• Title/Summary/Keyword: Single Cycle

Search Result 1,045, Processing Time 0.023 seconds

Study on the Variation of Energy Dissipation Factor of Reinforced Concrete Beam under Cyclic Loading (반복하중을 받는 철근콘크리트 보의 에너지소산계수 변화 특성 고찰)

  • Suk-Hyeong Yoo;Dae-Young Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.86-93
    • /
    • 2023
  • As the hysteretic behavior of reinforced concrete members under cyclic loading progresses, the energy dissipation ability decreases due to a decrease in stiffness and strength and pinching effects. However, the guideline "Nonlinear Analysis Model for Performance-Based Seismic Design of Reinforced Concrete Building Structures, 2021" requires calculating a single energy dissipation factor for each member and all histeric step, so the decrease in energy dissipation capacity according to histeric step cannot be considered. It is judged that Therefore, in this study, the energy dissipation factor according to the histeric step was examined by comparing the existing experimental results and the nonlinear time history analysis results for a general beam under cyclic loading. The energy dissipation factor was calculated as the ratio of the energy dissipation amount of the actual specimen to the energy dissipation amount of the idealized elastoplastic behavior obtained as a result of nonlinear time history analysis. In the existing experiment results, the energy dissipation factor was derived by calculating one cycle for each histeric step, and the energy dissipation factor was derived based on the nonlinear modeling process in the guidelines. In the existing experimental study, the energy dissipation factor was calculated by setting each histeric step (Y-L-R), and the energy dissipation factor was found to be 0.36 in the Y-L step and 0.28 in the L-R step, and the energy dissipation factor in the guideline was found to be 0.31. This shows that the energy dissipation factor calculation formula in the guidelines does not indicate a decrease in the energy dissipation capacity of reinforced concrete members.

Spore PCR and qPCR Methods for Rapid Detection of Five Colletotrichum Species Responsible for Pepper Anthracnose in Korea (한국의 고추 탄저병을 일으키는 Colletotrichum 5종의 신속한 검출을 위한 포자 PCR 및 qPCR 방법)

  • Haejun Jeong;Jonghan Yoon;Hoyoung Park;Min Son;Sook-Young Park;Kwang-Hyung Kim
    • Research in Plant Disease
    • /
    • v.30 no.3
    • /
    • pp.219-228
    • /
    • 2024
  • Pepper anthracnose, caused by Colletotrichum spp., leads to a decrease in the quantity of pepper fruit production. Molecular diagnosis is crucial for rapid identification of pathogens and determination of fungicide resistance. However, the traditional process of isolating the pathogen, extracting genomic DNA, and analyzing the gene sequence is time-consuming, which delays rapid diagnosis. In this study, we introduced a method using conidia of Colletotrichum spp. instead of genomic DNA, eliminating the need for DNA extraction or special processing for diagnosis. To elucidate this method, sensitivity was assessed through polymerase chain reaction (PCR) and quantitative real-time PCR (qPCR) tests using internal transcribed spacer-based primer pairs. Both PCR and qPCR tests showed that detection is feasible with just one conidia, with over 1,000 conidia yielding results comparable to approximately 1 pg of genomic DNA. For amplifying the cytochrome b gene for quinone-outside inhibitor fungicide susceptibility testing, detection from a single conidium is achievable, but a stable PCR product is obtained by increasing the number of cycles to 35. Additionally, the addition of 10% grinding fresh chili pepper paste to V8-Juicea gar medium, which is known for inducing conidia rapidly from the isolates, resulted in 3.2 to 6.0 times more conidia compared to the commonly used potato dextrose agar medium, enhancing the potential for swift testing. Taken together, this study presents a direct utilization of pepper anthracnose conidia through PCR or qPCR, offering a valuable technique for amplifying target genes, such as the minimum conidial amount and barcode genes, for molecular identification of anthracnose disease in pepper through PCR and qPCR analysis.

Superovulation Response and Quality of Embryos Recovered from Cattle after a Single Subcutaneous Injection of FSH Dissolved in Polyethylene Glycol (PEG 융해 FSH 투여방법에 따른 소 과배란 유기 및 수정란이식 효율)

  • 최상용;최수호;박용수;조상래;강태영
    • Journal of Embryo Transfer
    • /
    • v.17 no.1
    • /
    • pp.67-77
    • /
    • 2002
  • This study was carried out to assess the effect of superovulation response and quality of embryos recovered from donor cows after a single subcutaneous injection of FSH dissolved in polyethylene glycol (PEG). Cows were allocated into control and 3 experimental treatment groups. In control, cows were injected intramuscularly 50 mg FSH twice daily for 4 days. Group 1 were injected subcutaneously with a single dose of 400 mg FSH dissolved in 30% PEG solution. Group 2 were injected subcutaneously with a single dose of 200 mg FSH dissolved in 30% PEG solution. Finally in group 3, cows were injected twice 200 mg FSH dissolved in 30% PEG solution by subcutaneous. Superovulation was initiated by injection of FSH between Day 8 and 14 of the estrus cycle (Day 0, the day of estrus), and followed by injection of 25 mg PGF$_2$$\alpha$ at 48 h after first FSH injection. Cows were then artificially inseminated (AI) with semen twice at 48 and 60 h after PGF$_2$$\alpha$ injection. At 7 days after the second AI, embryos collected non-surgically by flushing the uterine horns and were counted and compared morphologically as being transferable and degenerated among different superovulation treatments. Furthermore, progesterone and estradiol -17 $\beta$ in plasma were measured by radioimmunoassay following different treatments at given days All cows of treated groups were observed heat. but control group was showed 77.8%. Superovulation response was observed as 77.8, 87.5, 88.9, and 100% in control, Groups 1, 2 and 3 The mean number of corpus lutea (CL) detected in Group 1 were 19.6, which was, respectively significantly (P<0.05) higher than those of other groups (11.1, 13.4 and 7.6, respectively). However, there did not differ on the mean number of total embryos recovered and of transferable embryos between control and treated groups.

Field Crop Classification Using Multi-Temporal High-Resolution Satellite Imagery: A Case Study on Garlic/Onion Field (고해상도 다중시기 위성영상을 이용한 밭작물 분류: 마늘/양파 재배지 사례연구)

  • Yoo, Hee Young;Lee, Kyung-Do;Na, Sang-Il;Park, Chan-Won;Park, No-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_2
    • /
    • pp.621-630
    • /
    • 2017
  • In this paper, a study on classification targeting a main production area of garlic and onion was carried out in order to figure out the applicability of multi-temporal high-resolution satellite imagery for field crop classification. After collecting satellite imagery in accordance with the growth cycle of garlic and onion, classifications using each sing date imagery and various combinations of multi-temporal dataset were conducted. In the case of single date imagery, high classification accuracy was obtained in December when the planting was completed and March when garlic and onion started to grow vigorously. Meanwhile, higher classification accuracy was obtained when using multi-temporal dataset rather than single date imagery. However, more images did not guarantee higher classification accuracy. Rather, the imagery at the planting season or right after planting reduced classification accuracy. The highest classification accuracy was obtained when using the combination of March, April and May data corresponding the growth season of garlic and onion. Therefore, it is recommended to secure imagery at main growth season in order to classify garlic and onion field using multi-temporal satellite imagery.

Analysis of receptor like kinase (RLK) gene to stress in rice (Oryza sativa L.) using real-time PCR (Real-time PCR을 이용한 스트레스에 따른 벼의 Receptor like kinase (RLK) 유전자의 발현 변화 분석)

  • Kang, Min-Hee;Kim, Il-Wook;Han, Sang-Hoon;Yun, Choong-Hyo;Yoon, Byoung-Su
    • Journal of Plant Biotechnology
    • /
    • v.35 no.4
    • /
    • pp.281-290
    • /
    • 2008
  • In plant, Receptor-like kinases (RLKs) are protein family, though its function is not yet understood, consisted of a predicted signal sequence, single transmembrane region, and cytoplasmic kinase domain. RLKs are involved in hormonal response pathways, cell differentiation, plant growth and development, self-incompatibility, and symbiont and pathogen recognition. In this study, expression levels of RLG1, RLG5, RLG6, RLG#6, RLG8, RLG10, RLG17, RLG18 and RLG20 were analyzed by Real-time PCR, when rice (Oryzae sativa) was treated abiotic stress. The expression levels of all RLGs were compared each other by analyzed value of threshold cycles ($C_T$). Consequently, RLGs were suppressed by NaCl as salinity stress, and expression of each RLK genes were showed difference treated salicylic acid and wound, respectively. However, All RLGs were induced under low temperature condition. Therefore, our results indicate protection-function of RLK genes to be an early response of rice against cold weather.

The Design of Single Phase PFC using a DSP (DSP를 이용한 단상 PFC의 설계)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.57-65
    • /
    • 2007
  • This paper presents the design of single phase PFC(Power Factor Correction) using a DSP(TMS320F2812). In order to realize the proposed boost PFC converter in average current mode control, the DSP requires the A/D sampling values for a line input voltage, a inductor current, and the output voltage of the converter. Because of a FET switching noise, these sampling values contain a high frequency noise and switching ripple. The solution of A/D sampling keeps away from the switching point. Because the PWM duty is changed from 5% to 95%, we can#t decide a fixed sampling time. In this paper, the three A/D converters of the DSP are started using the prediction algorithm for the FET ON/OFF time at every sampling cycle(40 KHz). Implemented A/D sampling algorithm with only one timer of the DSP is very simple and gives the autostart of these A/D converters. From the experimental result, it was shown that the power factor was about 0.99 at wide input voltage, and the output ripple voltage was smaller than 5 Vpp at 80 Vdc output. Finally the parameters and gains of PI controllers are controlled by serial communication with Windows Xp based PC. Also it was shown that the implemented PFC converter can achieve the feasibility and the usefulness.

Optimization of Resistance Spot Weld Condition for Single Lap Joint of Hot Stamped 22MnB5 by Taking Heating Temperature and Heating Time into Consideration (핫스템핑 공정에서 가열온도 및 유지시간을 고려한 22MnB5의 단일겹치기 저항 점용접 조건 최적화)

  • Choi, Hong-Seok;Kim, Byung-Min;Park, Geun-Hwan;Lim, Woo-Seung;Lee, Sun-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1367-1375
    • /
    • 2010
  • In this study, optimization of the process parameters of the resistance spot welding of a sheet of aluminum-coated boron alloyed steel, 22MnB5, used in hot stamping has been performed by a Taguchi method to increase the strength of the weld joint. The process parameters selected were current, electrode force, and weld time. The heating temperature and heating time of 22MnB5 are considered to be noise factors. It was known that the variation in the thickness of the intermetallic compound layer between the aluminum-coated layer and the substrate, which influences on the formation of nugget, was generated due to the difference of diffusion reaction according to heating conditions. From the results of spot weld experiment, the optimum weld condition was determined to be when the current, electrode force, and weld time were 8kA, 4kN, and 18 cycles, respectively. The result of a test performed to verify the optimized weld condition showed that the tensile strength of the weld joint was over 32kN, which is considerably higher than the required strength, i.e., 23kN.

Simplified Approximation Method of the Multi-Compartments Model on the Migration of Contaminant through Unsaturated Zone (불포화대에서 오염물질 이동현상에 대한 다중구획 모델의 단순 근사방법)

  • Cheong, Jae-Hak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.29-37
    • /
    • 2007
  • A conventional single compartment model cannot simulate reasonably the migration phenomenon of contaminants through unsaturated zone, due to the intrinsic unrealistic assumption of the compartment model that contaminants entering a compartment are immediately and uniformly mixed. Although, a multi-compartments model, in which even physically identical layer is divided into multiple compartments, may be used for explaining the retardation of contaminant mass flux along with increasing number of compartments, its numerical modeling is usually time-consuming and appropriate analytical solutions have not been reported yet. In order to improve the conventional compartment models on contaminant migration through unsaturated zone, a series of analytical solutions for multi-compartments model were derived and a generalized constraint under which the results from multi-compartments model can be simply approximated by single compartment model was proposed. The simplified approximation method was verified by a simple numerical analysis on the constraint under hypothetical conditions. It was also proved that the influent contaminant transfer rate from the bulk unsaturated zone can be generally represented into a time-dependent nominal transfer rate rather than a constant. In addition, the nominal transfer rate turned out to be very sensitive to the contaminant transfer rate between compartments in unsaturated zone, but to be almost insensitive to the transfer rate from contaminated zone. It is expected that the simplified approximation method developed in this study can be used for rapid and reasonable estimation of the migration phenomenon of contaminant through unsaturated zone, instead of time-consuming multi-compartments modeling.

  • PDF

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

Cost-effective assessment of filter media for treating stormwater runoff in LID facilities (비용 효율적 강우유출수 처리를 위한 LID시설의 여재 평가)

  • Lee, Soyoung;Choi, Jiyeon;Hong, Jungsun;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.194-200
    • /
    • 2016
  • The impervious surface rate increased by urbanization causes various problems on the environment such as water cycle distortion, heat island effect, and non-point pollutant discharges. The Low Impact Development (LID) techniques are significantly considered as an important tool for stormwater management in urban areas and development projects. The main mechanisms of LID technologies are hydrological and environmental pollution reduction among soils, media, microorganisms, and plants. Especially, the media provides important functions on permeability and retention rate of stormwater runoff in LID facilities. Therefore, this research was performed to assess the pollutant removal efficiency for different types of media such as zeolite, wood chip, bottom ash, and bio-ceramic. All media show high pollutant removal efficiency of more than 60% for particulate materials and heavy metals. Double layered media is more effective in reducing heavy metals by providing diverse sizes of micro-pores and macro-pores compared to the single layered media. The results recommend the use of different sizes of media application is more cost-effective in LID than a single size of media. Furthermore, soluble proportion of total heavy metal in the stormwater is an important component in proper media selection and arrangement.