• Title/Summary/Keyword: Simultaneous multiple focusing

Search Result 18, Processing Time 0.063 seconds

Theoretical Development and Experimental Investigation of Underwater Acoustic Communication for Multiple Receiving Locations Based on the Adaptive Time-Reversal Processing (다중수신 수중음향통신을 위한 적응 시계열반전처리 기법의 이론연구와 실험적 검증)

  • Shin Kee-Cheol;Byun Yang-Hun;Kim Jea-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.239-245
    • /
    • 2006
  • Time-reversal processing (TRP) has been shown as an effective way to focus in both time and space. The temporal focusing properties have been used extensively in underwater acoustics communications. Recently. adaptive time-reversal processing (ATRP) was applied to the simultaneous multiple focusing in an ocean waveguide. In this study. multiple focusing with ATRP is extended to the underwater acoustic communication algorithm for multiple receiving locations. The developed algorithm is applied to the underwater acoustic communication to show, via simulation and real data, that the simultaneous self-equalization at multiple receiving locations is achieved.

Ultrasound Imaging Based On Simultaneous Multiple Transmit Focusing Using Orthogonal Modified Golay Code (직교하는 변형된 골레이(Golay) 코드를 이용한 동시 다중 집속 기반의 초음파 영상 기법)

  • Kim, B.H.;Jeong, Y.K.;Song, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.187-190
    • /
    • 2001
  • A new ultrasound imaging technique based on simultaneous multiple transmit focusing using orthogonal modified Golay codes is presented. modified Golay codes are used to increase signal-to-noise-ratio(SNR) and maximize the transmit power efficiency(TPE). Conventional Golay codes consist of a pair of complementary codes with same length and can be compressed into a delta-like signal due to their complementary property. In the present work, two modified Golay codes focused at different depths are transmitted at the same time, which are mutually orthogonal. On receive, these orthogonal modified Golay codes are separately compressed into two short pulses and individually focused. These two focused beam are combined to form a frame of image with improved lateral resolution. Computer simulations are performed to verity the proposed method improves the lateral resolution of image compared with the conventional echo system.

  • PDF

Gram-Schmidt process based adaptive time-reversal processing (그람슈미트 과정 기반의 적응형 시역전 처리)

  • Donghyeon Kim;Gihoon Byun;J. S. Kim;Kee-Cheol Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.184-199
    • /
    • 2024
  • Residual crosstalk has been considered as a major drawback of conventional time-reversal processing in the case of simultaneous multiple focusing. In this paper, the Gram-Schmidt process is applied to time-reversal processing to mitigate crosstalk in ocean waveguides for multiple probe sources. Experimental data-based numerical simulations confirm that nulls can be placed at multiple locations, and it is shown that different signals can be simultaneously focused at different probe source locations, ensuring distortionless responses in terms of active time-reversal processing. This focusing property is also shown to be much less affected by a reduction in the number of receivers than the adaptive time-reversal mirror method. The proposed method is shown to be effective in eliminating crosstalk in passive multi-input multi-output communications using sea-going data.

Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach (동시 다중 주사 방식의 초음파 합성구경 빔포머 구조)

  • Lee, Yu-Hwa;Kim, Seung-Soo;Ahn, Young-Bok;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.803-810
    • /
    • 2007
  • Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.

Simultaneous Multiple Transmit Focusing Using Orthogonal Weighted Linear FM Chirp (가중된 직교 선형 FM신호를 이용한 송신 동시 다중 빔집속 기반의 초음파 영상 기법)

  • 정영관;송태경
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.155-158
    • /
    • 2001
  • A new method for simultaneous multiple transmit focusing using orthogonal weighted FM chirp is proposed. Weighted chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in the approximate sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels, and the crosscorrellation function of any pair of the signals has smaller values than the sidelobe levels of each autocorrelation function. This means that each weighted chirp signal can be separately compressed into a short pulse, focused individually and combined with other focused beams to form a frame of image. Theoretically, any two chirp signals defined in two nonoverlapped frequency bands are mutually orthogonal. In the present work, however, a fractional overlap of adjacent frequency bands, by up to 25%, were permitted to design more chirp signals within a given transducer bandwidth. The crosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals. The simulation results show that this method can improve the lateral resolution of image without sacrifice in the frame rate compared with the conventional pulse system.

  • PDF

Multiple Transmit Focusing Method With Modified Orthogonal Golay Codes for Ultrasound Imaging (초음파 영상에서 변형된 직교 골레이 코드를 이용한 동시 다중 송신 집속 기법)

  • 김배형;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.217-231
    • /
    • 2003
  • Coded excitation with complementary Golay sequences is an effective means to increase the SNR and penetration of ultrasound imaging. in which the two complementary binary codes are transmitted successively along each scan-line, reducing the imaging frame rate by half. This method suffers from low frame rate particularly when multiple transmit focusing is employed, since the frame rate will be further reduced in proportion to the number of focal zones. In this paper. a new ultrasound imaging technique based on simultaneous multiple transmit focusing using modified orthogonal Golay codes is proposed to improve lateral resolution with no accompanying decrease in the imaging frame rate, in which a pair of orthogonal Golay codes focused at two different focal depths are transmitted simultaneously. On receive, these modified orthogonal Golay codes are separately compressed into two short pulses and individually focused. These two focused beams are combined to form a frame of image with improved lateral resolution. The Golay codes were modified to improve the transmit power efficiency (TPE) for practical imaging. Computer simulations and experimental results show that the proposed method improves significantly the lateral resolution and penetration of ultrasound imaging compared with the conventional method.

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Effect of Vertically Travelling Fires on the Collapse of Tall Buildings

  • Kotsovinos, Panagiotis;Jiang, Yaqiang;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.49-62
    • /
    • 2013
  • Many previous tall building fires demonstrate that despite code compliant construction fires often spread vertically and burn over multiple floors at the same time. The collapses of the WTC complex buildings in 9/11 as well as other partial collapses like the ones of the Windsor Tower in Madrid and of the Technical University of Delft building posed new questions on the stability of tall buildings in fire. These accidents have shown that local or global collapse is possible in multi-floor fires. In most of the previous work involving multi-floor fires all floors were assumed to be heated simultaneously although in reality fires travel from one floor to another. This paper extends previous research by focusing on the collapse mechanisms of tall buildings in fire and performs a parametric study using various travelling rates. The results of the study demonstrate that vertically travelling fires have beneficial impact in terms of the global structural response of tall buildings in comparison to simultaneous fires. Contrary to the beneficial effect of the travelling fires in terms of the global structural response, it was noticed that higher tensile forces were also present in the floors compared to simultaneous multi-floor case. Designers are therefore advised to consider simultaneous multi-floor fire as an upper bound scenario. However, a scenario where a travelling fire is used is also suggested to be examined, as the tensile capacity of connections may be underestimated.

Validity of MAST-CLA for diagnosis of arthropod allergy using receiver operating characteristic (ROC) analysis

  • Park, Joon-Soo;Nam, Hae-Seon;Kim, Yong-Bae;Choi, Young-Jin;Lee, Sang-Han;Kim, Sung-Ho
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.3
    • /
    • pp.239-243
    • /
    • 2007
  • Many allergists are currently focusing on the development of new diagnostic tools, and are attempting to improve both the sensitivity and specificity. A multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is one of the most popular diagnostic tools used in the Republic of Korea. However, there remains controversy among allergists with regard to the cut-off point for a positive result. The present study was conducted in order to determine the validity of MAST-CLA as compared with that of the skin prick test, with particular emphasis on arthropod allergens, on the basis of percentage agreement rates and k-values, and also to suggest the optimal positive cutoff points using receiver operating characteristic (ROC) curves. The study was conducted with 97 subjects (54 men, 43 women). Optimal individual cut-off points were calculated as follows; class II for Dermatophagoides farinae, class I for Dermatophagoides pteronyssinus, and trace for a cockroach mix. These findings suggest that attempting to apply optimal individual cut-off points will be a good way of improving diagnostic tests, particularly MAST-CLA.

Recent Progress in Multiplexed Detection of Biomarkers Based on Quantum Dots (양자점 기반 다중 바이오마커 검출법의 연구동향)

  • Kim, Yerin;Choi, Yu Rim;Kim, Bong-Geun;Na, Hyon Bin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.451-458
    • /
    • 2022
  • Semiconductor quantum dots (QDs) are optical probes with excellent fluorescence properties. Therefore, they have been applied to various bio-medical imaging techniques and biosensors. Due to the unique optical characteristics of wide absorption and narrow fluorescence energy bands, multiple types of signals can be generated by the combination of fluorescence wavelengths from different QDs, which enables the simultaneous detection of more than two biomarkers. In this review, the advantages and applications of QDs and QD nanobeads (QBs) in multiple biomarker assays were described, and new developments or improvements in multiplexed biomarker detection techniques were summarized. In particular, recent reports were summarized, focusing on the design strategies in immunoassay construction and signal transducing materials for fluorescence-linked immunosorbent assays using QDs and immunochromatographic assays using QBs. New detection platforms will be developed for early diagnosis of diseases and other fields if multiplexed detection technologies of excellent accuracy and sensitivity are combined with artificial intelligence algorithms.