• 제목/요약/키워드: Single gamma

검색결과 659건 처리시간 0.025초

Comparison of geometrical methods to identify CME 3-D structures

  • Lee, Harim;Moon, Yong-Jae;Na, Hyeonock;Jang, Soojeong
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.73-73
    • /
    • 2014
  • Several geometrical models (e.g., cone and flux rope models) have been suggested to infer 3-D parameters of CMEs using multi-view observations (STEREO/SECCHI) and single-view observations (SOHO/LASCO). To prepare for when only single view observations are available, we have made a test whether the cone model parameters from single-view observations are consistent with those from multi-view ones. For this test, we select 35 CMEs which are identified as CMEs, whose angular widths are larger than 180 degrees, by one spacecraft and as limb CMEs by the other ones. For this we use SOHO/LASCO and STEREO/SECCHI data during the period from 2010 December to 2011 July when two spacecraft were separated by $90{\pm}10$ degrees. In this study, we compare 3-D parameters of these CMEs from three different methods: (1) a triangulation method using the STEREO/SECCHI and SOHO/LASCO data, (2) a Graduated Cylindrical Shell (GCS) flux rope model using the STEREO/SECCHI data, and (3) an ice cream cone model using the SOHO/LASCO data. The parameters used for comparison are radial velocities, angular widths and source location (angle ${\gamma}$ between the propagation direction and the plan of the sky). We find that the radial velocities and the ${\gamma}$-values from three methods are well correlated with one another (CC > 0.8). However, angular widths from the three methods are somewhat different. The correlation coefficients are relatively not good (CC > 0.4). We also find that the correlation coefficients between the locations from the three methods and the active region locations are larger than 0.9, implying that most of the CMEs are radially ejected.

  • PDF

방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구 (Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging)

  • 송근영;황영관;이남호;나준희
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1535-1541
    • /
    • 2019
  • 방사선 사고 지역 및 제염이 필요한 지역에서의 안전하고 신속한 제염작업을 진행하기 위해서는 방사선 오염원에 대한 다양한 정보 획득이 필요하다. 특히 방사선원의 정확한 위치와 분포 정보의 파악은 신속한 후속 조치 및 오염원 제거를 위해 반드시 필요하며, 작업자의 방사선 피폭을 최소화할 수 있다. 방사선원의 위치와 분포 정보를 획득하기 위해서는 방사선 분포 탐지 장치를 사용한다. 방사선 분포 탐지 장치의 경우 일반적으로 탐지 센서 부가 단일 센서로 구성되며, 단일 센서의 물리적 한계로 인해 탐지 범위가 제한되는 문제점이 있다. 본 논문에서는 방사선 오염 분포 영상화 장치에 사용되는 단일 센서의 탐지 감도 제어를 위하여 보정 검출기를 적용하였으며, 이를 통해 제한적이었던 선량률 탐지 범위를 향상하였다. 또한 감마선 조사 시험을 통해 방사선 분포 탐지 범위의 개선을 확인하였다.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Investigation of 180W separation by transient single withdrawal cascade using Salp Swarm optimization algorithm

  • Morteza Imani;Mahdi Aghaie
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1225-1232
    • /
    • 2023
  • The 180W is the lightest isotope of Tungsten with small abundance ratio. It is slightly radioactive (α decay), with an extremely long half-life. Its separation is possible by non-conventional single withdrawal cascades. The 180W is used in radioisotopes production and study of metals through gamma-ray spectroscopy. In this paper, single withdrawal cascade model is developed to evaluate multicomponent separation in non-conventional transient cascades, and available experimental results are used for validation. Numerical studies for separation of 180W in a transient single withdrawal cascade are performed. Parameters affecting the separation and equilibrium time of cascade such as number of stages, cascade arrangements, feed location and flow rate for a fixed number of gas centrifuges (GC) are investigated. The Salp Swarm Algorithm (SSA) as a bio-inspired optimization algorithm is applied as a novel method to minimize the feed consumption to obtain desired concentration in the collection tank. Examining different cascade arrangements, it is observed in arrangements with more stages, the separation is further efficient. Based on the obtained results, with increasing feed flow rate, for fixed product concentration, the cascade equilibrium time decreases. Also, it is shown while the feed location is the farthest stage from the collection tank, the separation and cascade equilibrium time are well-organized. Finally, using SSA optimal parameters of the cascade is calculated, and optimal arrangement to produce 5 gr of 180W with 90% concentration in the tank, is proposed.

Expression of peroxisome proliferator activated receptor gamma in the neuronal cells and modulation of their differentiation by PPAR gamma agonists

  • Hong, Jin-Tae
    • 한국환경성돌연변이발암원학회:학술대회논문집
    • /
    • 한국환경성돌연변이발암원학회 2002년도 Molecular and Cellular Response to Toxic Substances
    • /
    • pp.14-40
    • /
    • 2002
  • 15-Deoxy-${\Delta}^{12, 14}$-prostaglandin $J_2$ (15-deoxy-$PGJ_2$), a naturally occurring ligand activates the peroxisome proliferator-activated $receptor-{\gamma}(PPAR-{\gamma}$). Activation of $PPAR-{\gamma}$ has been found to induce cell differentiation such as adipose cell and macrophage. Here it was investigated whether 15-deoxy-$PGJ_2$ has neuronal cell differentiation and possible underlying molecular mechanisms. Dopaminergic differentiating PC 12 cells treated with 15-deoxy-$PGJ_2$ (0.2 to 1.6 ${\mu}M$) alone showed measurable neurite extension and expression of neurofilament, markers of cell differentiation. However much greater extent of neurite extension and expression of neurofilament was observed in the presence of NGF (50 ng/ml). In parallel with its increasing effect on the neurite extension and expression of neurofilament, 15-deoxy-$PGJ_2$ enhanced NGF-induced p38 MAP kinase expression and its phosphorylation in addition to the activation of transcription factor AP-1 in a dose dependent manner. Moreover, pretreatment of SD 203580, a specific inhibitor of p38 MAP kinase inhibited the promoting effect of 15-deoxy-$PGJ_2$(0.8 ${\mu}M$) on NGF-induced neurite extension. This inhibition correlated well with the ability of SB203580 to inhibit the enhancing effect of 15-deoxy-$PGJ_2$ on the expression of p38 MAP kinase and activation of AP-1, The promoting ability of 15-deoxy-$PGJ_2$ did not occur through $PPAR-{\gamma}$, as synthetic PPAR-${\gamma}$ agonist andantagonist did not change the neurite promoting effect of 15-deoxy-PGJ$_2$. In addition, contrast to other cells (embryonic midbrain and SK-N-MC cells), $PPAR-{\gamma}$ was not expressed in PC-12 cells. Other structure related prostaglandins, PGD$_2$ and $PGE_2$ acting via a cell surface G-protein-coupled receptor (GPCR) did not increase basal or NGF-induced neurite extension. Moreover, GPCR (EP and DP receptor) antagonists did not alter the promoting effect of f 5-deoxy-$PGJ_2$ on neurite extension and activation of p38 MAP kinase, suggesting that the promoting effect of 15-deoxy-$PGJ_2$ may not be mediated GPCR. These data demonstrate that activation of p38 MAP kinase in conjunction with AP-1 single pathway may be important in the promoting activity of 15-deoxy-$PGJ_2$ cells.

  • PDF

Repeat Stereotactic Radiosurgery for Recurred Metastatic Brain Tumors

  • Kim, In-Young;Jung, Shin;Jung, Tae-Young;Moon, Kyung-Sub;Jang, Woo-Youl;Park, Jae-Young;Song, Tae-Wook;Lim, Sa-Hoe
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권5호
    • /
    • pp.633-639
    • /
    • 2018
  • Objective : We investigated the outcomes of repeat stereotactic radiosurgery (SRS) for metastatic brain tumors that locally recurred despite previous SRS, focusing on the tumor control. Methods : A total of 114 patients with 176 locally recurring metastatic brain tumors underwent repeat SRS after previous SRS. The mean age was 59.4 years (range, 33 to 85), and there were 68 male and 46 female patients. The primary cancer types were non-small cell lung cancer (n=67), small cell lung cancer (n=12), gastrointestinal tract cancer (n=15), breast cancer (n=10), and others (n=10). The number of patients with a single recurring metastasis was 95 (79.8%), and another 19 had multiple recurrences. At the time of the repeat SRS, the mean volume of the locally recurring tumors was 5.94 mL (range, 0.42 to 29.94). We prescribed a mean margin dose of 17.04 Gy (range, 12 to 24) to the isodose line at the tumor border primarily using a 50% isodose line. Results : After the repeat SRS, we obtained clinical and magnetic resonance imaging follow-up data for 84 patients (73.7%) with a total of 108 tumors. The tumor control rate was 53.5% (58 of the 108), and the median and mean progression-free survival (PFS) periods were 246 and 383 days, respectively. The prognostic factors that were significantly related to better tumor control were prescription radiation dose of 16 Gy (p=0.000) and tumor volume less than both 4 mL (p=0.001) and 10 mL at the repeat SRS (p=0.008). The overall survival (OS) periods for all 114 patients after repeat SRS varied from 1 to 56 months, and median and mean OS periods were 229 and 404 days after the repeat SRS, respectively. The main cause of death was systemic problems including pulmonary dysfunction (n=58, 51%), and the identified direct or suspected brain-related death rate was around 20%. Conclusion : The tumor control following repeat SRS for locally recurring metastatic brain tumors after a previous SRS is relatively lower than that for primary SRS. However, both low tumor volume and high prescription radiation dose were significantly related to the tumor control following repeat SRS for these tumors after previous SRS, which is a general understanding of primary SRS for metastatic brain tumors.

정규압밀 점토 지반에서 매입말뚝의 수평거동에 관한 모형 실험 연구 (Model Testing on the Behavior of Laterally Loaded Pile in NC Clay Soils)

  • 김병탁;이상웅;김영수
    • 한국지반공학회지:지반
    • /
    • 제14권5호
    • /
    • pp.39-52
    • /
    • 1998
  • 본 논문은 정규압밀된 점성토 지반에서 강관 매입 말뚝의 수평 거동에 영향을 미치는 여러인자들 중에서 말뚝의 근입길이, 지반조건(건조단위 중량 $\gamma_4$), 말뚝 두부의 구속조건의 영향에 관하여 모형실험을 수행하였으며, 이러한 영향을 정량화 할 수 있는 경첩식을 그 결과들로부터 얻었다. 모형실험에 사용한 지반은 3종류의 정규압밀 점토이다. 2종류의 말뚝 근입길이와 말뚝 두부의 고정 자유조건의 모형실험결과들에 의하여 수평하중-변위 관계는 $\gamma_d/\gamma_{dmax}$=0.84 이하에서 완전 탄소성체의 거동형상을 보일 것으로 나타났으며, 각 실험에서 최대 수평하중(Q--) 이후의 수평하중 감소는 상당한 시간 의존성을 보였다. 본 연구에서는 수평 하중-변위관계(logo-logy/D)와 최대 휨 모멘트-변위관계($loaM_{max}$.-.-logy/D)에서 각각 구한 항복 수평하중(Qy)과 항복 최대 휭 모멘트(My)가 직선적인 관계로 밝혀졌다. Relaxation에 의한 수평하 중은 모형실험 결과들로부터 시간을 변수로 한 지수 함수식으로 회귀분석 하였다. 수평 극한하중과 항복하중에 대한 지반조건의 영향은 $\gamma_4$$/\gamma_{dmax}$의 변수로 한 지수함수식으로 모델화 하였으며, Broms와 Budhu et at.에 의한 결과와의 비교에서 예측결과가 26-78%정도 과대평가 되었다. 수평하중-변위 관계에 대한 말뚝 두부의 고정조건 영향에서 $Q_{mxed}/Q_{free}$-y/D의 관계는 상당히 비선형적으로 나타났으며, yiD를 변수로 한 지수함수식으로 모델화하였다.

  • PDF

소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가 (Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System)

  • 양묘근;곽철은;심용걸;김희중;최용;정준기;이명철;고창순
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

OPTIMAL UTILIZATION OF SERVICE FACILITY FOR A k-OUT-OF-n SYSTEM WITH REPAIR BY EXTENDING SERVICE TO EXTERNAL CUSTOMERS IN A RETRIAL QUEUE

  • Krishnamoorthy, A.;Narayanan, Viswanath C.;Deepak, T.G.
    • Journal of applied mathematics & informatics
    • /
    • 제25권1_2호
    • /
    • pp.389-405
    • /
    • 2007
  • In this paper, we study a k-out-of-n system with single server who provides service to external customers also. The system consists of two parts:(i) a main queue consisting of customers (failed components of the k-out-of-n system) and (ii) a pool (of finite capacity M) of external customers together with an orbit for external customers who find the pool full. An external customer who finds the pool full on arrival, joins the orbit with probability ${\gamma}$ and with probability $1-{\gamma}$ leaves the system forever. An orbital customer, who finds the pool full, at an epoch of repeated attempt, returns to orbit with probability ${\delta}\;(<\;1)$ and with probability $1-{\delta}$ leaves the system forever. We compute the steady state system size probability. Several performance measures are computed, numerical illustrations are provided.

감마분포 처리의 최대 척도모수 선택에 관한 제거형 이단 선택방법 (A two-stage elimination type procedure for selecting the largest gamma scale parameter)

  • 김순기
    • 응용통계연구
    • /
    • 제1권2호
    • /
    • pp.27-33
    • /
    • 1987
  • 감마분포에 따르는 K($\geq$2)개의 처리들 중에서 최대 척도모수를 갖는 처리를 선택하는 제거형 이단 선택방법을 제안하고 주어진 $(\delta^*, p^*)$에 대하여 Kim(1985)이 제안한 선택확률의 하한을 만족할때 설계상수(nr, mr, c)와 총실험횟수의 평균을 Monte Carlo 방법으로 구하였다. 또한 총실험횟수를 작게한다는 점에서 일단 선택방법보다 유용함을 밝혔다.