• 제목/요약/키워드: Single chamber fuel Cell

검색결과 18건 처리시간 0.034초

20W급 휴대용 연료전지 시스템 설계 (System Design for 20W Portable Fuel Cell)

  • 지영석;고정식;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.161-165
    • /
    • 2007
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells. In addition they can be built as a self/non-reformable system and single/dual chamber system. So We evaluated some types of SOFC theoretically, and compared the results from the fuel and performance efficiency point of view.

  • PDF

지르코니아 전해질을 이용한 단실형 고체산화물 연료전지의 전기화학 특성 (The Electrochemical Property of the Single-Chamber Solid Oxide Fuel Cell Based on a Zirconia Electrolyte)

  • 박희정;주종훈;양재교;진연호;이규형
    • 한국전기전자재료학회논문지
    • /
    • 제29권8호
    • /
    • pp.510-515
    • /
    • 2016
  • Single-chamber solid oxide fuel cells (SC-SOFCs) consist of only one gas chamber, in which both the anode and the cathode are exposed to the same fuel-oxidant mixture. Thus, this configuration shows good thermal and mechanical resistance and allows rapid start-up and -down. In this study, the unit cell consisting of $La_{0.8}Sr_{0.2}MnO_3$ (cathode) / $Zr_{0.84}Y_{0.16}O_{2-x}$ (electrolyte) / $Ni-Zr_{0.84}Y_{0.16}O_{2-x}$ (anode) was fabricated and its electrochemical property was investigated as a function of temperature and the volume ratio of fuel and oxidant for SC-SOFCs. Impedance spectra were also investigated in order to figure out the electrical characteristics of the cell. As a result, the cell performance was governed by the polarization resistances of the electrodes. The cell exhibited an acceptable cell-performance of $86mW/cm^2$ at $800^{\circ}C$ and stable performance for 3 hs under 0.7 V.

Methane-Air 혼합 Gas에서 구동하는 하니컴 형태의 SC-SOFC (Honeycomb-type Single Chamber SOFC Running on Methane-Air Mixture)

  • 박병탁;윤성필;김현재;남석우;한종희;임태훈;홍성안;이덕열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.306-309
    • /
    • 2005
  • One of the most critical issues in sol id oxide fuel cell (SOFC)running on hydrocarbon fuels is the risk of carbon formation from the fuel gas. The simple method to reduce the risk of carbon formation from the reactions is to add steam to the fuel stream, leading to the carbon gasification react ion. However, the addition of steam to fuel is not appropriate for the auxiliary power unit (APU) and potable power generation (PPG) systems due to an increase of complexity and bulkiness. In this regard, many researchers have focused on so-called 'direct methane' operation of SOFC, which works with dry methane without coking. However, coking can be suppressed only by the operation with a high current density, which may be a drawback especially for the APU and PPG systems. The single chamber fuel cell (SC-SOFC) is a novel simplification of the conventional SOFC into which a premixed fuel/air mixture is introduced. It relies on the selectivity of the anode and cathode catalysts to generate a chemical potential gradient across the cell. Moreover it allows compact and seal-free stack design. In this study, we fabricated honeycomb type mixed-gas fuel cell (MGFC) which has advantages of stacking to the axial direction and increasing volume power density. Honeycomb-structured SOFC with four channels was prepared by dry pressing method. Two alternative channels were coated with electrolyte and cathode slurry in order to make cathodic reaction sites. We will discuss that the anode supported honeycomb type cell running on mixed gas condition.

  • PDF

수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가 (Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell)

  • 장익황;하승범;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF

단위 셀간 성능편차 및 접속접안 강하 초소화를 위한 극소형 직접메탄올 연료전지 스택의 설계 및 제작 (MEMS-based Direct Methanol Fuel Cells and Their Stacks for the Reduction of Cell-to-Cell Deviation and Interconnection Voltage Drop)

  • 서영호;조영호
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.981-985
    • /
    • 2007
  • We present a MEMS-based portable Direct Methanol Fuel Cell (micro-DFMC), featured by a platinum sputtered microcolumn electrode and a built-in fuel chamber containing a limited amount of methanol fuel. Also presented is a micro-DMFC stack structure having a common electrolyte sandwiched by the microcolumn electrodes. The single cells with ME16 and PE16 electrodes show the maximum power densities of $31.04{\pm}0.29{\mu}W/cm^2$ and $9.75{\pm}0.29{\mu}W/cm^2$, respectively; thus indicating the microcolumn electrode (ME16) generates the power density (3.2 times) higher than the planar electrode (PE16). The single cell tests of ME16 and ME4 electrodes (Fig.8) show the maximum power of $31.04{\pm}0.29{\mu}W/cm^2$, and $25.23{\pm}2.7{\mu}W/cm^2$, respectively; thus demonstrating the increased window frame reduces the normalized standard power deviation (standard deviation over the average power). The normalized deviation of 0.11 in ME4 cell has been reduced to 0.01 in ME16 cell due to the increased window frames. The maximum power density of 4-cell stack is 15.7 times higher than that of the single cell. 4-cell stack produces the power capacity of 20.3mWh/g during 980min operation at the voltage of 450mV with the load resistance of $800{\Omega}$.

침지 및 직립 평판형 MFC 스택에서 전극연결 방식에 따른 전기발생량 비교 (Electricity Generations in Submerged-flat and Stand-flat MFC Stacks according to Electrode Connection)

  • 유재철;박영현;이태호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.589-593
    • /
    • 2016
  • 미생물연료전지(Microbial Fuel Cell; MFC)는 전기화학활성미생물로 불리는 미생물을 촉매로 이용하여, 유/무기물의 산화환원 반응을 통해서 전기에너지를 생산할 수 있는 장치이다. 단일 MFC에서 발생하는 낮은 전기생산량을 극복하기 위해, 다수의 형태의 MFC를 직렬 또는 병렬로 연결하는 방법이 연구되고 있다. 본 연구에서는 6개의 단위 막전극접합체(Separator Electrode Assembly; SEA)로 구성된 침지평판형과 직립평판형 MFC 스택을 운전하였다. 단위 MFC와 MFC 스택의 전기발생량을 비교하였으며, 이를 통해서 MFC의 최적 스택기술을 확보하기 위한 기초자료로 활용하고자 하였다. 모든 SEA가 산화전극부를 공유하고 있는 침지평판형 MFC의 경우, 직렬과 병렬을 함께 사용할 경우, 단일 연결 방식을 사용하는 것보다 전압의 손실이 더 크게 나타났으며, 단일 연결방법 중 병렬연결 하는 것이 손실을 최소화 할 수 있는 것으로 나타났다. 직립평판형 MFC의 경우, 산화전극부를 공유하고 있는 SEA만 직렬 연결할 경우에는 전압의 손실이 크게 나타났으며, 산화전극부를 공유하고 있는 SEA간에 병렬 연결 후, 병렬 연결된 SEA를 직렬연결하는 방식이 전압의 손실을 최소화 할 수 있을 것으로 나타났다.

패턴된 전극을 가진 표면 전도형 단실형 고체산화물 연료전지의 제조 (Fabrication of Co-Planar Type Single Chamber SOFC with Patterned Electrodes)

  • 안성진;김용범;문주호;이종호;김주선
    • 한국세라믹학회지
    • /
    • 제43권12호
    • /
    • pp.798-804
    • /
    • 2006
  • Co-planar type single chamber solid oxide fuel cell with patterned electrode on a surface of electrolyte has been fabricated by robo-dispensing method and microfluidic lithography. The cells were composed of NiO-GDC-Pd or NiO-SDC cermet anode, $(La_{0.7}Sr_{0.3})_{0.95}MnO_3$ cathode, and yttria stablized zirconia electrolyte. The cell performance at $900^{\circ}C$ was investigated as a function of electrode geometries, such as anode-to-cathode distance, numbers of electrode pairs. Relationship between OCV and I-V characteristics at the optimized operation condition was also studied by DC source meter under the mixed gas condition of methane, air, and nitrogen. An increase of anode-facing-cathode area leads to lower OCV due to intermixing between product gases of anode and cathode, which in turn decreases the oxygen partial pressure difference.

Effects of Ru Co-Sputtering on the Properties of Porous Ni Thin Films

  • Kim, Woo-Sik;Choi, Sun-Hee;Lee, Hae-Weon;Kim, Joo-Sun
    • 한국세라믹학회지
    • /
    • 제43권11호
    • /
    • pp.746-750
    • /
    • 2006
  • NiO films and Ru co-sputtered NiO films were deposited by reactive magnetron sputtering for micro-solid oxide fuel cell anode applications. The deposited films were reduced to form porous films. The reduction kinetics of the Ru doped NiO film was more sluggish than that of the NiO film, and the resulting microstructure of the former exhibited finer pore networks. The possibility of using the films for the anodes of single chamber micro-SOFCs was investigated using an air/fuel mixed environment. It was found that the abrupt increase in the resistance is suppressed in the Ru co-sputtered film, as compared to undoped film.

Determination of Microbial Growth by Protein Assay in an Air-Cathode Single Chamber Microbial Fuel Cell

  • Li, Na;Kakarla, Ramesh;Moon, Jung Mi;Min, Booki
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권7호
    • /
    • pp.1114-1118
    • /
    • 2015
  • Microbial fuel cells (MFCs) have gathered attention as a novel bioenergy technology to simultaneously treat wastewater with less sludge production than the conventional activated sludge system. In two different operations of the MFC and aerobic process, microbial growth was determined by the protein assay method and their biomass yields using real wastewater were compared. The biomass yield on the anode electrode of the MFC was 0.02 g-COD-cell/gCOD-substrate and the anolyte planktonic biomass was 0.14 g-COD-cell/g-COD-substrate. An MFC without anode electrode resulted in the biomass yield of 0.07 ± 0.03 g-COD-cell/g-CODsubstrate, suggesting that oxygen diffusion from the cathode possibly supported the microbial growth. In a comparative test, the biomass yield under aerobic environment was 0.46 ± 0.07 g-COD-cell/g-COD-substrate, which was about 3 times higher than the total biomass value in the MFC operation.