• Title/Summary/Keyword: Simultaneous quantitation

Search Result 69, Processing Time 0.03 seconds

Analytical Method of Multi-Preservatives in Cosmetics using High Performance Liquid Chromatography (HPLC 를 이용한 화장품 중 살균보존제 다성분 동시분석법 연구)

  • Min-Jeong, Lee;Seong-Soo, Kim;Yun-Jeong, Lee;Byeong-Chul, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.321-330
    • /
    • 2022
  • This study attempted to establish an optimal multi-compound simultaneous analysis method that can secure reliable results for 15 - preservatives, 2 - sun screens and 1 - antioxidants of cosmetics using HPLC-PDA. Since the potential of hydrogen (pH) in the mobile phase affects the acid dissociation constant (pKa) of the preservatives, and the peak retention time shift and area change were observed. The peak separation condition was established by adjusting the pH to 0.1% H3PO4 addition (mL) when preparing the mobile phase. As a results of method validation, the linearity correlation coefficient (R2) of above 0.999 were obtained, and accuracy 87.9 ~ 101.1%, 0.1 ~ 7.6% precision for two types of cosmetics (cream and shampoo). It was found that the limit of detection (LOD) was 0.1 ~ 0.2 mg/kg and the limit of quantitation (LOQ) was 2.0 ~ 4.0 mg/kg. In addition, it was possible to simultaneously separate p-anisic acid, a natural compound that was difficult to separate in HPLC due to the small difference from methylparaben, a synthetic preservatives. Through this study, it will be effectively used to secure quality control and safety for compound that need restrictions on use cosmetics.

Development of Simultaneous Analysis for Multiple Agricultural Pesticides in Raw Milk Products using GC-MS/MS (GC-MS/MS를 이용한 원유 원료 중 농약 동시분석법 확립)

  • Young Nae Choi;Yoon ho Shin;Hwangeui Cho;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.420-429
    • /
    • 2023
  • GC-MS/MS using liquid-liquid extraction (LLE) and C18 cartridges was used to identify and quantify levels of chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin and permethrin in bulk raw milk. A calibration curve spanning 10 ng/mL to 200 ng/mL was obtained with a satisfactory correlation coefficient of 0.99. The limits of detection (LOD) and limits of quantitation (LOQ) for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in the matrix ranged from 0.06 to 1.81 ng/mL and 0.19 to 6.04 ng/mL, respectively. The recoveries of 5 pesticides from spiked samples at 37.5-125 ng/mL ranged from 86.1 to 102.1%. The measurement of uncertainty of the GC-MS/MS method for these five pesticides was developed based on the analytical process and quantification. An analysis method that is easier and faster than the method specified in the Korean food standards codes for analyzing these five pesticides in raw material milk was developed. Moreover, the analytical method for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in bulk raw milk by GC-MS/MS was established.

Simultaneous Pesticide Analysis Method for Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor and Trifluralin Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor 및 Trifluralin의 동시 분석)

  • Ahn, Kyung Geun;Kim, Gi Ppeum;Hwang, Young Sun;Kang, In Kyu;Lee, Young Deuk;Choung, Myoung Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.104-116
    • /
    • 2018
  • BACKGROUND: This experiment was conducted to establish a simultaneous analysis method for 7 kinds of herbicides in 3 different classes having similar physicochemical property as diphenyl ether(bifenox and oxyfluorfen), dinitroaniline (ethalfluralin and trifluralin), and chloroacetamide (metolachlor, pretilachlor, and thenylchlor) in crops using GC-ECD/MS. METHODS AND RESULTS: All the 7 pesticide residues were extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice and soybean. The extract was diluted with saline water and directly partitioned into n-hexane/dichloromethane(80/20, v/v) to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. The analytes were separated and quantitated by GLC with ECD using a DB-1 capillary column. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop samples fortified with bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries of the 7 pesticide residues ranged from 75.7 to 114.8% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of the analytes were 0.004 (etahlfluralin and trifluralin), 0.008 (metolachlor and pretilachlor), 0.006 (thenylchlor), 0.002 (oxyfluorfen), and 0.02 (bifenox) mg/kg as verified by the recovery experiment. A confirmatory technique using GC/MS with selected-ion monitoring was also provided to clearly identify the suspected residues. Therefore, this analytical method was reproducible and sensitive enough to determine the residues of bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin in agricultural commodities.

Simultaneous Analysis Method of BPA, BPF, BADGE, BFDGE and Their Degradation Products in Canned Foods and Food Simulants by HPLC (HPLC를 이용한 캔 식품 및 식품 유사용매 중 BPA, BPF, BADGE, BFDGE 및 분해산물의 동시분석법)

  • Choi, Jae-Chun;Kyung, Suk-Hun;Lee, Gun-Tack;Lee, Kwang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.174-179
    • /
    • 2002
  • A simple and sensitive analysis method based on reverse phase (RP) HPCL with flourescence detector was developed for simultaneous determination of bisphenol A (BPA), bisphenol F (BPF), bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE), and their degradation products, $BADGE{\cdot}H_2O$, $BADGE{\cdot}2H_2O$, $BFDGE{\cdot}H_2O$, $BFDGE{\cdot}2H_2O$, $BADGE{\cdot}HCl{\cdot}H_2O$, $BADGE{\cdot}HCl$, $BADGE{\cdot}2HCl$, $BFDGE{\cdot}HCl{\cdot}H_2O$, $BFDGE{\cdot}HCl$ and $BFDGE{\cdot}2HCl$, which were hydrolyzed and chlorinated forms of BADGE and BFDGE, in canned foods and food simulants. These compounds were identified by GC/MSD with $MSTFA-NH_4I-DTE$ derivatization. Recovery study was performed at each 100 ng/mL levels of BPA, BPF, BADGE and BFDGE added to canned foods and food simulants. This method was resulted in recovery of $90{\sim}114%$ with relative standard deviation of $4.1{\sim}7.0%$, detection limits of $6{\sim}11$ ng/mL and quantitation limits of $12{\sim}18\;ng/mL$. Calibration curves were linear with correlatin coefficients of 0.997 for BPF, 0.996 for BPA, 0.9987 for BFDGE, and 0.9989 for BADGE.

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.

Development of Analytical Methods of Spinosad in Agricultural Commodities by HPLC with UV Detector and Monitoring (HPLC-UVD를 이용한 농산물 중 스피노사드 분석법 개선 및 잔류실태 조사)

  • Kim, Hee-Yun;Choi, Sun-Hee;Chung, So-Young;Choi, Hee-Ju;Kim, Yong-Hoon;Cho, Min-Ja;Seo, Eun-Chae;Han, Kyoung-Jin;Choi, Jae-Chun;Park, Hee-Ok;Ha, Sang-Chul;Shin, Il-Shik;Eom, Ji-Yoon
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.125-133
    • /
    • 2011
  • The purpose of this study was to develop a methodology to detect spinosad which are difficult to analyze by multi-component simultaneous analysis of pesticide residues. We monitored spinosad due to the paucity of related information. The spinosad was determined using HPLC with UV detector at 250 nm. Correlation coefficient ($r^2$) for standard curve of spinosad A and D at standard concentration of 0.1-5.0 mg/kg were 0.999, respectively. Limit of quantitation (LOQ) of HPLC analysis was 0.005 mg/kg while limit of detection (LOD) was 0.001 mg/kg. Recovery experiments were conducted on five representative agricultural products to validate the analytical method. The recovery of proposed methods ranged from 74.9% to 104.0% and relative standard deviations were less than 10%. Spinosad residues were investigated in 16 commodities collected from 22 provinces. In this study, residues on all samples were not detected.

Determination of the Levels of Bisphenol A Diglycidyl Ether (BADGE), Bisphenol F Diglycidyl Ether (BFDGE) and Their Reaction Products in Canned Foods Circulated at Korean Markets (캔 제품의 bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) 유도체 및 분해산물 분석법)

  • Kim, Hee-Yun;Lee, Jin-Sook;Cho, Min-Ja;Yang, Ji-Yeon;Baek, Ji-Yun;Cheong, So-Young;Choi, Sun-Hee;Kim, Young-Seon;Choi, Jae-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE) were obtained by a polymerization reaction of epichlorohydrin (ECH) with bisphenol A (BPA) or bisphenol F (BPF). These compounds are commonly used as monomers or additives such as a polymerization stabilizer and a hydrochloric acid scavenger of epoxy resin, polyvinyl chloride (PVC)-containing organosols and polyester lacquers, that are applied to the internal surface of most canned foods to impart chemical resistance. The unreacted BADGE, BFDGE and their reaction products migrating from epoxy resin, PVC-containing organosol and/or polyester lacquer-based food packaging materials into the foods have recently become an issue of great concern because of increased customer demand for safety. This study was conducted to develop a rapid and sensitive simultaneous analysis method based on HPLC/FLD and HPLC/APCI-mass and to evaluate the concentration of BADGE, BFDGE and their metabolites, BADGE $H_2O$, BADGE $2H_2O$, BADGE HCl, BADGE 2HCl, BADGE HCl $H_2O$, BFDGE $H_2O$, BFDGE $2H_2O$, BFDGE HCl, BFDGE 2HCl and BFDGE HCl $H_2O$ for 133 canned food samples. The method provided a linearity of 0.9997-0.9999, a limit of detection of $0.01-0.13\;{\mu}g/mL$, a limit of quantitation of $0.03-0.44\;{\mu}g/mL$ and a recovery (%) of 85.64-118.18. The number of samples containing BADGE, BFDGE or their metabolites were: 28/133 (21.1%), with levels of 0.400-0.888 mg/kg being observed for aqueous foods (19/133) and 0.093-0.506 mg/kg being observed for oily foods (9/133).

Improvement of an Simultaneous Determination for Clenbuterol and Ractopamine in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 clenbuterol과 ractopamine의 동시 분석법 개선)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Young;Kim, Hyung-Soo;Kang, Ilhyun;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Kisung;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • Clenbuterol and ractopamine, which are ${\beta}$-agonists, have been misused as a growth promoting agent in meat producing animals. Clenbuterol was banned for veterinary drug in Korea because of its problems regarding safety. Due to their adverse effects, such as cardiovascular and central nervous diseases on human health proper control and monitoring should be conducted. The existing analytical method of clenbuterol and ractopamine in the Food code was improved through our present study. The bovine muscle samples were subjected to enzymatic hydrolysis, extracted with ethyl acetate and defatted by hexane-methanol partitioning. A molecular imprinted polymer (MIP) solid phase extraction cartridge was used for clean-up and LC-MS/MS was operated in positive multiple reaction monitoring (MRM). Clenbuterol-$d_9$ and ractopamine-$d_3$ were used as an internal standard. The renewed method was validated according to the CODEX guideline. The limits of quantitation for clenbuterol and ractopamine were 0.2 and 0.5 ${\mu}g/kg$, respectively. The mean recoveries ranged in 104.2-113.5% for clenbuterol and in 107.6-118.1% for ractopamine. The improved method was able to save both time and expenses.