• 제목/요약/키워드: Single Phase Full-Wave rectification X-ray equipment

검색결과 2건 처리시간 0.017초

진단용 X선장치의 성능 실태 조사연구 (A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications)

  • 선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

고정밀도의 단상전파정류형 X선 장치의 제작 및 평가 (Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision)

  • 한동균;정재은;최준구;성렬훈;고신관
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.413-419
    • /
    • 2011
  • 1950년대 진단용 X선 장치의 국산화가 이루어졌으며, 1960년 초부터 진단용 X선 장치의 수요가 급격히 증가함에 따라 생산업체의 증가로 의료기기 시장의 많은 발전을 가져왔다. 진단용 X선 장치는 방사선에 대한 인체의 위험 요소인 피폭문제가 있기 때문에 보건복지가족부가 제조, 설치기준을 제정하고 있으며, 이를 기본으로 하여 KSA 4019, KS A 4021, KS A 4022 등에 의해 정밀한 제작이 이루어지고 있다. 진단용 X선 발생장치는 단상 전파 정류형과 삼상 전파 정류형이 대부분이나, 1980년대 이후 인버터식 X선 발생장치로 대부분 전환되기 시작하였다. 인버터식 X선 발생장치는 단상 전파정류형 X선 발생장치에 비해 1.5~1.8배의 높은 출력과 단시간 제어가 정확하지만, 가격이 비싸기 때문에 개인병원에서는 단상전파정류형 X선 장치를 선호하고 있어 단상 전파정류형 X선 장치의 성능개선이 요구된다. 이에 본 연구자들은 단상 전파정류형 X선 발생장치의 제어장치, 고전압 변압기, 필라멘트 가열변압기, 정류회로, 고압케이블 등 기기의 구성요소를 제작하고 진단용 X선 발생장치의 성능평가를 시험하였으며, 그 결과 국내 규정인 진단용 방사선 발생장치의 안전관리 규칙에 적합한 기준을 얻을 수 있었다.