• Title/Summary/Keyword: Single IF output

Search Result 113, Processing Time 0.034 seconds

Design and Fabrication of the Transceiver with 400MHz Bandwidth (400 MHz 대역의 송수신기 설계 및 제작)

  • Hur Chang-Wu;Choi Jun-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.851-856
    • /
    • 2006
  • This paper studies about design of a transceiver using a single PLL. The transceiver has bandwidth of $424.7\sim424.95MHz$ and the communication method used 21 channels 12.5 KHz channel bandwidth and FSK modulation/demodulation method. Also, we designed low power wireless transceiver for data transmission using a single PLL. Finally, the transceiver set achieves the following characteristics : 8.15dBm output power, 45.97dBc spurious property.

Optimal Payment Contracts in Agent-Owner Relationship (대리인-선주간의 최적보상계약에 관한 연구)

  • 육근효
    • The Journal of Fisheries Business Administration
    • /
    • v.18 no.1
    • /
    • pp.37-57
    • /
    • 1987
  • This article discussed the characteristics of several Pareto-optimal incentive contracts between owner and labor, more specifically, four situations: reporting output jointly observable by labor ana owner; reporting both output and effort; incorporating other endogenous elements (like capital) that affect the production process and Pareto-optimal fee schedules; and ascertaining the effects of private pre-decision information private- decision information, and per-contact informational asymmetries. Also presented were several extensions of the basic contractual model, and the different components of agency costs associated with labor-owner contractual relations. In a single-period model, the agency problem exists because the uncertainty prevents the owner from using the cash flow to determine unambiguously the labor's action. Holmstrom(1979) suggests that "when the same situation repeats itself over time, the effects of uncertainty tend to be reduced and dystunctional behavior is more accurately revealed, thus alleviating the problem of moral hazard. " Under these conditions, if the labor selects the first-best level of effect in each period, the cash flow will be independent and identically distributed over time. As the number of periods increases, the variance of the labows average output, if he selects the first-best level of effort in each period, gets smaller. Note that for this diversification effect to occur, it is necessary that the owner evaluate the labor's effort over the entire history of his employment, rather than evaluate each period's performance separately. Radner(1980) and Rubinstein and Yaari(1980) consider the extreme case in which there are an infinite number of observations. They show that the owner can eventually detect and systematic shirking on the part of the labor by comparing the labor's average output with what would be expected if the labor had been selecting the first-best level of effort in each period. In a dynamic model with incentive problems we have demonstrated that the labor's second-period compensation will depend on his first-period performance. This allows the owner to diversify away some of the uncertainty surrounding the labor's actions. In addition, this allows the owner to smooth the labor's income over time by spreading the risk of the first-period outcome over both periods. At least some unexplored avenves in this area invite future accounting research: situations where owner has different incompatible objectives and negotiates a contract with labor; circumstances in which owner deals with multiple objectives and negotiates contracts with several labors simultaneously; the value of costly accounting information systems and communication in establishing, Pareto-optimal incentive contracts, and the value and effects of inside information, Thorough theoretical or empirical research on each of these topics not only would increase our knowledge about the role and significance of accounting information but could also provide explanations of the inherent differences among various organizations and in their economic behavior. behavior.

  • PDF

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

Test and Simulation of an Active Vibration Control System for Helicopter Applications

  • Kim, Do-Hyung;Kim, Tae-Joo;Jung, Se-Un;Kwak, Dong-Il
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.442-453
    • /
    • 2016
  • A significant source of vibration in helicopters is the main rotor system, and it is a technical challenge to reduce the vibration in order to ensure the comfort of crew and passengers. Several types of passive devices have been applied to conventional helicopters in order to reduce the vibration. In recent years, helicopter manufacturers have increasingly adopted active vibration control systems (AVCSs) due to their superior performance with lower weight compared with passive devices. AVCSs can also maintain their performance over aircraft configuration and flight condition changes. As part of the development of AVCS software for light civil helicopter (LCH) applications, a test bench is constructed and vibration control tests and simulations are performed in this study. The test bench, which represents the airframe, is excited using a pair of counter rotating force generators (CRFGs) and a multiple input single output (MISO) AVCS that consists of three accelerometer sensors and a pair of CRFGs; a filtered-x least mean square (LMS) algorithm is applied for the vibration reduction. First, the vibration control tests are performed with uniform sensor weights; then, the change in the control performance according to changes in the sensor weight is investigated and compared with the simulation results. It is found that the vibration control performance can be tuned through adjusting the weights of the three sensors, even if only one actuator is used.

System Level Performance Evaluation and Throughput Enhancement Algorithm of MBS (MBS의 전송률 증대 알고리즘 및 시스템 레벨 성능평가)

  • Seo, Seong-Young;Park, Dong-Chan;Kim, Suk-Chan;Kim, Young-Il
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.345-351
    • /
    • 2010
  • It has been growing interests that convergence services of broadcasting and telecommunication services such as DMB 2.0 and Mobile IPTV etc. Unicast type is difficult to service broadcasting due to limits of capacity and poor receiving environments, WiBro supports broadcast service with MBS. MBS is transmission method that base stations belong to same the MBS zone transmit the all users who request broadcasting service. Terminals are received resources from all base station in the MBS zone and SINR can be improved because of macro diversity. If terminals are located at edge of the MBS zone, complement algorithm are needed beacause received SINR is very low. In this paper, MIMO STBC, Relay and FFR are introduced to improve the throughputs using high MCS. The basic simulation environment is assumed to be SISO. Transparent relay and FFR applicable on MBS are divided by SISO and MIMO STBC environment and evaluate the performance.

Charge Copy Method for Reduction of Cross Regulation in SIDO Boost Converter (SIDO boost converter에서 크로스 레귤레이션을 줄이기 위한 전하 복사방법)

  • Hwang, Wonjune;Kim, Ju Eon;Baek, Kwang-Hyun
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.432-434
    • /
    • 2016
  • In conventional SIDO(Single Inductor Dual Output) boost converter, charging time is changed by load power consumption. In this case, if the power consumption of one load is changed to such a degree that switching frequency of the boost converter must be changed, another load charge time is also changed, which this causes cross regulation. In this paper, the charge copy technique is proposed to reduce cross regulation. When the switching frequency is changed to an integer ratio, another load charge time is also changed to integer ratio. Simulation result shows that proposed method reduces the 10.24mV cross regulation and 39.118us recover-time compared with conventional method.

Fuzzy Classifier System for Edge Detection

  • Sim, Kwee-Bo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.3 no.1
    • /
    • pp.52-57
    • /
    • 2003
  • In this paper, we propose a Fuzzy Classifier System(FCS) to find a set of fuzzy rules which can carry out the edge detection. The classifier system of Holland can evaluate the usefulness of rules represented by classifiers with repeated learning. FCS makes the classifier system be able to carry out the mapping from continuous inputs to outputs. It is the FCS that applies the method of machine learning to the concept of fuzzy logic. It is that the antecedent and consequent of classifier is same as a fuzzy rule. In this paper, the FCS is the Michigan style. A single fuzzy if-then rule is coded as an individual. The average gray levels which each group of neighbor pixels has are represented into fuzzy set. Then a pixel is decided whether it is edge pixel or not using fuzzy if-then rules. Depending on the average of gray levels, a number of fuzzy rules can be activated, and each rules makes the output. These outputs are aggregated and defuzzified to take new gray value of the pixel. To evaluate this edge detection, we will compare the new gray level of a pixel with gray level obtained by the other edge detection method such as Sobel edge detection. This comparison provides a reinforcement signal for FCS which is reinforcement learning. Also the FCS employs the Genetic Algorithms to make new rules and modify rules when performance of the system needs to be improved.

Speed Control of Three Phase Slotless PM BLDC Motor Using Single Sensor (Single Sensor를 이용한 3상 Slotless PM BLDC 전동기의 속도제어)

  • Lee S. J.;Yoon Y. H.;Woo M. S.;Won C. Y.;Choe Y. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.33-37
    • /
    • 2004
  • Slotless Permanent magnet Brushless DC Motor(PM BLDC) with the characteristics of high speed and high power density has been more widely used in industrial and automatic machine. Generally, PM BLDC meter is necessary that the three Hall-ICs evenly be distributed around the stator circumference in case of the 3 phase motor. The Hall-ICs are set up in this motor to detect the main flux from the rotor. therefore the output signal from Hall-ICs is used to drive a power transistor to control the stator winding current. However, instead of using three Hall-ICs, if only we used one Hall-IC, we estimate information of the others phase in sequence through a revolving rotor. This paper identified the characteristics and performance by using one Hall-IC for the 3 phase PM BLDC whose six stator and two rotor designed.

  • PDF

Development of Anti-windup Techniques for Cascade Control System (다단제어용 안티 와인드업 기술 개발)

  • Bae, Jeong Eun;Kim, Kyeong Hoon;Chu, Syng Chul;Heo, Jaepil;Lim, Sanghun;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.430-437
    • /
    • 2020
  • In this research, the anti-windup techniques for the cascade control system are newly developed. Cascade control system has an additional internal feedback control loop to reject disturbances better than the conventional control system. Remarkable difference between the conventional single-loop control system and the cascade control system is the interaction that the controller output saturation of the secondary control loop strongly affects the integral action of the primary control loop. In industry, local back calculation anti-windup method has been mainly used for each controller without considering the interaction between the two controllers. But it cannot eliminate the integral-windup of the primary controller originated from the saturation of the secondary controller output. To solve the problem, the two anti-windup techniques of the cascade conditional integration and the cascade back calculation are proposed in this research by extending the local anti-windup techniques for the single-loop control system to the cascade control system. Simulation confirmed that the proposed methods can effectively remove the integral windup of the primary controller caused by the saturation of the secondary controller output and show good control performances for various types of processes and controllers. If the reliability of the proposed methods is proved through the applications to real processes in the future, they would highly contribute to improving the control performances of the cascade control system in industry.

Design of Single Power CMOS Beta Ray Sensor Reducing Capacitive Coupling Noise (커패시터 커플링 노이즈를 줄인 단일 전원 CMOS 베타선 센서 회로 설계)

  • Jin, HongZhou;Cha, JinSol;Hwang, ChangYoon;Lee, DongHyeon;Salman, R.M.;Park, Kyunghwan;Kim, Jongbum;Ha, PanBong;Kim, YoungHee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.338-347
    • /
    • 2021
  • In this paper, the beta-ray sensor circuit used in the true random number generator was designed using DB HiTek's 0.18㎛ CMOS process. The CSA circuit proposed a circuit having a function of selecting a PMOS feedback resistor and an NMOS feedback resistor, and a function of selecting a feedback capacitor of 50fF and 100fF. And for the pulse shaper circuit, a CR-RC2 pulse shaper circuit using a non-inverting amplifier was used. Since the OPAMP circuit used in this paper uses single power instead of dual power, we proposed a circuit in which the resistor of the CR circuit and one node of the capacitor of the RC circuit are connected to VCOM instead of GND. And since the output signal of the pulse shaper does not increase monotonically, even if the output signal of the comparator circuit generates multiple consecutive pulses, the monostable multivibrator circuit is used to prevent signal distortion. In addition, the CSA input terminal, VIN, and the beta-ray sensor output terminal are placed on the top and bottom of the silicon chip to reduce capacitive coupling noise between PCB traces.