• Title/Summary/Keyword: Single Port

Search Result 483, Processing Time 0.024 seconds

Early Outcomes of Single-Port Video-Assisted Thoracic Surgery for Primary Spontaneous Pneumothorax

  • Kang, Do Kyun;Min, Ho Ki;Jun, Hee Jae;Hwang, Youn Ho;Kang, Min-Kyun
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.384-388
    • /
    • 2014
  • Background: Recently, single-port video-assisted thoracic surgery (VATS) has been proposed as an alternative to the conventional three-port VATS for primary spontaneous pneumothorax (PSP). The aim of this study is to evaluate the early outcomes of the single-port VATS for PSP. Methods: VATS was performed for PSP in 52 patients from March 2012 to March 2013. We reviewed the medical records of these 52 patients, retrospectively. Nineteen patients underwent the conventional three-port VATS (three-port group) and 33 patients underwent the single-port VATS (single-port group). Both groups were compared according to the operation time, number of wedge resections, amount of chest tube drainage during the first 24 hours after surgery, length of chest tube drainage, length of hospital stay, postoperative pain score, and postoperative paresthesia. Results: There was no difference in patient characteristics between the two groups. There was no difference in the number of wedge resections, operation time, or amount of drainage between the two groups. The mean lengths of chest tube drainage and hospital stay were shorter in the single-port group than in the three-port group. Further, there was less postoperative pain and paresthesia in the single-port group than in the three-port group. These differences were statistically significant. The mean size of the surgical wound was 2.10 cm (range, 1.6 to 3.0 cm) in the single-port group. Conclusion: Single-port VATS for PSP had many advantages in terms of the lengths of chest tube drainage and hospital stay, postoperative pain, and paresthesia. Single-port VATS is a feasible technique for PSP as an alternative to the conventional three-port VATS in well-selected patients.

Efficacy of Single-Port Video-Assisted Thoracoscopic Surgery Lobectomy Compared with Triple-Port VATS by Propensity Score Matching

  • Song, Kyung Sub;Park, Chang Kwon;Kim, Jae Bum
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.339-345
    • /
    • 2017
  • Background: In recent years, single-port video-assisted thoracoscopic surgery (VATS) for lobectomy in non-small cell lung cancer (NSCLC) patients has become increasingly common. The objective of this study was to compare the feasibility and safety of single-port and triple-port VATS lobectomy. Methods: A total of 73 patients with NSCLC who underwent VATS lobectomy from December 2011 to August 2016 were retrospectively reviewed, including 47 in the triple-port group and 26 in the single-port group. Statistical analysis was performed after propensity score matching. Patients were matched on a 1-to-1 basis. Results: Operative time and intraoperative blood loss in the triple-port group and the single-port group were similar ($189.4{\pm}50.8minutes$ vs. $205.4{\pm}50.6minutes$, p=0.259; $286.5{\pm}531.0mL$ vs. $314.6{\pm}513.1mL$, p=0.813). There were no cases of morbidity or mortality. No significant differences in complications or the total number of dissected lymph nodes were found between the 2 groups. In the single-port group, more mediastinal lymph nodes were dissected than in the triple-port group ($1.7{\pm}0.6$ vs. $1.2{\pm}0.5$, p=0.011). Both groups had 1 patient with bronchopleural fistula. Chest tube duration and postoperative hospital stay were shorter in the single-port group than in the triple-port group ($8.7{\pm}5.1days$ vs. $6.2{\pm}6.6days$, p=0.130; $11.7{\pm}6.1days$ vs. $9.5{\pm}6.4days$, p=0.226). However, the differences were not statistically significant. In the single-port group, the rate of conversion to multi-port VATS lobectomy was 11.5% (3 of 26). The rates of conversion to open thoracotomy in the triple-port and single-port groups were 7.7% and 3.8%, respectively (p=1.000). Conclusion: In comparison with the triple-port group, single-port VATS lobectomy showed similar results in safety and efficacy, indicating that single-port VATS lobectomy is a feasible and safe option for lung cancer patients.

Single-Port Video-Assisted Thoracic Surgery for Secondary Spontaneous Pneumothorax: Preliminary Results

  • Kim, Min-Seok;Yang, Hee Chul;Bae, Mi-Kyung;Cho, Sukki;Kim, Kwhanmien;Jheon, Sanghoon
    • Journal of Chest Surgery
    • /
    • v.48 no.6
    • /
    • pp.387-392
    • /
    • 2015
  • Background: The aim of this study was to evaluate the feasibility of single-port video-assisted thoracic surgery (VATS) in the treatment of secondary spontaneous pneumothorax (SSP). Methods: Twenty-four patients who were scheduled to undergo single-port VATS for SSP were studied. The medical records of the patients were retrospectively reviewed. The mean follow-up duration was $26.1{\pm}19.8$ months. In order to evaluate the feasibility of single-port VATS for SSP, the postoperative results of single-port VATS (n=15) in patients with emphysema were compared with those of emphysematous patients who underwent three-port VATS (n=15) during the study period. Results: Single-port VATS was feasible in 19 of 24 patients (79.2%), while an additional port was needed in five patients. In the single-port VATS patients, the median operation time, duration of chest tube drainage, and hospital stay were 84.0 minutes, one day, and two days, respectively. Postoperative complications included prolonged chest tube drainage for more than five days (n=1), wound infection (n=1), and vocal fold palsy (n=1). No recurrence of pneumothorax was observed during the follow-up period. The median operation time, duration of chest tube drainage, and hospital stay of the emphysematous patients who underwent single-port VATS were shorter than those who underwent three-port VATS group (p<0.05 for all parameters). Conclusion: Single-port VATS proved to be a feasible procedure in the treatment of patients with secondary spontaneous pneumothorax.

A four-port stripline circulator using a single ferrite disk (단일 페라이트 공진기를 이용한 4단자 스트립라인 서큘레이터)

  • Kim, Hye-Jin;Nam, Min-Hee;Lee, Jae-Hyun
    • Journal of Satellite, Information and Communications
    • /
    • v.4 no.2
    • /
    • pp.52-56
    • /
    • 2009
  • The design method of a four-port stripline circulator with a single ferrite disk is proposed using Green's function method. The four-port circulator gives the flexibility of the design of the communication system. Two cascaded three-port circulators has been used as a four-port circulator. However, if a four-port circulator with a single ferrite disk replace the present four-port circulator, then it will give less weight and volume and so has the advantage in satellite application.

  • PDF

Robotic harvest of a latissimus dorsi flap using a single-port surgical robotic system in breast reconstruction

  • Joo, Oh Young;Song, Seung Yong;Lew, Dae Hyun;Park, Hyung Seok;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.577-582
    • /
    • 2021
  • Robot-assisted surgery is evolving to incorporate a higher number of minimally invasive techniques. There is a growing interest in robotic breast reconstruction that uses autologous tissue. Since a traditional latissimus dorsi (LD) flap leads to a long donor scar, which can be an unpleasant burden to patients, there have been many attempts to decrease the scar length using minimally invasive approaches. This study presents the case of a patient who underwent a robot-assisted nipple-sparing mastectomy followed by immediate breast reconstruction with an LD flap using a single-port robotic surgery system. With the assistance of a single-port robot, a simple docking process using a short and less visible incision is possible. Compared to multiport surgery systems, single-port robots can reduce the possibility of collision between robotic arms and provide a clear view of the medial border of the LD where the curvature of the back restricts the visual field. We recommend the use of single-port robots as a minimally invasive approach for harvesting LD flaps.

Single-Port Transaxillary Robot-Assisted Latissimus Dorsi Muscle Flap Reconstruction for Poland Syndrome: Concomitant Application of Robotic System to Contralateral Augmentation Mammoplasty

  • Hwang, Yong-Jae;Chung, Jae-Ho;Lee, Hyung-Chul;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.373-377
    • /
    • 2022
  • Currently, robot-assisted latissimus dorsi muscle flap (RLDF) surgery is used in treating patients with Poland syndrome and for breast reconstruction. However, conventional RLDF surgery has several inherent issues. We resolved the existing problems of the conventional system by introducing the da Vinci single-port system in patients with Poland syndrome. Overall, three patients underwent RLDF surgery using the da Vinci single-port system with gas insufflation. In the female patient, after performing RLDF with silicone implant, augmentation mammoplasty was also performed on the contralateral side. Both surgeries were performed as single-port robotic-assisted surgery through the transaxillary approach. The mean operating time was 449 (335-480) minutes; 8.67 (4-14) minutes were required for docking and 59 (52-67) minutes for robotic dissection and LD harvesting. No patients had perioperative complication and postoperative problems related to gas inflation. The single-port robot-assisted surgical system overcomes the drawbacks of previous robotic surgery in patients with Poland syndrome, significantly shortens the procedure time of robotic surgery, has superior cosmetic outcomes in a surgical scar, and improves the operator's convenience. Furthermore, concurrent application to another surgery demonstrates the possibility in the broad application of the robotic single-port surgical system.

Role of Single Port Rigid Thoracoscopy in Undiagnosed Pleural Effusion

  • Jagdish Rawat;Anil Kumar;Parul Mrigpuri;Dev Singh Jangpangi;Abhay Pratap Singh;Ritisha Bhatt
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.194-199
    • /
    • 2024
  • Background: In recent years, medical thoracoscopy has been well established to play an important role in undiagnosed pleural effusion; however, this procedure is underutilized due to limited availability of the instruments it requires. This study analysed the outcome of single port rigid thoracoscopy in patients with undiagnosed pleural effusions. Methods: This study retrospectively analysed the outcomes of all patients with undiagnosed pleural effusion presenting to our centre between 2016 to 2020 who underwent single port rigid medical thoracoscopy as a diagnostic procedure. Results: In total, 92 patients underwent single port rigid medical thoracoscopy. The most common presenting symptom was shortness of breath. A majority of the patients had lymphocytic exudative pleural effusion. The average biopsy sample size was 18 mm, and no major complication was reported in any of the patients. Conclusion: Single port rigid thoracoscopy is a safe and well-tolerated procedure that yields a biopsy of a larger size with high diagnostic yield. Moreover, the low cost of the instruments required by this procedure makes it particularly suited for use in developing countries.

Three-Port Converters with a Flexible Power Flow for Integrating PV and Energy Storage into a DC Bus

  • Cheng, Tian;Lu, Dylan Dah-Chuan
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1433-1444
    • /
    • 2017
  • A family of non-isolated DC-DC three-port converters (TPCs) that allows for a more flexible power flow among a renewable energy source, an energy storage device and a current-reversible DC bus is introduced. Most of the reported non-isolated topologies in this area consider only a power consuming load. However, for applications such as hybrid-electric vehicle braking systems and DC microgrids, the load power generating capability should also be considered. The proposed three-port family consists of one unidirectional port and two bi-directional ports. Hence, they are well-suited for photovoltaic (PV)-battery-DC bus systems from the power flow viewpoint. Three-port converters are derived by combining different commonly known power converters in an integrated manner while considering the voltage polarity, voltage levels among the ports and the overall voltage conversion ratio. The derived converter topologies are able to allow for seven different modes of operation among the sources and load. A three-port converter which integrates a boost converter with a buck converter is used as a design example. Extensions of these topologies by combining the soft-switching technique with the proposed design example are also presented. Experiment results are given to verify the proposed three-port converter family and its analysis.

Situations and its Prospect of Single Window System for Customs One-Stop Service in Japan

  • Han, Sang-Hyun
    • The Journal of Information Technology
    • /
    • v.8 no.3
    • /
    • pp.143-158
    • /
    • 2005
  • The purpose of the paper is to analyze situations and its prospect of Single Window System for custom's one-stop service in Japan and to suggest effective application was to improve of in Korea's Customs systems. In response to the growing demand for lower trading costs and shorter and more predictable lead times with the advancement of the international trade supply chain, the Single Window System for import/export and port-related procedures was launched on 23 July 2003 in Japan. The concept of the Single Window System is to establish a comprehensive computer interface system that enables users to complete all import/export and port-related procedures required under different laws and regulations in a single input and single transmission. To realize the concept, the data elements and submission times of the various systems were harmonized, and manual procedures, such as quarantine and immigration, were computerized. Then, all the necessary systems, such as NACCS, Port EDI System, and Crew Landing Permit Support System, were interconnected as a Single Window System. Close cooperation among other governmental organizations and the private sector was a key factor in the successful development and smooth utilization of the System so that it fully met all parties' needs. It is anticipated that operating costs will be greatly reduced and trade facilitation will be enhanced as a result of the simplification of procedures. Korea Customs advocates the Single Window System as a best practice at ASEAN and WCO to contribute to the development of regional and international capacity building.

  • PDF

Single-Port Thoracic Surgery: A New Direction

  • Ng, Calvin S.H.
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.327-332
    • /
    • 2014
  • Single-port video-assisted thoracic surgery (VATS) has slowly established itself as an alternate surgical approach for the treatment of an increasingly wide range of thoracic conditions. The potential benefits of fewer surgical incisions, better cosmesis, and less postoperative pain and paraesthesia have led to the technique's popularity worldwide. The limited single small incision through which the surgeon has to operate poses challenges that are slowly being addressed by improvements in instrument design. Of note, instruments and video-camera systems that are narrower and angulated have made single-port VATS major lung resection easier to perform and learn. In the future, we may see the development of subcostal or embryonic natural orifice translumenal endoscopic surgery access, evolution in anaesthesia strategies, and cross-discipline imaging-assisted lesion localization for single-port VATS procedures.