• Title/Summary/Keyword: Single file

Search Result 254, Processing Time 0.033 seconds

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.

PHP File Upload implementation of infinite using a single Database Field (단일 Database Field를 이용한 PHP 무한 File Upload 구현)

  • Hwang, Ki-Hwan;Byun, Ki-Hwan;Lee, Jie-Young
    • The Journal of Information Technology
    • /
    • v.12 no.2
    • /
    • pp.49-55
    • /
    • 2009
  • Currently the Web, multiple files in the Client to upload to the server of the multi-upload method, files are stored in specific folders on the server, the file name field in DB(Database Field) stored in a way that the process has been widely utilized. Therefore, a minimum number of file upload as many file names in the Database and the Table should be created in the field, but also a variable number of files can be uploaded has no limits. In this paper we proposed the new method that files to be uploaded to the server, you can upload a limited number of files, nor due to upload files to reduce load on the database to improve the processing speed of a single field using a multi-method file uploads using PHP directly implemented

  • PDF

Intraoperative discomfort associated with the use of a rotary or reciprocating system: a prospective randomized clinical trial

  • Gomes, Aline Cristine;Soares, Adriana Jesus;Souza, Erick M;Zaia, Alexandre Augusto;Silva, Emmanuel Joao Nogueira Leal
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.140-145
    • /
    • 2017
  • Objectives: The aim of this randomized, controlled, prospective clinical study was to evaluate patients' intraoperative discomfort during root canal preparations in which either multi-file rotary (Mtwo) or single-file reciprocating (Reciproc) systems were used. Materials and Methods: Fifty-five adult patients, aged between 25 and 69 years old, with irreversible pulpitis or pulp necrosis participated in this study. Either the mesiobuccal or the distobuccal canals for maxillary molars and either the mesiobuccal or the mesiolingual canals for mandibular molars were randomly chosen to be instrumented with Mtwo multi-file rotary or Reciproc single-file reciprocating systems. Immediately after each canal instrumentation under anesthesia, patient discomfort was assessed using a 1 - 10 visual analog scale (VAS), ranging from 'least possible discomfort' (1) to 'greatest possible discomfort' (10). The Wilcoxon signed-rank test was used to determine significant differences at p < 0.05. Results: Little intraoperative discomfort was found in all cases. No statistically significant differences in intraoperative discomfort between the 2 systems were found (p = 0.660). Conclusions: Root canal preparation with multi-file rotary or single-file reciprocating systems had similar and minimal effects on patients' intraoperative discomfort.

Co-Writing Multiple Files Based on Directory Locality for High Performance of Small File Writes (디렉토리 지역성을 활용한 작은 파일들의 모아 쓰기 기법)

  • Lee, Kyung-Jae;Ahn, Woo-Hyun;Oh, Jae-Won
    • The KIPS Transactions:PartA
    • /
    • v.15A no.5
    • /
    • pp.275-286
    • /
    • 2008
  • Fast File System(FFS) utilizes large disk bandwidth to improve the write performance of large files. One way to improve the performance is to write multiple blocks of a large file at a single disk I/O through the disk bandwidth. However, rather than disk bandwidth, the performance of small file writes is limited by disk access times significantly impacted by disk movements such as disk seek and rotation because FFS writes each of small files at a single disk write. We propose CW-FFS (Co-Writing Fast File System) to improve the write performance of small files by minimizing the disk movements that are needed to write small files to disks. Its key technique called co-writing scheme is to dynamically collect multiple small files named by a given directory and then write them at a single disk I/O to contiguous disk locations. Co-writing several small files at a single disk I/O reduces multiple disk movements that are needed for small file writes to one single disk movement, thus increasing the overall write performance of write-intensive applications. Furthermore, a file allocation scheme is introduced to prevent co-writing scheme from having a negative impact on disk spatial locality of small files named by a given directory. The measurement of our technique implemented in the OpenBSD 4.0 shows that CW-FFS increases the performance of small file writes over FFS in the range from 5 to 35% in the Postmark benchmark.

Efficient Peer-to-Peer File Sharing Using Network Coding in MANET

  • Lee, Uichin;Park, Joon-Sang;Lee, Seung-Hoon;Ro, Won-W.;Pau, Giovanni;Gerla, Mario
    • Journal of Communications and Networks
    • /
    • v.10 no.4
    • /
    • pp.422-429
    • /
    • 2008
  • Mobile peer-to-peer (P2P) systems have recently got in the limelight of the research community that is striving to build efficient and effective mobile content addressable networks. Along this line of research, we propose a new peer-to-peer file sharing protocol suited to mobile ad hoc networks (MANET). The main ingredients of our protocol are network coding and mobility assisted data propagation, i.e., single-hop communication. We argue that network coding in combination with single-hop communication allows P2P file sharing systems in MANET to operate in a more efficient manner and helps the systems to deal with typical MANET issues such as dynamic topology and intermittent connectivity as well as various other issues that have been disregarded in previous MANET P2P researches such as addressing, node/user density, non-cooperativeness, and unreliable channel. Via simulation, we show that our P2P protocol based on network coding and single-hop communication allows shorter file downloading delays compared to an existing MANET P2P protocol.

Dynamic File Migration And Mathematical model in Distributed Computer Systems (분산 시스템에서 동적 파일 이전과 수학적 모델)

  • Moon, Won Sik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.3
    • /
    • pp.35-40
    • /
    • 2014
  • Many researches have been conducted to achieve improvement in distributed system that connects multiple computer systems via communication lines. Among others, the load balancing and file migration are considered to have significant impact on the performance of distributed system. The dynamic file migration algorithm common in distributed processing system involved complex calculations of decision function necessary for file migration and required migration of control messages for the performance of decision function. However, the performance of this decision function puts significant computational strain on computer. As one single network is shared by all computers, more computers connected to network means migration of more control messages from file migration, causing the network to trigger bottleneck in distributed processing system. Therefore, it has become imperative to carry out the research that aims to reduce the number of control messages that will be migrated. In this study, the learning automata was used for file migration which would requires only the file reference-related information to determine whether file migration has been made or determine the time and site of file migration, depending on the file conditions, thus reflecting the status of current system well and eliminating the message transfer and additional calculation overhead for file migration. Moreover, mathematical model for file migration was described in order to verify the proposed model. The results from mathematical model and simulation model suggest that the proposed model is well-suited to the distributed system.

Effects of the endodontic access cavity on apical debris extrusion during root canal preparation using different single-file systems

  • Tufenkci, Pelin;Yilmaz, Koray;Adiguzel, Mehmet
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.33.1-33.10
    • /
    • 2020
  • Objectives: This study was conducted to evaluate the effects of traditional and contracted endodontic cavity (TEC and CEC) preparation with the use of Reciproc Blue (RPC B) and One Curve (OC) single-file systems on the amount of apical debris extrusion in mandibular first molar root canals. Materials and Methods: Eighty extracted mandibular first molar teeth were randomly assigned to 4 groups (n = 20) according to the endodontic access cavity shape and the single file system used for root canal preparation (reciprocating motion with the RCP B and rotary motion with the OC): TEC-RPC B, TEC-OC, CEC-RPC B, and CEC-OC. The apically extruded debris during preparation was collected in Eppendorf tubes. The amount of extruded debris was quantified by subtracting the weight of the empty tubes from the weight of the Eppendorf tubes containing the debris. Data were analyzed using 1-way analysis of variance with the Tukey post hoc test. The level of significance was set at p < 0.05. Results: The CEC-RPC B group showed more apical debris extrusion than the TEC-OC and CEC-OC groups (p < 0.05). There were no statistically significant differences in the amount of apical debris extrusion among the TEC-OC, CEC-OC, and TEC-RPC B groups. Conclusions: RPC B caused more apical debris extrusion in the CEC groups than did the OC single-file system. Therefore, it is suggested that the RPC B file should be used carefully in teeth with a CEC.

An Analysis on the Performance of TRIM Commands on SSDs and its Application to the Ext4 File System (SSD에서의 TRIM 명령어 처리 성능 분석 및 Ext4 파일 시스템으로의 적용)

  • Son, Hyobong;Lee, Youngjae;Kim, Yongserk;Kim, Jin-Soo
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • In this paper, we analyze the performance of the TRIM commands on various SSDs and, based on our analysis results, we enhance the performance of these TRIM commands in the Ext4 file system. We observed that the performance of the TRIM commands improves as the size of the LBA-range increases, the sector number is aligned and continuous or more LBA-ranges are notified via a single TRIM command. However, although the performance is better when multiple LBA-ranges are informed by a single TRIM command, the Ext4 file system issues a single TRIM command for every LBA-range. In this paper, we modify the Ext4 file system to convey at most 64 LBA-ranges per TRIM command. Evaluations through Filebench show that the performance of file deletion operations is improved by up to 35%.

Authoring Tool of Musical Slide Show MAF Contents

  • Sabirin Muhammad Syah Houari;Kim Mun-Churl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.289-295
    • /
    • 2006
  • The Musical Slide Show MAF, which currently being standardized by MPEG, conveys the concept of combining several established standard technologies in a single file format. It defines the format of packing up MP3 audio data, along with MPEG-7 Simple Metadata Profile and MPEG-21 Digital Item Declaration metadata; with JPEC images and optional text, and synchronizes them all together to create a slideshow of JPEC image data associated to MP3 audio data during the audio playback. The implementation of Musical Slide Show MAF can be a music karaoke file where users can sing along while listening to the music, view the JPEG slideshow and reading the lyrics; or a story-telling file where users can listen to the narrated story by looking at the related illustration slideshow of the story In this paper we present the tool to producing the Musical Slide Show MAF contents. Regardless the knowledge of user on the MAF file format, the authoring tool simplify the manner of packaging several multimedia contents into single file.

  • PDF

Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth

  • Saleh, Abdulrahman Mohammed;Tavanafar, Saeid;Vakili-Gilani, Pouyan;Al Sammerraie, Noor Jamal;Rashid, Faahim
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.222-226
    • /
    • 2013
  • Objectives: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. Materials and Methods: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. Results: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. Conclusions: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.