much time. Although analog mean-delay (AMD) method was introduced to enhance the imaging speed of commonly used FLIM based on time-correlated single photon counting (TCSPC), a real-time image reconstruction using AMD method has not been implemented due to its data processing obstacles. In this paper, we introduce a real-time image restoration of AMD-FLIM through fast parallel data processing by using Threading Building Blocks (TBB; Intel) and octa-core processor (i7-5960x; Intel). Frame rate of 3.8 frames per second was achieved in $1,024{\times}1,024$ resolution with over 4 million lifetime determinations per second and measurement error within 10%. This image acquisition speed is 184 times faster than that of single-channel TCSPC and 9.2 times faster than that of 8-channel TCSPC (state-of-art photon counting rate of 80 million counts per second) with the same lifetime accuracy of 10% and the same pixel resolution.

INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES ACCORDING TO TREATMENT OF DENTIN SURFACE OF CERVICAL ABRASION LESION (치경부 마모병소의 상아질 표면처리 방식에 따른 상아질과 접착제 간의 계면 양상)

  • Lee, Yong-Hee;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.51-63
    • /
    • 2001
  • In order to know the effect of dentin bonding agents on the restoration of cervical abrasion, Scotchbond Multipurpose Single Bond and Clearfil Liner Bond 2 were used in 51 teeth with abrasion lesion and normal teeth. The surface structure and dentinal tubules of acid etched dentin and resin replica were examined using scanning electron microscopy. The interfacial morphology between dentin and adhesives was investigated by confocal laser scanning microscopy. Following results were obtained. 1. The hybrid layer and resin tag of the dentin showing cross-sectional surface of dentinal tubules are thicker and longer than those of dentin showing oblique surface of dentinal tubules. 2. The sclerotic cast was frequently observed in dentinal tubule, and the cast looked like cuboidal or rhomboidal-shaped crystals clumped from outer side to inner side. 3. The formation of hybrid layer and resin tag was the most prominent in Scotchbond Multipurpose group, whereas Clearfil Liner Bond 2 group showed very poor formation. The formation of hybrid layer and resin tag in Single Bond group was less than Scotchbond Multipurpose group.

  • PDF

The study on success rate of single implant replacing the mandibular first and second molars (하악 제1, 2대구치 단일 임플란트의 생존율에 관한 연구)

  • Jung, Taek-Gyun;Paeng, Joon-Young;Cho, Jin-Hyun;Lee, Sang-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.252-260
    • /
    • 2013
  • Purpose: After the introduction of concept of osteointegration, dental implantology have been successful procedure in the dental field. Recently, it has shown successful results when used to restore single tooth missing. Considering the difference in bone quality of the mandible and maxilla, and the increased occlusal force in the posterior region, the success rates in each region may be different. In this study, success rates of single implants placed in the mandibular first and second molar areas were analyzed. Materials and methods: The subjects were patients (284 patients, 308 implants) who had been operated with single implant installation from 2002 to 2009 in seven dental clinics in Daegu city. One hundred sixty eight implants were placed in the mandibular 1st molar and 140 implants were placed in the mandibular 2nd molar. They were analyzed according to implant site, age, sex, length and diameter. Results: The survival rates of single implant of this study were 97.6% in the mandibular 1st molar and 92.9% in the mandibular 2nd molar. In the mandibular 1st molar, 4 implants were failed. In the mandibular, 2nd molar, 10 implants were failed. Conclusion: The restoration of the mandibular 1st molar using single implant was found to be clinically acceptable treatment and showed higher survival rate than mandibular 2nd molar single implant. Single implant in mandibular 2nd molar needs careful consideration of poor bone quality, risk of overloading and anatomical structure of the mandible.

EFFECT OF INTERMEDIATE RESIN HYDROPHILICITY ON BOND STRENGTH OF SINGLE STEP ADHESIVE (중간레진의 친수성이 상아질 접착에 미치는 영향)

  • Kim, Yong-Sung;Park, Sang-Hyuk;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.445-458
    • /
    • 2007
  • The purpose of this study was to evaluate the bond strength of a new Single step system with different curing mode composites, and to evaluate the effect of the intermediate resins which have different hydrophilicity on bonding ability by means of the micro shear bond testing and TEM examination for the adhesive interface. The adhesive used in this study was an experimental single step system (Bisco Inc., Schaumburg IL). Experimental groups were produced by using six kinds of intermediate resin having different hydrophilicity that was hydrophilic, hydrophobic and most hydrophobic resin and as filled or not after applying adhesive. Each experimental group was further divided into two subgroups whether the adhesive was light cured or not. Dual cured composite (Bis Core, Bisco Ltd., Schaumburg, IL) was placed on the adhesive layer as light cure or self cure mode. The results or bond strength were statistically analyzed using one way ANOVA and multiple comparisons are made using Tukey's test at ${\alpha}\;<\;0.05$ level. The results of this study were as follows ; 1. The application of intermediate resin did not increase the bond strength for light cured composite. 2. The bond strength of an experimental adhesive with self cured composite was significantly increased by the application of intermediate resin layer. 3. The bond strength of adhesive was irrespective of the cure or not of itself before intermediate resin layer applied. 4. As applied hydrophilic resin layer was, the initial bond strength was higher than both hydrophobic and most hydrophobic one used but there was no significance. Using a single step adhesive with dual/self cured composite, the incompatibility between both of them should be solved by the application of intermediate hydrophobic resin to reduce the adhesive permeability. However, Single step adhesive can be used in the light cured composite restoration without any decrease of the initial bond strength.

Diagnosis of Esthetic treament (심미치료의 진단을 부탁해)

  • Paek, Jang Hyun
    • The Journal of the Korean dental association
    • /
    • v.54 no.1
    • /
    • pp.8-15
    • /
    • 2016
  • To improve esthetics and gain beautiful smile, the maxillary anterior dentition is crucial. Through alteration of height, arrangement or color of the maxillary incisor, we can rehabilitate the esthetic smile. The perception of dental esthetics is highly subjective. Personal perceptions or judgement of dental esthetics is highly related with each individual's experience and social and cultural environment. However, there have been many efforts to establish the criteria for generally accepted esthetic norm, in order to increase the predictability of restorative treatment. For maxillary anterior restoration, not only a single tooth, but also the compositions around tooth such as facial form, lips and gum and their relationships have to be considered to create harmonious smile. It can be determined as esthetic restorations when in consonance with facial form and structures that frame the restorations. In this review article, several guidelines that are generally accepted and useful to assess the esthetics and communicate with patients and technicians will be discussed.

  • PDF

Image Restoration in Digital Radiography Using Dual Sensor Wiener Filer (이중센서 위너필터를 이용한 디지탈 라디오 그라피 영상 복원)

  • Lee, Tae-Soo;Park, Kwang-Suk;Min, Byoumg-Goo;Lim, Jeong-Gee;Han, Man-Chung
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.293-302
    • /
    • 1989
  • A Dual Sensor Wiener Filter technique was used to improve the image quality of the scanning type digital radiographic system (resolution and SNR). In this method, two images were acquried simultaneously using two sensors with high and low resolution and SNR values. Using the cross Power spectrum between dual sensor outputs of the same chest radiographic image. we design a new type of Wiener Filter and implement it with fast algorithm. We compared the performance of this new dual sensor filter with conventional single sensor filters (Wiener Filter and Parametric Projec- tion Filter) . In simulation studies, it is shown that this new method has SNR improvement of 1-3 dB better than conventional filters.

  • PDF

The Development of Application Programs for Optimal Feeder Operation Through Distribution Automatic System

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jeong, Mi-Ae
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.42-47
    • /
    • 2004
  • This paper presents the various application programs for the Distribution Automation System (DAS) of the Korea Electric Power Corporation (KEPCO)'s distribution system. These programs are developed to allow for optimal operation in the areas of feeder automation, relay coordination, loss minimization and so on. They are single line diagram auto creation programs for the feeder, service restoration program, protection coordination program, data error detection program, and optimal network reconfiguration program. The details of these programs are presented for validity and effectiveness.

THE CONSTRUCTION METHOD OF IN-CERAM SPINELL CROWN AND ITS CLINICAL APPLICATION (In-Ceram Spinell Crown의 제작법과 임상적 응용)

  • Jo, Byung-Woan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.18-31
    • /
    • 1997
  • By the concerns of esthetic restoration were increased recently. many all ceramic crowns were developed. But they except In-Ceram Alumina were used only single crown. In-Ceram Alumina, developed by Dr. Sadon, was revealed to have high flexural Strength(450MPa). So it could be used not only anterior bridges but also posterior bridges. But In-Ceram Alumina was seen to be opaque, a little green color in transillumination light by high content of alumina oxide(85%). So new all ceramics with high strength and high translucence were needed. Spinell($MgAl_2O_3$) have a high melting point, high flexural strength, low heat conductivity, high light conductivity. In-Ceram Spinell offers glasslike light transmission by using the spinell cores instead of the alumina cores. And they have a high translucency like to natural tooth, an excellent margin integrity and a high strength(350MPa). The purposes of this study are 1) to know about the construction method of In-Ceram Spinell System, 2) to investigate the its clinical possibiliy through patients and literature reviews.

  • PDF

Panfacial Bone Fracture and Medial to Lateral Approach

  • Kim, Jiye;Choi, Jin-Hee;Chung, Yoon Kyu;Kim, Sug Won
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.4
    • /
    • pp.181-185
    • /
    • 2016
  • Panfacial bone fracture is challenging. Even experienced surgeons find restoration of original facial architecture difficult because of the severe degree of fragmentation and loss of reference segments that could guide the start of facial reconstruction. To restore the facial contour, surgeons usually follow a general sequence for panfacial bone reduction. Among the sequences, the bottom-to-top and outside-in sequence is reported to be the most widely used in recent publications. However, a single sequence cannot be applied to all cases of panfacial fractures because of the variations in panfacial bone fracture patterns. In this article, we intend to find the reference and discuss the efficacy of inside-out sequence in facial bone fracture reconstruction.